Loading...
HomeMy WebLinkAbout1915 BOURLANDINVOICE DATE DUE DATE, INVOICE # TOTAL DUE 12/09/2025 01/10/2026 2026-00000254 $80.00 Customer #: 23343 FUSION BAR 1915 BOURLAND WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1915 BOURLAND-11-17-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23343 12/09/2025 01/10/2026 2026-00000254 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Fusion Bar - 1915 Bourland AVE, BLDG 1915 Bourland Ave, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11/17/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other inspectors N/A 3(--i3 425 E. 3rd Street Inspection Number 15262 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 0 38 Passed codes NEXT STEPS 0 11 Failed codes 29 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 11/18/2025 @ 07:43 $80 annual inspection fee BRAD BALDWIN - 11/1812025 @ 07:45 Fire extinguishers self -purchased (11/5125). Receipt taped to bottom. Reinspection Date 12/10/2025 BRAD BALDWIN - 11/18/2025 @ 07:55 Corrected during 11/17125 inspection: (1) Removed light cord running through doorway from kitchen to hallway. (2) Removed extension cord behind kitchen fridge. BRAD BALDWIN - 11118/2025 @ 08:11 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224 BRAD BALDWIN - 11/18/2025 @ 08:11 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 11/18/2025 @ 08:11 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100. then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 11/18/25, 8:33 AM 1 OF 8 Hassan Puric CHECKLISTS Emergency Equipment States Code Fail Fail Date: BRAD BALDWIN 11/1812025 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Storage room Comments: Repair or replace egress lights that failed to illuminate during test. Location: East exit Comments: Repair or replace exit sign & lights that failed to illuminate during test. GENERATED ON 11/18/25, 8:33 AM 2 OF 8 Electrical Safety Status Code Fail 603.4 - Working space and clearancesciearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Storage room Comments: Clear obstructions to clear path of access to electric panels. Maintain path at all times. GENERATED ON 11/18/25, 8:33 AM 3 OF 8 Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Fail 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Seating area Comments: Properly mount power strip to wall or support on shelf avoid hanging by wires. Location: Storage room near electric panels Comments: Properly mount power strip to wall or support on shelf avoid hanging by wires. GENERATED ON 11/18/25, 8:33 AM 4 OF 8 Fail C. Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Seating area Comments: Remove white extension cord and lighting cord from above drop ceiling. Flexible cords not allowed in concealed areas. Location: Jukebox Comments: Remove jukebox from multi -plug extension cord. May replace with power strip with manual reset plugged directly to wall outlet or licensed electrical contractor may add outlet with permit and inspection. GENERATED ON 11/18/25, 8:33 AM 5 OF 8 Fail Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.8 - Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days. Temporary wiring methods shall meet the applicable provisions of NFPA 70. Exception: Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling, repair or demolition of buildings, structures, equipment or similar activities. Location: Above bar beverage fridge Comments: Remove orange extension cord from permanent usage. Allowed for temporary use only for light duty electric. Location: Above pool table Comments: Remove white cord and also Budweiser cord from above drop ceiling. Flexible cords not allowed in concealed areas. Location: Exterior Christmas lighting Comments: Lighting allowed for 90 days, shall be removed by 2/15/25. GENERATED ON 11/18/25, 8:33 AM 6 OF 8 Additional Codes Status Code Fail 807.2 - Combustible decorative materials. In Groups A, B, E, I, M and R-1 and in dormitories in Group R- 2, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached. Fixed or movable walls and partitions, paneling, wall pads and crash pads applied structurally or for decoration, acoustical correction, surface insulation or other purposes shall be considered to be interior finish, shall comply with Section 803 and shall not be considered decorative materials or furnishings. Exceptions: 1.In auditoriums in Group A, the permissible amount of curtains, draperies, fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, and where the material is installed in accordance with Section 803.15 of the International Building Code. 2.In Group R-2 dormitories, within sleeping units and dwelling units, the permissible amount of curtains, draperies, fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1. 3.In Group B and M occupancies, the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited. 4.The 10-percent limit shall not apply to curtains, draperies, fabric hangings and similar combustible decorative materials used as window coverings. Description Location: Kitchen Comments: Window coverings shall be removed or replaced with proper fire -retardant material. GENERATED ON 11/18/25, 8:33 AM 7 OF 8 Statement of Fees FEE invoice Date Inspection Fee NIA $80.00 Date Paid Amount Paid Invoice Number NIA Check Number NIA Transaction Number N/A GENERATED ON 11/18/25, 8:33 AM 8 OF 8