Loading...
HomeMy WebLinkAbout3628 KIMBALL AVE0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2025 02/28/2025 2025-00000251 $80.00 Customer #: 24657 R SMOKES PLUS 3628 KIMBALL AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 3628 KIMBALL AVE - 1-02-25 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24657 01/27/2025 02/28/2025 2025-00000251 $80.00 Less Prepayment Total Due —� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT R SMOKES PLUS, 3628 KIMBALL AVE, BLDG 3628 KIMBALL AVE, WATERLOO IA S0701 DETAILS Inspection Date: 01/02/2025 I Inspection Type: Annual Inspection (1Yr) j Inspection Number: 1138 I Shift: N/A j Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 16 I Violations: 9 I N/A Codes: 52 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: Not Provided Original Comment: Obtain permits and inspections for all electrical and building work completed without and any future work. Printed on 01/03/2025 @ 10:32 Page 1 of 7 STATUS FAI L CODE 1032.2 - Reliability. DESCRIPTION Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Location: Front door and aisles between display cases. Original Comment: Remove power cords from in front of front door and install electrical between display cases in accordance with electrical code . Printed on 01/03/2025 @ 10:32 Page 2 of 7 STATUS CODE DESCRIPTION FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. FAIL FAI L 308.1.5 - Location near combustibles. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Location: Back hall Original Comment: Remove obstructions to rear exit. No storage allowed. Open flames such as from candles, lanterns, kerosene heaters and gas -fired heaters shall not be located on or near decorative material or similar combustible materials. Location: Through out store Original Comment: Open flames (incense) prohibited near combustibles. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Behind counter Original Comment: remove multi -plug adapter and extension cords Printed on 01/03/2025 @ 10:32 Page 3 of 7 STATUS FAIL FAI L CODE 603.6 - Extension cords. 603.6 - Extension cords. DESCRIPTION Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind counter Original Comment: remove extension cords and install permanent power with proper permit and inspections. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: By front door Original Comment: Remove extension cords at front of store, including one crossing exit door. Cooler must plug directly into permanent permanent wall outlet with permits and inspections. Printed on 01/03/2025 @ 10:32 Page 4 of 7 STATUS FAIL CODE 603.9.4 - Prohibited areas. DESCRIPTION Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: Behind counter Original Comment: remove electric heater from building or provide documentation of manufactures listing for use in a commercial setting and proper clearances. Printed on 01/03/2025 @ 10:32 Page 5 of 7 STATUS CODE DESCRIPTION FAIL 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10- B:C. 2.1n Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10-pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. GENERAL NOTES JEFF SIEBEL - 01/03/2025 @ 10:05 Location: Front and Back areas Original Comment: Properly mount 2 2A 10BC currently serviced Fire extinguishers 4" to5' above the floor in an accesible location . One in front area and one in back area. annual inspection $80 Printed on 01/03/2025 @ 10:32 Page 6 of 7 REINSPECTION DATE 01/30/2025 CONTACT SIGNATURE Jess Signed on: 01/03/2025 @ 09:43 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 01/03/2025 @ 09:43 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/03/2025 @ 10:32 Page 7 of 7