COMMERCIAL INSPECTION - 218 DIVISION ST - 12-3-25
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 1 HH
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
5729
BILLING DATE
12/09/2025
DUE DATE
01/10/2026
INVOICE #
2026-00000242
CHARGES
$80.00
City of Waterloo
Less Prepayment
Total Due —0
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
1
572.g
Waterloo Fire Rescue
Inspection Report
Cedar Valley Fish Market - 218 Division ST, BLDG 218 Division St, Waterloo IA 50703
INSPECTION DETAILS
Inspection Date
12/03/2025
Lead Inspector
BRAD BALDWIN
Annual Inspection (1Yr)
Other Inspectors
N/A
Shift Station
NIA NIA
425 E. 3rd Street
Inspection Number
16054
Unit
N/A
SUMMARY OF INSPECTION
043 7
Passed codes
NEXT STEPS
®24
Failed codes N/A codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN-12104/2025 @ 07:04
• $80 annual inspection fee
BRAD BALDWIN - 12/0412025 @ 07:04
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 12/04/2025 @ 07:04
Reinspection Date
12/29/2025
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 12104/2025 @ 07:04
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.rn. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 12/04/2025 @ 07:05
• Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled
inspection date. Failure to request time or change of date will result in failed inspection.
SIGNATURES
Contact signature Inspector signature
Noel Morris Jr. or JR
CHECKLISTS
No signature
Report completed post inspection
Date: BRAD BALDWIN 12104/2025
GENERATED ON 12/4/25, 8:27 AM 1 OF 7
Means of Egress
Status Code
Fail
1032.2 - Reliability.
Required exit accesses, exits and exit discharges shall be
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other
emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
Emergency Equipment
Staucs Code
Fail
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
Description
Location: Basement egress
Comments: Clear obstructions in path of egress. Maintain 36" path of
egress at all times for emergency service people and staff access to
exits to evacuate area.
Des
ptio
Location: Basement
Comments: Exit signs (2) in basement not required per occupancy,
may be removed by properly capping wires and containing in box
with cover, or if exit signs remain in place they shall be repaired or
replaced to be illuminated.
GENERATED ON 12/4/25, 8:27 AM 2 OF 7
Fire Service Features
Status Cods
Fail
506.1- Where required.
Where access to or within a structure or an area is restricted
because of secured openings or where immediate access is
necessary for life-saving or fire -fighting purposes, the fire
code official is authorized to require a key box to be installed
in an approved location. The key box shall be of an approved
type listed in accordance with UL 1037, and shall contain
keys to gain necessary access as required by the fire code
official.
Description
Location: Basement
Comments: All ceiling tiles missing shall be replaced.
GENERATED ON 12/4/25, 8:27 AM 3 OF 7
Additional Codes
Status Code
Fail
603.1 - General.
Electrical equipment, wiring and systems required by this
code or the International Building Code shall be installed,
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10.
Description
Location: Basement freezer
Comments: Remove freezer from power strip, appliance shall be
plugged to wall outlet.
GENERATED ON 12/4/25, 8:27 AM 4 OF 7
Electrical Safety
Status Cods
Fail
Fail
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
603.9.4 - Prohibited areas.
Portable, electric space heaters shall not be operated within 3
feet (914 mm) of any combustible materials. Portable, electric
space heaters shall be operated only in locations for which
they are listed.
Description
Location: Above drop ceiling in dining area
Comments: Remove extension cords to security cameras concealed
above drop ceiling. If adding new outlets, licensed electrical
contractor shall obtain permit and inspection.
Location: Behind counter
Comments: JR stated space heater is being removed from building. If
heater is in use, provide documentation of commercial listing.
GENERATED ON 12/4/25, 8:27 AM
5 OF 7
Portable Fire Extingusihers
S ztjs Code
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Description
Location: Basement fire extinguisher
Comments: Spare extinguisher shall be annually serviced and
properly mounted on wall bracket or may be removed from building.