Loading...
HomeMy WebLinkAbout308 WASHINGTON STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/09/2025 01/10/2026 2026-00000246 $80.00 Customer #: 21386 SNOWDEN HOUSE 306 WASHINGTON WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City ClerWAccounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 306 WASHINGTON ST - 11-24-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 21386 12/09/2025 01/10/2026 2026-00000246 $80.00 Less Prepayment Total Due —� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Snowden House - 306 Washington ST, BLDG 306 Washington St, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11/24/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 15873 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 029 08 ®37 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 11125/2025 @ 08:53 $80 annual inspection fee BRAD BALDWIN - 11125/2025 @ 09:34 Corrected during 11/24/25 inspection: Removed power strip from extension cord on stage 2nd floor. BRAD BALDWIN - 11125/2025 @ 13:47 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 12118/2025 BRAD BALDWIN - 11/25/2025 @ 13:47 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 11125/2025 @ 13:47 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature Alan Sweeney CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 11/25/2025 GENERATED ON 11/25/25, 1:50 PM 1 OF 6 Means of Egress Status Code Fail 1104.16.5.1 - Examination. Fire escape stairways and balconies shall be examined for structural adequacy and safety in accordance with Section 1104.16.5 by a registered design professional or others acceptable to the fire code official every 5 years, or as required by the fire code official. An inspection report shall be submitted to the fire code official after such examination. Emergency Equipment status Code Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. General Housekeeping Status Code Fail 305.1- Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Additional Codes Status Code Fail 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Description Location: Fire escape Comments: Provide 5 year inspection report by licensed contractor. Email report to inspector. Description Comments: Provide report with any deficiencies corrected of all emergency egress lighting in building with date and signature of person testing. Email report to inspector. Comments: Provide report with any deficiencies corrected of all exit signs in building with date and signature of person testing. Email report to inspector. Description Location: Basement Comments: Remove combustible material from within 36" from gas fired appliances. Maintain clearance at all times. Description Location: Basement Comments: Remove dehumidifier from extension cord, shall be plugged directly to wall outlet. Extension cord for temporary use only. GENERATED ON 11/25/25, 1:50 PM 2 OF 6 Electrical Safety £ifiE;;S Code Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: West exterior of building behind A/C's Comments: Repair box to avoid hanging by wires. GENERATED ON 11/25/25, 1:50 PM 3 OF 6 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: 2nd floor stage Comments: Remove storage within 36 " in front of electric panel. Maintain clearance at all times. GENERATED ON 11/25/25, 1:50 PM 4 OF 6 Portable Fire Extingusihers Scat€.= Cod;: Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.1.-oss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Comments: Provide annual service to all fire extinguishers, currently past due as of October 2025 GENERATED ON 11/25/25, 1:50 PM 5 OF 6 r ANN Flo FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 112525, 1:50 PM 6 OF 6