COMMERCIAL INSPECTION - 1608 UNIVERSITY AVE - 12-5-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 2
$150.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24828
12/09/2025
01/10/2026
2026-00000249
$150.00
Less Prepayment
Total Due —�
City of Waterloo
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Green Leaf Tobacco and E-Cigs - 1608 University AVE, BLDG 1608 UNIVERSITY AVE
- STE B, Waterloo IA 50701
INSPECTION DETAILS
inspection Date
12/05/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr) l REINSPECTION
Other Inspectors
N/A
Shin
NIA
425 E. 3rd Street
Inspection Number
18017-R2
Station Unit
N/A NIA
SUMMARY OF INSPECTION
0 1 0 5 Q 6
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 11/07/2025 @ 14:44
$80 annual inspection fee
BRAD BALDWIN - 11/07/2025 @ 14:44
Fire extinguishers due annually serviced in September 2026
BRAD BALDWIN - 11/07/2025 @ 14:44
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
01/07/2026
BRAD BALDWIN - 11/07/2025 @ 14:44
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 11/07/2025 @ 14:44
$100 re -inspection fee, failure to make progress on correcting violations.
BRAD BALDWIN - 12/05/2025 @ 12:41
$150 re -inspection fee, failure to complete corrections as of 12/5/25.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
MO 2025 Date:
BRAD BALDWIN 12/05/2025
GENERATED ON 12/5/25, 12:52 PM 1 OF 6
CHECKLISTS
Additional Codes
SYalus Code
Fail
1032.2 - Reliability.
Required exit accesses, exits and exit discharges shall be
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other
emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
Description
Location: Back exit
Comments: Remove obstructions (boxes & trash can) from egress
path. Maintain clear path at all times. Exit not required per
occupancy, would be approved to properly remove exit signage.
GENERATED ON 12/5/25, 12:52 PM 2 OF 6
Reinspection
Status code
Fail
1032.2 - Reliability.
Required exit accesses, exits and exit discharges shall be
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other
emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
Description
Location: Back exit
Comments: Per occupancy, 2nd exit not required. Would be approved
to remove exit sign or properly cover. Removal requires electric
capped and contained in box with cover. Failure to cover or remove
sign requires removal of interior door obstructing view of exit and
removal of all obstructions to clear access of exit.
Additional comments: No progress made today - 12/5/25.
GENERATED ON 12/5/25, 12:52 PM 3 OF 6
Fail
Fail
l^J
315.3.3 - Equipment rooms.
Combustible material shall not be stored in boiler rooms,
mechanical rooms, electrical equipment rooms or in fire
command centers as specified in Section 508.1.5.
603.1 - General.
Electrical equipment, wiring and systems required by this
code or the International Building Code shall be installed,
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10.
Location: Mechanical room
Comments: Remove storage from mechanical room, maintain proper
clearance at all times.
Additional comments: Plywood noted leaning against furnace today
along with previously noted storage. ALL storage shall be removed
from room immediately.
Location: Near electric panel
Comments: Remove microwave from power strip, appliance shall be
plugged directly to wall outlet.
Additional comments: No progress made, explained hazard to staff
present today.
GENERATED ON 12/5/25, 12:52 PM 4 OF 6
Fail
o
Fail
o
603.1.1 - Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Location: Window lighting
Comments: Provide documentation of proper listing of light fixtures.
Noted "CE" listing as shown in picture not approved for use.
Location: Mechanical room
Comments: Remove tv cord from white extension cord. Would
approve TV plugged to properly mounted power strip with manual
reset plugged directly to wall outlet.
Additional comments: Storage blocking access to assess if corrected
or not today.