Loading...
HomeMy WebLinkAbout626 SYCAMORE STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2025 02/28/2025 2025-00000249 $80.00 Customer #: 24658 PRYME TYME 626 SYCAMORE ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 626 SYCAMORE ST - 12-19-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24658 01/27/2025 02/28/2025 2025-00000249 $80.00 Less Prepayment Total Due —� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT PRYME TYME, 626 SYCAMORE ST, BLDG 626 SYCAMORE ST, WATERLOO /A 50703 DETAILS Inspection Date: 12/19/2024 I Inspection Type: Annual Inspec n (1Y I Inspection Numbr: 813 I Shift: NJA I Station: N/A Unit: N/A j Lead Inspector: JEFF SIEBEL I Other Inspectors: ee: $80.00 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 23 ( Violations: 12 I N/A Codes: 39 STATUS CODE DESCRIPTION FAIL 1004.9 - Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load load. of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. Location: near front door Original Comment: Post occupant load provided by fire department Printed on 12/192024 @ 13:27 Page 1 of 6 STATUS CODE DESCRIPTION FAI L FAI L 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch - pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Location: Required back exit Original Comment: Repair or Replace fire exit with permits and inspections. Door must unlatch and swing open with less than 15# force. Currently door will not operate at all. 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: Ceiling Original Comment: Repair or replace all egress lights including 3 on ceiling FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Front and Back Doors Original Comment: Repair or replace exit lights. Lights must illuminate when tested. Printed on 12/19/2024 @ 13:27 Page 2 of 6 STATUS CODE DESCRIPTION FAIL 5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Location: Entire Building Original Comment: Provide current annual fire sprinkler inspection report with all discrepancies corrected. Currently 338 days past due. Contractor must upload online to the compliance engine. FAIL 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. FAI L 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: 626 Sycamore Original Comment: Provide current keys for bussiness in knox-box for fire fighter access. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Back wall behind bar. Original Comment: replace missing outlet cover FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: TV Original Comment: remove extension cord. Power strip with manual reset may be utilized for light duty use such as TV's, computers etc but not coolers, freezers or heat producing devices. Printed on 12/19/2024 @ 13:27 Page 3of6 STATUS CODE DESCRIPTION FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Front window Christmas Tree Original Comment: Power strip with manual reset may be utilized for light duty use such as TV's, computers etc but not coolers, freezers or heat producing devices. FAIL 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: Not Provided Original Comment: temporary lights must be removed after 90 days. FAIL 705.2 - Inspection and Opening protectives in fire -resistance -rated assemblies shall be inspected and maintenance. maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. Location: adjoining space to coridoor to restrooms and exit from 626 Original Comment: Replace missing door. Check with building official regarding possible rating or permit requirements. Greg Ahlhelm 319-291-4319 Printed on 12/19/2024 @ 13:27 Page 4 of 6 STATUS CODE DESCRIPTION FAIL 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10- B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10-pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: Front and back of space Original Comment: Install 2 2A-10BC fire extinguishers 4" to 5' above the floor in accessible locations. If purchased attach reciept to bottom of fire extinguisher. GENERAL NOTES JEFF SIEBEL - 12/19/2024 @ 13:26 Call Inspector if all corrections completed early. JEFF SIEBEL - 12/19/2024 @ 13:08 annual inspection fee $80 Printed on 12/19/2024 @ 13:27 Page 5 of 6 GENERAL NOTES JEFF SIEBEL - 12/19/2024 @ 13:10 This inspection is for 626 Sycamore only. Any use or expansion of space other than 626 Sycamore will require an architect and approval from Building Official Greg Ahlhelm and Fire Inspector. REINSPECTION DATE 01/16/2025 CONTACT SIGNATURE Rodney Lewis Signed on: 12/19/2024 @ 13:20 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/19/2024 @ 13:21 QUESTIONS A/OUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 1..`-\___ iC acif) ( Printed on 12/19/2024 @ 13:27 Page 6 of 6