Loading...
HomeMy WebLinkAbout2000 HAWTHORNE AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 01/02/2026 02/03/2026 2026-00000281 $80.00 Customer #: 20795 SAC'S NEIGHBORHOOD PUB 714 GRINDSTONE CIRCLE WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2000 HAWTHORNE AVE - 12-19-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 20795 BILLING DATE DUE DATE INVOICE # CHARGES 01/02/2026 02/03/2026 2026-00000281 $80.00 Less Prepayment Total Due — > City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report S.A.C's Neighborhood Bar - 2000 Hawthorne AVE, BLDG 2000 Hawthorne Ave, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 1211912025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA E. 3rd Street Inspection Number 15773 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 31 0 11 Q 34 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 01/02/2026 @ 08:07 $80 annual inspection fee BRAD BALDWIN - 01/02/2026 @ 08:13 Christmas lighting approved for temporary usage (90) days. BRAD BALDWIN - 01/02/2026 @ 08:41 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 01/23/2026 BRAD BALDWIN - 01/02/2026 @ 08:42 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 01/02/2026 @ 08:42 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Trish Jennings CHECKLISTS Date: BRAD BALDWIN 01/0212026 GENERATED ON 1/2/26. 8:44 AM 1 OF 5 Emergency Equipment Status Code Fail Fail 0 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Additional Codes Status Code Fail 0 Fail 0 603.1 - General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. 606.1- General. Commercial kitchen exhaust hoods shall comply with the requirements of the International Mechanical Code Description Location: Emergency egress lights Comments: Provide documentation of testing all emergency egress lighting in building including repairs made to maintain working properly., documentation shall include signature and date of responsible person. Location: Exit signs Comments: Provide documentation of testing all exit signs in building including repairs made to maintain working properly., documentation shall include signature and date of responsible person. Description Location: Kitchen Comments: Remove microwave from power strip and extension cord, appliance shall plug directly to wall outlet. Location: Kitchen Comments: Repair or replace exhaust to comply with Mechanical Code. Code questions shall be directed to Chief Mechanical Inspector, Brian Baker. GENERATED ON 1/2/26, 8:44 AM 2 OF 5 Electrical Safety Status Code Fail Fail Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Status Code Fail Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Description Location: Near main exit Comments: Remove power strip plugged to another power strip to lighted sign. Strip shall be plugged directly to wall outlet. Location: South patio Comments: Remove TV plugged to extension cord. Relocate TV to plug to wall outlet or would approve properly supported power strip with manual reset. Location: Bud Light sign above beer fridge Comments: Remove sign cord from above drop ceiling, cord shall not be concealed above ceiling. Description Location: Kitchen exhaust hood Comments: Exhaust system cleaning 10 days past due as of 112126. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. Location: Kitchen exhaust hood suppression Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 50 days past due with (1) deficiency/ GENERATED ON 1/2/26, 8:44 AM 3 OF 5 Fire Resistant Construction Maintenance Status Code Fail l�J 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Portable Fire Extingusihers Status Code Fail 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Description Location: Above bar Comments: Replace missing ceiling tiles Description Location: Kitchen Comments: Annually serviced fire extinguishers shall be properly mounted on wall bracket GENERATED ON 1/2/26, 8:44 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Date Paid Amount Paid invoice Number NIA Check Number NIA Transaction Number NIA GENERATED ON 1/2/26, 8:44 AM 5 OF 5