Loading...
HomeMy WebLinkAbout228 E 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/09/2025 01/10/2026 2026-00000245 $80.00 Customer #: 14048 SCREAMING EAGLE 228 E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 228 E 4TH - 11-25-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 14048 12/09/2025 01/10/2026 2026-00000245 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Screaming Eagle Bar & Grill - 228 E 4th ST, BLDG 228 E 4th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 11/25/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) ) 9 0 y? Other inspectors NIA 425 E. 3rd Street Inspection Number 19099 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 57 Passed codes NEXT STEPS 0 8 Failed codes Q 9 N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 11125/2025 @ 14:40 $80 annual inspection fee BRAD BALDWIN - 11/26/2025 @ 09:17 Christmas lights approved for temporary usage (90 days). Lights may remain in use till 2123/25. BRAD BALDWIN - 11126/2025 @ 09:17 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 12/19/2025 BRAD BALDWIN - 11/26/2025 @ 09:18 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 11/26/2025 @ 09:18 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 11/26/2025 @ 09:18 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 11/26/25, 9:21 AM 1 OF 4 Jeremy Jones CHECKLISTS Emergency Equipment S,a,ds Code Date: BRAD BALDWIN 11/26/2025 Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Fire Sprinkler System Status Code Fail 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Additional Codes St tUS Fail Description Location: Basement above bar Comments: Repair or replace emergency egress lights that failed to illuminate during test. Location: Front exit Comments: Repair or replace exit sign and lights that failed to illuminate during test. Description Location: Women's bathroom Comments: Remove dust build up on sprinkler heads Coda Description 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Location: Basement electric panel room Comments: Secure all compressed gas cylinders with chain to avoid tip over. GENERATED ON 11/26/25, 9:21 AM 2 OF 4 Commercial Cooking Hood Suppression System Stat s Cod Fail Fail 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSUIKECA C10. Fire Resistant Construction Maintenance Status Code Fail 705.2.6 - Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Portable Fire Extingusihers Status. Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Kitchen exhaust hood suppression Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 313 days past due as of 11/25/25. Location: Kitchen Comments: Clean grease accumulation on hood exhaust filters and behind conveyor oven. Description Location: Kitchen fire door Comments: Provide fire drop door test by licensed contractor, email report to inspector. Description Comments: Provide annual service to all fire extinguishers in building. Service past due as of January 2025. GENERATED ON 11/26/25, 9:21 AM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 112625, 9:21 AM 4 OF 4