Loading...
HomeMy WebLinkAbout325 CMMERCIALINVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/09/2025 01/10/2026 2026-00000248 $100.00 Customer #: 22975 SINGLE SPEED 325 COMMERCIAL ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 325 COMMERCIAL - 11-21-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 22975 12/09/2025 01/10/2026 2026-00000248 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Single Speed Brewing - 325 Commercial ST, BLDG 325 Commercial St, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11/21/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Qiac1.-7s Other Inspectors N/A 425 E. 3rd Street Inspection Number 15713 Shit, Station Unit N/A N/A N/A SUMMARY OF INSPECTION 0 56 Passed codes NEXT STEPS 11 Failed codes 10 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 11/2412025 @ 13:19 $100 annual inspection fee BRAD BALDWIN - 11/24/2025 @ 13:35 Kitchen exhaust hood suppression system due for service 1-9-26 BRAD BALDWIN - 11/24/2025 @ 13:39 Fire extinguishers due annually serviced in May 2026 Reinspection Date 12/18/2025 BRAD BALDWIN - 11124/2025 @ 13:47 Corrected during 11/21/25 inspection: (1) Removed cart blocking kitchen hood suppression pull station and fire extinguisher. (2) Removed item resting on sprinkler pipe in kitchen. BRAD BALDWIN - 11/24/2025 @ 13:54 Contractor permits obtained for current remodel shall be inspected and passed at time of completion of work. BRAD BALDWIN - 1112412025 @ 13:54 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 11/24/2025 @ 13:54 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 11/24/2025 @ 13:54 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 11/24/2025 @ 13:57 GENERATED ON 11/24/25, 2:00 PM 1 OF 9 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Derrick Akers Date: BRAD BALDWIN 1112412025 CHECKLISTS Means of Egress cod, Description Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Code Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Boiler room Comments: Remove obstructions to exit path (floor scrubber, boxes, chair). Maintain clear path to exit at all times. Description Comments: Provide report of testing of all emergency egress lighting including repairs made with signature and date. Email report to inspector. Comments: Provide report of testing of all exit signs including repairs made with signature and date. Email report to inspector. GENERATED ON 11/24/25, 2:00 PM 2 OF 9 Additional Codes Coda Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Description Location: Walk-in beer cooler Comments: Secure compressed beer gas tanks with chain to avoid tip over. GENERATED ON 11/24/25, 2:00 PM 3 OF 9 Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Fail 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Location: Brewery lab Comments: Secure compressed gas cylinder with chain to avoid tip over. Location: Bar mini fridges (2) Comments: Fridges plugged to power strips shall be plugged directly to wall outlets. Relocate fridges or licensed electrical contractor may add outlet with obtaining permit and inspection. GENERATED ON 11/24/25, 2:00 PM 4 OF 9 Electrical Safety Status cod:* Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). sciption Location: Water Tank Room (Panel LVIC) Comments: Remove pallets and all storage within 36" in front of panels. Maintain clearances at all times. GENERATED ON 11/24/25, 2:00 PM 5 OF 9 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Outside office Comments: Remove combustibles (plastic) and all storage from within 36" of electric panels. Maintain clearance at all times. GENERATED ON 11/24/25, 2:00 PM 6 OF 9 Fail Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Location: Bar Comments: Remove cube style multi -plug adapter. May replace with properly mounted power strip with manual reset for Tight duty electric only. Location: Bar, near mini fridges Comments: Power strip shall be properly supported or mounted on wall to avoid hanging by wires GENERATED ON 11/24/25, 2:00 PM 7 OF 9 Commercial Cooking Hood Suppression System Sttu_ Cai_ Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Description Location: Kitchen exhaust hood Comments: Exhaust system cleaning past due as of 11/21125. Provide cleaning and report to be uploaded to Compliance Engine with any deficiencies corrected. GENERATED ON 11/24/25, 2:00 PM 8 OF 9 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 11/24/25, 2:00 PM 9 OF 9