Loading...
HomeMy WebLinkAbout1200 MEADOW LANE STE F.rrnr►..-.. INVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/14/2025 12/19/2025 2026-00000028 $50.00 Customer #: 23270 30 SOMETHING REAL ESTATE LLC 3522 AUGUSTA CIR Waterloo, IA 50704 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION-1200 MEADOW LANE STE F-11/12/2025 FOR BILLING INQUIRY: (319)29I-4323 Description Total Price REINSPECTION FEE 1ST $50.00 CUSTOMER # BILLING DATE DIJE DATE INVOICE # CHARGES 23270 11/14/2025 12/19/2025 2026-00000028 $50.00 Less Prepayment Total Due — > City of Waterloo $0.00 $50.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. a30a Waterloo Fire Rescue Inspection Report Apt F - 1200 Meadow LN, BLDG 1200 Meadow Ln - STE F, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11/1212025 Lead Inspector BARRY STRATTON Inspection Type Rental Inspection REINSPECTION ) Other Inspectors N/A OQSZSttle P.a. Pc < 425 E. 3rd Street O J k 5o1 Inspection Number 17092-R5 Shift Station Unit N/A N/A N/A SUMMARY OF INSPECTION O 0 Passed codes NEXT STEPS 0 7 Failed codes Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 GENERAL NOTES BARRY STRATTON - 11/12/2025 @ 09:55 Reinspection Date 12/16/2025 505.4: Water heating facilities shall be properly installed, maintained, and capable of preforming its intended function. Water not installed to code. Gas pipe needs to be black pipe and not appliance pipe. BARRY STRATTON - 1111212025 @ 09:56 1200 Meadow Ln Apt F SIGNATURES Contact signature Inspector signature MGT Property Management CHECKLISTS 11112/2025 BARRY STRATTON 11/12/2025 GENERATED ON 11/12/25. 9:58 AM 1 OF 4 Reinspection Status Fall Fail Fail Code 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 705.2 - Inspection and maintenance. Opening protectives in fire -resistance -rated assemblies shall be inspected and maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. 906.1 - Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.in new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.ln Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B;C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.1n areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Location: Light in kitchen of Apt F is has damage from water. Water is leaking into apartment. Location: Fire doors are being held in the open position. Location: Fire extinguishers will need updated/replaced at building. Extinguishers last checked in 2020. GENERATED ON 11/12/25, 9:58 AM 2 OF 4 Fail Fail R2 - Unsafe Equipment Was the presence of unsafe equipment noted during the inspection? Equipment may include boilers, heating equipment, elevator, moving stairways, electrical wiring, and flammable liquid containers. (IPMC 108.1.2) R5 - Exterior Structure x Is the exterior of the structure maintained in good repair, structurally sound and sanitary state? (IPMC 304) Fail Fail 0 R6 - Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound, and in a sanitary condition? (IPMC 305) R6.E. - Plumbing System and Fixtures Plumbing fixtures shall be properly installed and maintained in working order, and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe, sanitary and functional condition. (IPMC 504.1) Location: Electrical Location: Roof damaged and causing water to leak into building. Location: Ceiling is leaking, ceiling is damaged in bedroom and needs repaired. Toilet needs re -set on floor because it moves. Bath Faucet needs replaced. Also the ceiling on 2nd floor is sagging from possible water damage and will need looked at. Location: Toilet needs re -set on floor and bath faucet needs replaced. GENERATED ON 11/12/25, 9:58 AM 3 OF 4 Statement of Fees FEE invoice Date Inspection Fee NIA $50.00 Invoice Number N!A Date Paid Amount Paid Check Number Transaction Number N/A NIA GENERATED ON 11/12/25, 9:58 AM 4 OF 4