COMMERCIAL INSPECTION - 1956 LAFAYETTE ST - 1-6-25
FOR BILLING INQUIRY: (319)291-4323
[ Description
REINSPECTION 1
Total Price j
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
3312
01/27/2025
02/28/2025
2025-00000246
$100.00
Less Prepayment
Total Due
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
�� 12
WATERLOO FIRE RESCUE
INSPECTION REPORT �
CORK'S GROCERY, 1956 LAFAYEITE ST, BLDG 1956 LAFAYETTE ST, WATERLOO /A S0703 UU
DETAILS
Inspection Date: 01/06/2025 Inspection Type: Annual Inspection (1Yr) ; Inspection Number: 11669-R1 I Shift: N/A I Station: N/A
Unit: N/A ( Lead Inspector: JEFF SIEBEL I Other Inspectors: N/A
VIOLATIONS AND COMPLIANCES
Showing only violations and images for this inspection. Please reach out to the lead inspector for more details.
Resolved Violations: 0 I Passed Codes: 0 I Violations: 4 I N/A Codes: 0
STATUS CODE DESCRIPTION
FAI L
FAI L
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
603.5 - Relocatable power
taps and current
taps.Multiplug adapters.
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Behind red bull and coke coolers and horizontal freezers
Original Comment: remove power strip. Freezers and coolers must plug directly
into permanent outlet. Install permanent outlet with permits and inspections.
Multiplug adapters, such as cube adapters, unfused plug strips or any other
device not complying with NFPA 70 shall be prohibited. The construction and use
of current taps and relocatable taps shall be in accordance with NFPA 70 and this
code.
Location: Behind pepsi/coke machines at end of aisle
Original Comment: remove multi -plug adapter . Coolers must plug directly into
permanent wall outlet. Install permanent outlet with proper permits and
inspections.
Printed on 01/06/2025 @ 14:36
Page 1 of 4
STATUS
FAIL
CODE
603.6 - Extension cords.
DESCRIPTION
Extension cords and flexible cordsshall not be a substitute for permanent wiring
and shall be listed and labeled in accordance with UL 817. Extension cords and
flexible cordsshall not be affixed to structures, extended through walls, ceilings
or floors, or under doors or floor coverings, nor shall such cords be subject to
environmental damage or physical impact. Extension cords shall be used only
with portable appliances. Extension cords marked for indoor use shall not be
used outdoors.
Location: between pepsi cooler and uupright freezer.
Original Comment: remove extension cord. Freezers and coolers must plug
directly into permanent outlet. Install permanent outlet with permits and
inspections.
Printed on 01/06/2025 @ 14:36
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in
accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to
reach an extinguisher shall not apply to the spectator seating portions of Group
A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance
shall be allowed to be once every 3 years for dry -chemical or halogenated agent
portable fire extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the following conditions are
met: 2.1.Electronic monitoring shall confirm that extinguishers are properly
positioned, properly charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a trouble signal.
2.3.The extinguishers shall be installed inside of a building or cabinet in a
noncorrosive environment. 2.4.Electronic monitoring devices and supervisory
circuits shall be tested every 3 years when extinguisher maintenance is
performed. 2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at
the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers
shall be permitted to be located at staff locations.
GENERAL NOTES
JEFF SIEBEL - 12/10/2024 @ 09:36
JEFF SIEBEL - 01/06/2025 @ 14:33
REINSPECTION DATE
01/30/2025
Location: Not Provided
Original Comment: provide annual service for fire extinguishers
annual inspection $80
Re -inspection fee $100
CONTACT SIGNATURE
Jasmine Jasmeen
Signed on: 01/06/2025 @ 14:33
P....e, L--c- L 5
Printed on 01/06/2025 @ 14:36
Page 3 of 4
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 01/06/2025 @ 14:33
QUESTIONS AIOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 01/06/2025 @ 14:36