COMMERCIAL INSPECTION - 2000 HAWTHORNE AVE - 12-19-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
20795
BILLING DATE
DUE DATE
INVOICE #
CHARGES
01/02/2026
02/03/2026
2026-00000281
$80.00
Less Prepayment
Total Due — >
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
S.A.C's Neighborhood Bar - 2000 Hawthorne AVE, BLDG 2000 Hawthorne Ave,
Waterloo IA 50702
INSPECTION DETAILS
Inspection Date
1211912025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
NIA
E. 3rd Street
Inspection Number
15773
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
0 31 0 11 Q 34
Passed codes Failed codes NIA codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 01/02/2026 @ 08:07
$80 annual inspection fee
BRAD BALDWIN - 01/02/2026 @ 08:13
Christmas lighting approved for temporary usage (90) days.
BRAD BALDWIN - 01/02/2026 @ 08:41
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
01/23/2026
BRAD BALDWIN - 01/02/2026 @ 08:42
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 01/02/2026 @ 08:42
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Trish Jennings
CHECKLISTS
Date: BRAD BALDWIN 01/0212026
GENERATED ON 1/2/26. 8:44 AM
1 OF 5
Emergency Equipment
Status Code
Fail
Fail
0
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
Additional Codes
Status Code
Fail
0
Fail
0
603.1 - General.
Electrical equipment, wiring and systems required by this
code or the International Building Code shall be installed,
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10.
606.1- General.
Commercial kitchen exhaust hoods shall comply with the
requirements of the International Mechanical Code
Description
Location: Emergency egress lights
Comments: Provide documentation of testing all emergency egress
lighting in building including repairs made to maintain working
properly., documentation shall include signature and date of
responsible person.
Location: Exit signs
Comments: Provide documentation of testing all exit signs in
building including repairs made to maintain working properly.,
documentation shall include signature and date of responsible
person.
Description
Location: Kitchen
Comments: Remove microwave from power strip and extension cord,
appliance shall plug directly to wall outlet.
Location: Kitchen
Comments: Repair or replace exhaust to comply with Mechanical
Code. Code questions shall be directed to Chief Mechanical
Inspector, Brian Baker.
GENERATED ON 1/2/26, 8:44 AM
2 OF 5
Electrical Safety
Status Code
Fail
Fail
Fail
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Commercial Cooking Hood Suppression System
Status Code
Fail
Fail
606.3.3 - Cleaning.
Hoods, grease -removal devices, fans, ducts and other
appurtenances shall be cleaned at intervals as required by
Sections 606.3.3.1 through 606.3.3.3.
606.3.3.1 - Inspection.
Hoods, grease -removal devices, fans, ducts and other
appurtenances shall be inspected at intervals specified in
Table 606.3.3.1 or as approved by the fire code official.
Inspections shall be completed by qualified individuals.
Description
Location: Near main exit
Comments: Remove power strip plugged to another power strip to
lighted sign. Strip shall be plugged directly to wall outlet.
Location: South patio
Comments: Remove TV plugged to extension cord. Relocate TV to
plug to wall outlet or would approve properly supported power strip
with manual reset.
Location: Bud Light sign above beer fridge
Comments: Remove sign cord from above drop ceiling, cord shall not
be concealed above ceiling.
Description
Location: Kitchen exhaust hood
Comments: Exhaust system cleaning 10 days past due as of 112126.
Provide cleaning and report to be uploaded to Compliance Engine
with any deficiencies corrected.
Location: Kitchen exhaust hood suppression
Comments: Provide suppression system inspection report with any
deficiencies corrected. Contractor must upload report to Compliance
Engine. Currently 50 days past due with (1) deficiency/
GENERATED ON 1/2/26, 8:44 AM 3 OF 5
Fire Resistant Construction Maintenance
Status Code
Fail
l�J
704.1 - Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Portable Fire Extingusihers
Status Code
Fail
906.7 - Hangers and brackets.
Hand-held portable fire extinguishers, not housed in cabinets,
shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the
mounting surface in accordance with the manufacturer's
installation instructions.
Description
Location: Above bar
Comments: Replace missing ceiling tiles
Description
Location: Kitchen
Comments: Annually serviced fire extinguishers shall be properly
mounted on wall bracket