COMMERCIAL INSPECTION - 1931 SEARS ST - 1-16-24
FOR BILLING INQUIRY: (319)291-4323
[ Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
22165
01/27/2025
02/28/2025
2025-00000242
$80.00
Less Prepayment
Total Due
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
INSPECTION REPORT
TOKYO BAY, 1931 SEARS ST, BLDG 1931 SEARS ST, WATERLOO IA S0702
DETAILS
Inspection Date: 01/16/2025 I Inspection Type: Annual Inspection (1Yr) I Inspection Number: 13180 I Shift: N/A I Station: N/A I
Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 41 I Violations: 6 I N/A Codes: 27
STATUS CODE DESCRIPTION
FAIL 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously
maintained free from obstructions or impediments to full instant use in the case
of fire or other emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be used for any purpose
that interferes with a means of egress.
FAIL
Location: Stairs to loft for electrical and fire alarm room
Original Comment: REmove all storage from stairs and landing. Maintain a clear
path.
5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Location: Annual Fire Sprinkler
Original Comment: Provide documentation of annual fire sprinkler inspection
report with all discrepancies corrected. Currently 9 days past due. Contractor
must upload online to the compliance engine.
Printed on 01/17/2025 @ 15:54
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Location: 5 Year internal fire sprinkler inspection
Original Comment: Provide documentation of 5 year fire sprinkler inspection
report with all discrepancies corrected. Currently 247 days days past due.
Contractor must upload online to the compliance engine.
FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the
inspection, a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the
cleaning and when the cleaning took place. Such records shall be completed after
each inspection or cleaning and maintained.
Location: kitchen hood fire suppression inspection
Original Comment: Provide documentation of current semi-annual kitchen hood
fire suppression inspection report with all discrepancies corrected. Currently 165
days past due. Contractor must upload report online to the compliance engine.
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
Location: Annual fire extinguisher service
Original Comment: Provide annual fire extinguisher service.
Printed on 01/17/2025 @ 15:54
Page 2 of 3
STATUS CODE DESCRIPTION
FAIL Chapter 14 - Inspection, Fire alarm system tested at least annually by licensed contractor
testing, and maintenance
GENERAL NOTES
JEFF SIEBEL - 01/17/2025 @ 15:53
RE/NSPECTION DATE
02/07/2025
Location: Annual Fire Alarm Inspection
Original Comment: Provide current annual fire alarm inspection report with all
discrepancies corrected. Currently 106 days past due. Contractor must post
online to the compliance engine.
annua inspection $80