HomeMy WebLinkAbout630 SYCAMORE STE 2INVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
11/14/2025
12/19/2025
2026-00000029
$250.00
Customer #: 24799
JH REAL ESTATE GROUP
153 PARKWOOD
FORT DODGE, IA 50501
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION-630 SYCAMORE STE #2-11/12/2025
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24799
11/14/2025
12/19/2025
2026-00000029
$250.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report W
0-Qc
628 Sycamore St - 630 Sycamore ST, BLDG 630 Sycamore St - STE 2, Waterloo IA
Soso
50703 /' 1 � I
a�7R9 B4-- oQLtt @Lfj flC
INSPECTION DETAILS
Inspection Date
1111212025
Lead inspector
BARRY STRATTON
Inspection Type
Rental Inspection REINSPECTION
Other lnspectors
NIA
Shift
NIA
Station
NIA
Inspection Number
17255-R4
Unit
N/A
SUMMARY OF INSPECTION
0
Passed codes
NEXT STEPS
Q 7
Failed codes
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
Reinspection Date
12/16/2025
BARRY STRATTON - 11/12/2025 @ 09:48
304.15Exterior doors, door assemblies, operator systems, and hardware shall be maintained in good condition. Locks on means of egress shall be in
accordance with Section 702.3 --- Front door hardware malfunctioning and window and trim holding window in is broken.
BARRY STRATTON - 11112/2025 @ 09:50
Bricks falling off building. Structural failure on bond beams and lentils. Mortar crumbling and building needs attention to shore up brick failure.
SIGNATURES
Contact signature Inspector signature
JH Real Estate Group LLC
CHECKLISTS
11/12/2025 BARRY STRATTON 11112/2025
GENERATED ON 11/12/25, 9:53 AM 1 OF 4
Reinspection
Code
Fail 603.2 - Abatement of unsafe conditions and electrical
Fail
Fail
Fail
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
703.1 - Maintaining protection.
Materials and firestop systems used to protect membrane and
through penetrations in fire -resistance -rated construction and
construction installed to resist the passage of smoke shall be
maintained. The materials and firestop systems shall be
securely attached to or bonded to the construction being
penetrated with no openings visible through or into the cavity
of the construction. Where the system design number is
known, the system shall be inspected to the listing criteria
and manufacturer's installation instructions.
705.2 - Inspection and maintenance.
Opening protectives in fire -resistance -rated assemblies shall
be inspected and maintained in accordance with NFPA 80.
Opening protectives in smoke barriers shall be inspected and
maintained in accordance with NFPA 80 and NFPA 105.
Openings in smoke partitions shall be inspected and
maintained in accordance with NFPA 105. Fire doors and
smoke and draft control doors shall not be blocked,
obstructed, or otherwise made inoperable. Fusible links shall
be replaced promptly whenever fused or damaged. Opening
protectives and smoke and draft control doors shall not be
modified.
901.6 - Inspection, testing and maintenance.
Fire detection and alarm systems, emergency alarm systems,
gas detection systems, fire -extinguishing systems,
mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained
in an operative condition at all times, and shall be replaced or
repaired where defective. Nonrequired fire protection and life
safety systems and equipment shall be inspected, tested and
maintained or removed in accordance with Section 901.8 .
Location: Fire separation between floors from unit 2 laundry area.
Location: Laundry room fire separation between apartment and
commercial space.
Location: Floor system between residential and commercial space.
Location: Egress light at top of stairs broken. Need Fire Extinguisher
in units. Fire separation between floors of commercial business and
apartments needs to meet fire code. Hole between floors.
GENERATED ON 11/12/25, 9:53 AM 2 OF 4
Fail
Fail
Fail
906.1- Where required.
Portable fire extinguishers shall be installed in all of the
following locations: 1.In new and existing Group A, B, E, F, H,
1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group
R-2 occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C. 2.In Group E
occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C. 3. In storage areas of Group
S occupancies where forklift, powered industrial truck or
powered cart operators are the primary occupants, fixed
extinguishers, as specified in NFPA 10, shall not be required
where in accordance with all of the following: 3.1. Use of
vehicle -mounted extinguishers shall be approved by the fire
code official. 3.2. Each vehicle shall be equipped with a 10-
pound, 40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use. 3.3. Not less than
two spare extinguishers of equal or greater rating shall be
available on -site to replace a discharged extinguisher. 3.4.
Vehicle operators shall be trained in the proper operation, use
and inspection of extinguishers. 3.5. Inspections of vehicle -
mounted extinguishers shall be performed daily. 2.Within 30
feet (9144 mm) distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1; 1-2, Condition 1; and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed. 4.On each floor of structures under
construction, except Group R-3 occupancies, in accordance
with Section 3316.1. 5.Where required by the sections
indicated in Table 906.1. 6.Special-hazard areas, including but
not limited to laboratories, computer rooms and generator
rooms, where required by the fire code official. Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
907.2.11- Single- and multiple -station smoke alarms.
Listed single- and multiple -station smoke alarms complying
with UL 217 shall be installed in accordance with Sections
907.2.11.1 through 907.2.11.7 and NFPA 72.
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Fire Extinguisher needed in apartments.
Location: Maintain smoke detectors in working condition. Smoke
detector will need installed in hallway outside bedrooms
Location: Bathtub not draining.
GENERATED ON 11/12/25, 9:53 AM
3 OF 4
Statement of Fees
FEE
Invoice Date Inspection Fee
N/A $250.00
Invoice Number
N/A
Date Paid Amount Paid
Check Number Transaction Number
N/A N/A
GENERATED ON 11/12/25, 9:53 AM
4 OF 4