COMMERCIAL INSPECTION - 1040 ALABAR - 11-10-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24870
12/09/2025
01/10/2026
2026-00000257
$80.00
Less Prepayment
Total Due —►
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Profile Aesthetics - 1040 Alabar AVE, BLDG 1040 Alabar Ave - STE 1012, Waterloo IA
50701
INSPECTION DETAILS
Inspection Date
11/10/2025
Lead Inspector
BRAD BALDWIN
inspection Type
Occupancy Final Inspection
Other Inspectors
NIA
425 E.3rd Street
Inspection Number
18926
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
0 2
Passed codes
NEXT STEPS
0 5 ®10
Failed codes N/A codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 11/19/2025 @ 08:17
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224
Reinspection Date
12/19/2025
BRAD BALDWIN - 11/19/2025 @ 08:19
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 11/19/2025 @ 08:19
$80 annual inspection fee
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Kaycee Jondal (2025) Date: BRAD BALDWIN 11/19/2025
CHECKLISTS
GENERATED ON 11/19/25, 8:20 AM 1 OF 4
Occupancy Final Inspection
status Code
Fail
lud
Fail
Fail
1004.9 - Posting of occupant load.
Every room or space that is an assembly occupancy shall
have the occupant load of the room or space posted in a
conspicuous place, near the main exit or exit access doorway
from the room or space, for the intended configurations.
Posted signs shall be of an approved legible permanent
design and shall be maintained by the owner or the owner's
authorized agent.
1013.1 - Where required.
Exits and exit access doors shall be marked by an approved
exit sign readily visible from any direction of egress travel.
The path of egress travel to exits and within exits shall be
marked by readily visible exit signs to clearly indicate the
direction of egress travel in cases where the exit or the path
of egress travel is not immediately visible to the occupants.
Intervening means of egress doors within exits shall be
marked by exit signs. Exit sign placement shall be such that
any point in an exit access corridor or exit passageway is
within 100 feet (30 480 mm) or the listed viewing distance of
the sign, whichever is less, from the nearest visible exit sign.
Exceptions: 1.Exit signs are not required in rooms or areas
that require only one exit or exit access. 2.Main exterior exit
doors or gates that are obviously and clearly identifiable as
exits need not have exit signs where approved by the fire
code official. 3.Exit signs are not required in occupancies in
Group U and individual sleeping units or dwelling units in
Group R-1, R-2 or R-3. 4.Exit signs are not required in
dayrooms, sleeping rooms or dormitories in occupancies in
Group 1-3. 5.In occupancies in Groups A-4 and A-5, exit signs
are not required on the seating side of vomitories or openings
into seating areas where exit signs are provided in the
concourse that are readily apparent from the vomitories.
Egress lighting is provided to identify each vomitory or
opening within the seating area in an emergency.
505.1 - Address identification.
New and existing buildings shall be provided with approved
address identification. The address identification shall be
legible and placed in a position that is visible from the street
or road fronting the property. Address identification
characters shall contrast with their background. Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke
width of 1/2 inch (12.7 mm). Where required by the fire code
official, address identification shall be provided in additional
approved locations to facilitate emergency response. Where
access is by means of a private road and the building cannot
be viewed from the public way, a monument, pole or other
sign or means shall be used to identify the structure. Address
identification shall be maintained.
Desrripfion
Comments: Inspector to supply occupant load to post near main exit.
Location: Rear exit
Comments: Rear exit obstructed by interior door. Second exit not
required per occupancy, options to be compliant as follows: (1)
would be approved to properly remove or cover exit sign and cap
electric in contained box with cover. (2) Remove interior door
obstructing view of exit and maintain exit sign.
Comments: Provide address number "1012" contrasting with building
to mark space for emergency services.
GENERATED ON 11/19/25, 8:20 AM
2 OF 4
906.1 - Where required.
Portable fire extinguishers shall be installed in all of the
following locations: 1.In new and existing Group A, B, E, F, H,
1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group
R-2 occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C. 2.In Group E
occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C. 3. In storage areas of Group
S occupancies where forklift, powered industrial truck or
powered cart operators are the primary occupants, fixed
extinguishers, as specified in NFPA 10, shall not be required
where in accordance with all of the following: 3.1. Use of
vehicle -mounted extinguishers shall be approved by the fire
code official. 3.2. Each vehicle shall be equipped with a 10-
pound, 40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use. 3.3. Not less than
two spare extinguishers of equal or greater rating shall be
available on -site to replace a discharged extinguisher. 3.4.
Vehicle operators shall be trained in the proper operation, use
and inspection of extinguishers. 3.5. Inspections of vehicle -
mounted extinguishers shall be performed daily. 2.Within 30
feet (9144 mm) distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group 1-
1; 1-2, Condition 1; and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed. 4.On each floor of structures under
construction, except Group R-3 occupancies, in accordance
with Section 3316.1. 5.Where required by the sections
indicated in Table 906.1. 6.Speciat-hazard areas, including but
not limited to laboratories, computer rooms and generator
rooms, where required by the fire code official. Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
Additional Codes
S[a[us Code
Fail
x
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
Comments: Provide (1) 2A:10B:C sized properly serviced fire
extinguisher installed and mounted on wall bracket in easily
accessible location. Maximum distance of travel to access fire
extinguisher in space (75 feet).
Description
Location: Change of occupancy
Comments: Permits obtained per change of occupancy shall pass
inspections to coincide with fire inspection.