Loading...
HomeMy WebLinkAbout503 SOUTH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/09/2025 01/10/2026 2026-00000247 $100.00 Customer #: 12081 GROUT MUSEUM 503 SOUTH ST WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 503 SOUTH ST - 11-24-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DIJE DATE INVOICE # CHARGES 12081 12/09/2025 01/10/2026 2026-00000247 $100.00 Less Prepayment Total Due --> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Grout Museum - 503 South ST, BLDG 503 South St, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11►24/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 15874 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 51 Passed codes NEXT STEPS ® 10 Failed codes 15 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 1112512025 @ 08:12 $100 annual inspection fee BRAD BALDWIN - 11/25/2025 @ 08:48 • Commercial Fire Inspector — brad.baldwin@waterloo-ia.org — Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 12/18/2025 BRAD BALDWIN - 11125/2025 @ 08:48 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 11/25/2025 @ 08:49 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday — Friday, 9:00 a.m. — 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 11125/2025 © 08:50 Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection zip Alan Sweeney Date: BRAD BALDWIN 11/25/2025 CHECKLISTS GENERATED ON 11/25/25, 8:52 AM 1 OF 6 Emergency Equipment Status Crude Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Fire Alarm System S. _..,.. Cct: Fail Chapter 14 - Inspection, testing, and maintenance Fire alarm system tested at least annually by licensed contractor Fire Sprinkler System ..,�...._ Code Fail 4.9 - Support of nonsprinkler system components Sprinkler system components shall not be used to support non -sprinkler system components unless expressly permitted by NFPA 13. Description Comments: Provide report with any deficiencies corrected of all emergency egress lighting in building with date and signature of person testing. Email report to inspector. Comments: Provide report with any deficiencies corrected of all exit signs in building with date and signature of person testing. Email report to inspector. Description Comments: Provide inspection report of fire alarm with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 21 days past due as of 11/25/25. Description Location: Furniture storage Comments: Remove and relocate wire taped to sprinkler pipe. GENERATED ON 11/25/25, 8:52 AM 2 OF 6 Electrical Safety Status Code Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Park lot median Comments: Repair loose conduit to box exposing wires. Location: Parking lot median Comments: Repair damaged box and conduit exposing wires. GENERATED ON 11/25/25, 8:52 AM 3 OF 6 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Marketing storage Comments: Remove obstructions and all storage within 36" in front of electric panel. Maintain clearance at all times. Location: Lower level "Mess Hall" storage Comments: Remove obstructions and all storage within 36" in front of electric panel. Maintain clearance at all times. GENERATED ON 11/25/25, 8:52 AM 4 OF 6 Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Portable Fire Extingusihers Status Cod:-3 Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Curator office Comments: Remove power strip plugged to another power strip. Description Comments: Provide annual service to all fire extinguishers, currently past due as of October 2025 GENERATED ON 11/25/25, 8:52 AM 5 OF 6 Na Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 11/25/25, 8:52 AM 6 OF 6