Loading...
HomeMy WebLinkAbout1139 DIXON DRWaterloo Fire Rescue Inspection Report Kel-Mar LC - 1139 Dixon DR, Waterloo IA 50701-4783 INSPECTION DETAILS trspection Date 12/02/2025 Lead Inspector BARRY STRATTON InspectictrType Rental Inspection f REINSPECTION Other inspectors N/A Suitt Kej Nr LC: Gkir)a9IIN ° 425 E. 3rd'Streei Inspection Number 17222-R5 NIA Station NIA Unit N/A SUMMARY OF INSPECTION 0 0 Passed codes NEXT STEPS 0 4 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 GENERAL NOTES BARRY STRATTON - 11104/2025 @ 10:24 304..12: Handrail on 1st floor back stairs bracket is loose. SIGNATURES Contact signature Inspector signature Danielle Morris CHECKLISTS Reinspection Date 01/06/2026 12/02/2025 BARRY STRATTON 12102/2025 GENERATED ON 12/2/25, 10'12 AM 1 OF 3 Reinspection Status Fail Fail Fail Fail 703.1- Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire -resistance -rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions, 907.2.11- Single- and multiple -station smoke alarms. Listed single- and multiple -station smoke alarms complying with UL 217 shall be installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) Description Location: Fire door closures not working. Doors held in open position. Location: Fire doors Location: Smoke detectors need to be in working condition. Location: Peeling paint on 2nd floor on wall separating apartments GENERATED ON 12/2/25, 10:12 AM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee NIA $250.00 Dale Paid Amount Paid Invoice Number Check Number NIA NIA Transaction Number NIA GENERATED ON 12/2/25, 10:12 AM 3 OF 3