Loading...
HomeMy WebLinkAbout218 DIVISION STlvt Customer #: 5729 CEDAR VALLEY FISH MARKET 218 DIVISION ST WATERLOO, IA 50703 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/27/2025 02/28/2025 2025-00000248 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 218 DIVISION ST - 12-19-24 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price ] $70.00 $10.00 CUSTOMER # BILLING DATE. DUE DATE INVOICE # CHARGES 5729 01/27/2025 02/28/2025 2025-00000248 $80.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT CEDAR VALLEY FISH MARKET, 218 DIVISION ST, BLDG 218 DIVISION ST, WATERLOO IA 50703 Inspection Date: 12/19/2024 I Inspection Type: Annual Inspe ion ( r) I Inspection Numbe\: 11502 j Shift: N/A I Station: N/A Unit: N/A I Lead Inspector: JEFF SIEBEL I Other Inspectors: /A Fee: $80.00 VIOLATIONS ANO COMPLIANCES Showing only violations and images for this inspection.lease reach out to the lead inspector for more details. Resolved Violations: 0 I Passed Codes: 30 I Violations: 4 I N/A Codes: 40 STATUS CODE FAI L FAI L 603.5 - Relocatable power taps and current taps.Multiplug adapters. 603.5 - Relocatable power taps and current taps.Multiplug adapters. DESCRIPTION Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Basement Original Comment: remove 2 freezers from power strip. They must plug directly into permanent wall outlet. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Front of store Original Comment: remove multiplug adapter from adding machine and price display. Power strip with manual reset may be utilized for light duty items such as computers, tv's etec but for nothing with a motor or anything that produces heating or cooling. Printed on 12/19/2024 @ 14:31 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 606.3.3.3 - Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. Location: kitchen hood fire suppression inspection report Original Comment: Provide current kitchen hood fire suppression inspection report with all discrepancies corrected. Currently 6 days past due. Contractor must upload online to the compliance engine. FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: upstairs and downstairs Original Comment: Provide annual service for fire extingiusers. GENERAL NOTES JEFF SIEBEL - 12/19/2024 @ 14:28 annual inspection $80 REINSPECTION DATE 01/23/2025 Printed on 12/19/2024 @ 14:31 Page2of3 CONTACT SIGNATURE Noel Morris Jr. or JR Signed on: 12/19/2024 @ 14:27 a-wrv: / INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/19/2024 @ 14:27 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 12/19/2024 @ 14:31 Page 3 of 3