Loading...
HomeMy WebLinkAbout210 E TOWER PARK DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2025 02/28/2025 2025-00000236 $610.00 Customer #: 10758 SAM'S CLUB #6514 210 E TOWER PARK DR WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 210 E TOWER PARK DR - 1-21-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 100,000 OCCUPANCY FEE $600.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 10758 01/27/2025 02/28/2025 2025-00000236 $610.00 Less Prepayment Total Due —> City of Waterloo $0.00 $610.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT SAM'S CLUB, 210E TOWER PARK DR, BLDG 210 E TOWER PARK DR, WATERLOO M 50701 DETAILS Inspection Date: 01/21/2025 ( Inspection Type: Annual Inspection (1Yr) ; Inspection Number: 12174 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: JEREMIAH VANDYKE 910 VIOLATIONS AND COMPLIANCES Showing only violations and images for this inspection. Please reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 51 I Violations: 6 I N/A Codes: 16 STATUS CODE DESCRIPTION FAI L 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch - pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Location: Exit door by eco lab # 7 and case of shell oil Original Comment: Repair exit door. Exit door must unlatch and swing to full open with less than 15# force. Door would not open at all today. If replaced obtain permits and inspectcions. Printed on 01/22/2025 @ 09:58 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Location: Provide documentation of testing and repair of all emergency exit and egress lights with signature and date. FAIL 315.3.1 - Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2- foot (610 mm) ceiling clearance is not required for storage along walls in nonsprinklered areas of buildings. 2.The 18-inch (457 mm) ceiling clearance is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. FAIL FAI L Location: Aisle by fire door by ecolab #7 and Shell Oil Case Original Comment: Lower storage to allowable height. Currently almost touching plastic and would hold it up. 5.2.1 - Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection 603.2.2 - Unapproved conditionsOpen electrical terminations. Location: Annual Fire Sprinkler Inspection Deficiencies -dry heads need testing Original Comment: Provide current annual fire sprinkler sprinker inspection report with all deficiencies corrected. Current report lists 2 deficiencies. Contractor must upload corrections online to the compliance engine. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Cash room Original Comment: install missing outlet cover. Printed on 01/22/2025 @ 09:58 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 603.9.4 - Prohibited areas. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Location: Cash room and fire pump room Original Comment: remove portable electric heaters or provide documentation of listing of use for commerial use and proper clearances. GENERAL NOTES JEFF SIEBEL-01/22/2025 @ 08:20 annual inspection $600 JEFF SIEBEL - 01/22/2025 @ 09:53 Fire door drop test 5/13/24 JEFF SIEBEL - 01/22/2025 @ 09:53 Fire pump maintenance Elite 2/20/24 JEFF SIEBEL - 01/22/2025 @ 09:54 Fire Alarm inspection due 3/19/25 JEFF SIEBEL - 01/22/2025 @ 09:54 hood fire suppression due 3/30/25 REINSPECTION DATE 02/11/2025 CONTACT SIGNATURE Mike Ahmann - Fresh Manager Signed on: 01/22/2025 @ 09:55 Printed on 01/22/2025 @ 09:58 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 01/22/2025 @ 09:55 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/22/2025 @ 09:58 Page 4 of 4