Loading...
HomeMy WebLinkAbout1155 DIXON DRWaterloo Fire Rescue Inspection Report Kel-Mar LC - 1155 Dixon DR, Waterloo IA 50701-4785 INSPECTION DETAILS Ctnsp ctiwi bate 12102/2025 Lead Inspector BARRY STRATTON Cns;3eczion Type Rental Inspection ( REINSPECTION Other Inspectors NIA Shift NIA )a 0 425 E. 3rd Str Inspection Number 17218-R5 Station Unit NIA NIA SUMMARY OF INSPECTION 0 o Passed codes NEXT STEPS 0 2 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 SIGNATURES Contact signature Inspector signature Danielle Morris CHECKLISTS Reinspection Date 01/06/2026 12/0212025 BARRY STRATTON 12/0212025 GENERATED ON 12/2/25, 10:07 AM 1 OF 3 Reinspection Status Fail Fail Code 703.1 - Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire -resistance -rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and root or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall, 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Fire door closures not in working condition. Doors maintained in open position. Location: Fire doors GENERATED ON 12/2/25, 10:07 AM 2 OF 3 Statement of Fees FEE Invoice Date N/A Invoice Number N/A Inspection Fee $250.00 Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 12/2/25, 10:07 AM 3 OF 3 v _