Loading...
HomeMy WebLinkAbout2134 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2025 02/28/2025 2025-00000240 $100.00 Customer #: 22859 FAIRFIELD INN AND SUITES 2134 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2134 LA PORTE RD - 1-15-24 [ Description FOR BILLING INQUIRY: (319)291-4323 INSPECTION 20,000 OCCUPANCY FEE Total Price ] $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22859 01/27/2025 02/28/2025 2025-00000240 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT FAIRFIELD INN & SUITES, 2134 LA PORTE RD, BLDG 2134 LA PORTE RD, WATERLOO /A 50702 Inspection Date: 01/15/2025 ( Inspection Type: Annual Inspection (1Yr) ( Inspection Number: 12175 ( Shift: N/A 1 Station: N/A j Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 34 I Violations: 22 I N/A Codes: 29 STATUS CODE DESCRIPTION FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: All new fire door hardware installed and additional hardware for guest rooms Original Comment: Obtain permit and inspections for all work planned or completed with fire doors. FAIL 102.4 - Application of building The design and construction of new structures shall comply with the code. International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Location: All new fire door hardware. Original Comment: Provide documentation to Waterloo Building Department for all fire door hardware when applying for permit: 1010.2.9.3 Installation. Where panic or fire exit hardware is installed, it shall comply with the following: 1. Panic hardware shall be listed in accordance with UL 305. 2. Fire exit hardware shall be listed in accordance with UL 10C and UL 305.3. The actuating portion of the releasing device shall extend not less than one-half of the door leaf width. 4. The maximum unlatching force shall not exceed 15 pounds (67 N). Printed on 01 /16/2025 @ 10:41 Page 1 of 9 STATUS CODE DESCRIPTION FAIL 1103.9 - Carbon monoxide Carbon monoxide alarms detection shall be installed in existing dwelling units alarmsdetection. and sleeping units Group 1-1, 1-2, 1-4 and R occupancies and in classrooms in Group E occupancies where those units include any of the conditions identified in Sections 915.1.2 through 915.1.6. The carbon monoxide alarms shall be installed in the locations specified in Section 915.2 and the installation shall be in accordance with Section 915.4. Exceptions: 1.Carbon monoxide alarms are permitted to be solely battery operated where the code that was in effect at the time of construction did not require carbon monoxide detectors to be provided. 2.Carbon monoxide alarms are permitted to be solely battery operated in dwelling units that are not served from a commercial power source. 3.A carbon monoxide detection system in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. FAIL Location: dryer room Original Comment: replace faulty CO detector. 1203.2.15 - Means of egress Emergency power shall be provided for means of egress illumination in illumination. accordance with Sections 1008.3 and 1104.5.1. Location: 3rd Floor inside housekeeping by ice machine. Original Comment: repair egress light. FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: By room 407 Original Comment: Repair exit sign. unable to test battery. button missing. Printed on 01/16/2025 @ 10:41 Page 2 of 9 STATUS CODE DESCRIPTION FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Exit sign by 308 Original Comment: repair exit sign FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not less than 90 minutes. Location: Outside of pool chemical storage room Original Comment: repair of exit light FAIL 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Pool deck Original Comment: repair 4/5 egress lights and 2 exit lights around pool FAIL 315.3.3 - Equipment rooms. Combustible material shall not be stored in boiler rooms, mechanical rooms, electrical equipment rooms or in fire command centers as specified in Section 508.1.5. Location: All electrical and mechanical rooms Original Comment: remove storage Printed on 01 /16/2025 @ 10:41 Page 3 of 9 STATUS CODE DESCRIPTION FAIL 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Location: Room 221 Original Comment: replace 2 missing eschutcheons FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70.2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: 3rd Floor Electrical Room Original Comment: remove all storage. (paint included) FAIL 603.4 - Working space and A working space of not Working space around electrical equipment shall be clearancesclearance. provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: 1st floor electrical room Original Comment: Remove storage Printed on 01 /16/2025 @ 10:41 Page 4 of 9 STATUS CODE DESCRIPTION FAIL 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Pool chemical room Original Comment: remove extension cord. Repair and utilize permanent outlet. FAIL 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Location: Guest and Commercial dryer vents Original Comment: provide documentation of dryer vent cleaning to the outside of the building for guest dryers and housekeeping commercial dryers. FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Room 433 Original Comment: replace missing smoke seal. Printed on 01/16/2025 @ 10:41 Page 5 of 9 STATUS CODE DESCRIPTION FAIL 704.1 - Maintaining Where required when the building was originally constructed, materials and protection. systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. FAI L FAI L Location: maintenance office fire door Original Comment: remove drop down foot. Fire door must remain closed unless held open by a fire alarm controlled magnet. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: 4th floor East stair fire door Original Comment: Fire door must completely self -close and latch 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: 3rd Floor East Fire Door Original Comment: Fire door must completely self -close and latch. Printed on 01/16/2025 @ 10:41 Page 6 of 9 STATUS CODE DESCRIPTION FAIL 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. FAI L Location: Storage Room by room 401 Original Comment: Fire door must completely self -close and latch. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Location: 1st floor womens restroom Original Comment: Fire door must completely self -close and latch. FAIL 903.3.3 - Obstructed Automatic sprinklers shall be installed with regard to obstructions that will delay locations. activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Location: Vitality room Original Comment: remove debris (string) from 2 fire sprinkler heads. Printed on 01 /16/2025 @ 10:41 Page 7 of 9 STATUS CODE DESCRIPTION FAIL 903.3.3 - Obstructed Automatic sprinklers shall be installed with regard to obstructions that will delay locations. activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. GENERAL NOTES JEFF SIEBEL - 01/16/2025 @ 10:27 REINSPECTION DATE 02/06/2025 Location: Room 102 Original Comment: replace fire sprinkler head . Head has paint. Annual Inspection $100 CONTACT SIGNATURE GM Cindy Huebner 2025 Signed on: 01/16/2025 @ 10:39 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 01/16/2025 @ 10:40 Printed on 01 /16/2025 @ 10:41 Page 8 of 9 QUESTIONS ABOUT TOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/16/2025 @ 10:41 Page 9 of 9