Loading...
HomeMy WebLinkAbout218 DIVISION STINVOICE DATE DUE DATE 12/09/2025 Customer #: 5729 CEDAR VALLEY FISH MARKET 218 DIVISION ST WATERLOO, IA 50703 01/10/2026 INVOICE # 2026-00000242 TOTAL DUE $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 218 DIVISION ST - 12-3-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 1 HH OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 5729 BILLING DATE 12/09/2025 DUE DATE 01/10/2026 INVOICE # 2026-00000242 CHARGES $80.00 City of Waterloo Less Prepayment Total Due —0 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 1 572.g Waterloo Fire Rescue Inspection Report Cedar Valley Fish Market - 218 Division ST, BLDG 218 Division St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 12/03/2025 Lead Inspector BRAD BALDWIN Annual Inspection (1Yr) Other Inspectors N/A Shift Station NIA NIA 425 E. 3rd Street Inspection Number 16054 Unit N/A SUMMARY OF INSPECTION 043 7 Passed codes NEXT STEPS ®24 Failed codes N/A codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN-12104/2025 @ 07:04 • $80 annual inspection fee BRAD BALDWIN - 12/0412025 @ 07:04 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 12/04/2025 @ 07:04 Reinspection Date 12/29/2025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 12104/2025 @ 07:04 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.rn. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 12/04/2025 @ 07:05 • Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date. Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature Noel Morris Jr. or JR CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 12104/2025 GENERATED ON 12/4/25, 8:27 AM 1 OF 7 Means of Egress Status Code Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Staucs Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Description Location: Basement egress Comments: Clear obstructions in path of egress. Maintain 36" path of egress at all times for emergency service people and staff access to exits to evacuate area. Des ptio Location: Basement Comments: Exit signs (2) in basement not required per occupancy, may be removed by properly capping wires and containing in box with cover, or if exit signs remain in place they shall be repaired or replaced to be illuminated. GENERATED ON 12/4/25, 8:27 AM 2 OF 7 Fire Service Features Status Cods Fail 506.1- Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire -fighting purposes, the fire code official is authorized to require a key box to be installed in an approved location. The key box shall be of an approved type listed in accordance with UL 1037, and shall contain keys to gain necessary access as required by the fire code official. Description Location: Basement Comments: All ceiling tiles missing shall be replaced. GENERATED ON 12/4/25, 8:27 AM 3 OF 7 Additional Codes Status Code Fail 603.1 - General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. Description Location: Basement freezer Comments: Remove freezer from power strip, appliance shall be plugged to wall outlet. GENERATED ON 12/4/25, 8:27 AM 4 OF 7 Electrical Safety Status Cods Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.9.4 - Prohibited areas. Portable, electric space heaters shall not be operated within 3 feet (914 mm) of any combustible materials. Portable, electric space heaters shall be operated only in locations for which they are listed. Description Location: Above drop ceiling in dining area Comments: Remove extension cords to security cameras concealed above drop ceiling. If adding new outlets, licensed electrical contractor shall obtain permit and inspection. Location: Behind counter Comments: JR stated space heater is being removed from building. If heater is in use, provide documentation of commercial listing. GENERATED ON 12/4/25, 8:27 AM 5 OF 7 Portable Fire Extingusihers S ztjs Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Basement fire extinguisher Comments: Spare extinguisher shall be annually serviced and properly mounted on wall bracket or may be removed from building. GENERATED ON 12/4/25, 8:27 AM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 12/4/25, 8:27 AM 7 OF 7