HomeMy WebLinkAbout272 ANSBOROUGH AVEINVOICE DATE
DUE DATE '
INVOICE #
TOTAL DUE
11/14/2025
12/19/2025
2026-00000201
$100.00
Customer #: 24835
GENERAL DYNAMICS INFORMATION -
TOWERCO - AT&T
1 EDGEWATER DR SUITE 110
CYNTHIA FORTNER
NORWOOD, MA 02062
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50 703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 272 ANSBOROUGH AVE-08/28/2025
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION 1
CUSTOMER #
24835
Total Price
$100.00
BILLING DATE
11/14/2025
DUE DATE
12/19/2025
INVOICE #
2026-00000201
CHARGES
Less Prepayment
Total Due -->
City of Waterloo
$100.00
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
1)(4
Inspection ReportOficif
Towerco - AT & T - 272 Ansborough AVE, BLDG 272 Ansborough , `enue, aterloo
IA 50703
INSPECTION DETAILS
Inspection Date Inspection Type
08/28/2025
Tanks - Flammable & Combustible Liquid Fu
Lead Inspector
JEREMIAH VANDYKE
Other Inspectors
NIA
Shift
N/A
Ott
N/A
q\\Ae
425 E. 3rd Street
Inspection Number
17250-R1
Unit
NIA
SUMMARY OF INSPECTION
0 0
Passed codes
NEXT STEPS
0 3
Failed codes
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
Reinspection Date
09/27/2025
JEREMIAH VANDYKE - 08/28/2025 @ 14:26
We have not received any data from the Manufacturer. I will reach out again for an update. I have not been up there yet to fix the Estop. It is not necessary
to go back out at this time. Thanks, Kenneth Johnson Construction Supervisor General Dynamics Wireless Services T 816-225-4711 j M 775-508-6020
Kenneth.johnson2@gdit.com www.gdit.com www.gdit.com From: Jeremiah VanDyke <Jeremiah.VanDyke@WATERLOO-IA.ORG> Sent: Wednesday,
August 27, 2025 9:23 AM To: Johnson, Kenneth 2 cKenneth.Johnson2@gdit.com>; Fortner, Cindi <Cynthia.Fortner@gdit.com> Cc: Hensley, Donald
<Donald.Hensley@gdit.com>; Lenoard, Mitchell W <Mitch.Lenoard@gdit.com>; CARRASCO, MICHELLE A <me2485@att.com> Subject: Re: 272
Ansborough Waterloo Iowa
JEREMIAH VANDYKE - 08/28/2025 @ 14:27
Replied with: Jeremiah VanDykeJohnson, Kenneth 2<Kenneth.Johnson2@gdit.com>;Fortner, Cindi <Cynthia.Fortner@gdit.com>Hensley, Donald
Donald.Hensley@gdit.com>:Lenoard, Mitchell W <Mitch.Lenoard@gdit.com>;CARRASCO, MICHELLE A <me2485@att.com>Thank you for the update.
There will be a re inspect fez starting at $103.00, then 150.00, then up to $200.00 every 30 Days. The contractor who is on the Permit will be assessed the
fee. The name on the permit is Cynthia Fortner of 1 Edgewater Drive, Ste. 110, Norwood, MA 02062. This Permit has been open since April 5th 2024.
Please contact me if you have any questions. Thank you for your time. Lieutenant J.D. Van Dyke Fire Investigator/Fire Inspector Waterloo Fire Rescue
JEREMIAH VANDYKE - 08/28/2025 @ 14:31
Re inspect Fee: $100.00 billed to "General Dynamics Information - Cynthia Fortner". Address: 1 Edgewater Drive, Ste. 110, Norwood, MA 02062. Phone
15-314-7225
JEREMIAH VANDYKE - (37128/2025 @ 09:42
i=ront: Fortner, Cinch <Cynthia.Fortner@7gdit.com> Sent: Monday, July 14, 2025 2:35 PM To: Jeremiah VanDyke <Jeremiah.VanDyke@WATERLOO-IA.ORG>
Cc: Gross, Ashleigh D-Ashleigh.Gross@gdit.com> Subject: RE: 272 Ansborough Waterloo Iowa CAUTION: This email originated from outside the City of
Waterioo entail system. Do not click links or open unexpected attachments unless you recognize the sender and know the content is safe. Thank you for
sending this. I've fornatded everything over to our construction department to taki care of this. Thank you Cindi Fortner, GDIT Cynthia.fortnertu,gdit.com
M 615-b14-7225 Frcm:.lererniah VanDyke <Jeremiah.VanDyke(wWATERLOO-IA.ORG> Sent: Monday, July 14, 2025 2:17 PM To: Fortner, Cindi
<Cynthia.Fortner g,gdit.com> Subject: Re: 272 Ansborough Waterloo Iowa
JEREMIAH VANDYKE - 0712812025 (d@ 09:42
Jeffs email
GENERATED ON 8/28,25, 2:32 PM
1 OF 4
JEREMIAH VANDYKE - 07/28/2025 @ 09:42
Email sent 7/22/2025 from Kenneth Johnson Sir, I have requested information from the Generator Service Company about the VENT issue. 1 will update
you as soon as I get any information. The other two are easy fixes that 1 can take care when I go back to the site for the vent. Please feel free to reach out
with any questions, comments, or concerns. Thanks, Kenneth Johnson Construction Supervisor General Dynamics Wireless Services T 816-225-4711 1 M
775-508-6020 Kenneth.johnson2@gdit.com www.gdit.com www.gdit.com From: Jeremiah VanDyke <Jeremiah.VanDyke@WATERLOO-IA.ORG> Sent:
Friday, July 18, 2025 10:46 AM To: Johnson, Kenneth 2 <Kenneth.Johnson2@gdit.com>; Fortner, Cindi <Cynthia.Fortner@gdit.com> Subject: Re: 272
Ansborough Waterloo Iowa
JEREMIAH VANDYKE - 07/28/2025 @ 09:42
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed
the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees
may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 07/28/2025 @ 09:42
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 07/28/2025 @ 09:42
NO re inspect fee at this time.
SIGNATURES
Contact signature Inspector signature
No signature
NA
u-O
Kenneth Johnson - Construction Supervisor Date: JEREMIAH VANDYKE 08128/2025
CHECKLISTS
GENERATED ON 8/28/25, 2:32 PM
2 OF 4
Reinspection
Status Code
Fail
Fail
L^d
Fail
2303.2.1 - Height.
The height of the emergency disconnect switch shall be not
less than 42 inches (1067 mm) and not more than 48 inches
(1219 mm) measured vertically, from the floor level to the
activating button.
2304.3.5 - Emergency procedures.
An approved emergency procedures sign, in addition to the
signs required by Section 2305.6, shall be posted in a
conspicuous location and shall read: IN CASE OF FIRE, SPILL
OR RELEASE 1.USE EMERGENCY PUMP SHUTOFF
2.REPORT THE ACCIDENT! FIRE DEPARTMENT TELEPHONE
NO. _.. FACILITY ADDRESS
5704.2.7.3.3 - Vent pipe outlets
Vent pipe outlets for tanks storing Class I, II or IIIA liquids
shall be located such that the vapors are released at a safe
point outside of buildings and not less than 12 feet (3658 mm)
above the finished ground level. Vapors shall be discharged
upward or horizontally away from adjacent walls to assist in
vapor dispersion. Vent outlets shall be located such that
flammable vapors will not be trapped by eaves or other
obstrucftions and shall be not less than 5 feet (1524 mm) from
budding openings or lot lines of properties that can be built
on. Vent outlets on atmospheric tanks storing Class IIIB
liquids are allowed to discharge inside a building where the
vent is a normally closed vent. Exception: Vent pipe outlets
on tanks storing Class 111E liquid inside buildings and
connected to fuel -burning equipment shall be located such
that the vapors are released to a safe location outside of
buildings.
Des
Location: Per Jeff's email
Comments: Emergency Stop not mounted 42"above the floor.
Location: Per Jeffs email.
Comments: Proper signage for the emergency stop is not installed.
Location: Per Jeffs Email
Comments: Still not corrected or installed.
GENERATED ON 8/28/25, 2:32 PM
3 OF 4
Statement of Fees
FEE
Invoice Date inspection Fee
N/A $100.00
Invoice Number
N/A
Date Paid Amount Paid
Check Number Transaction Number
N/A N/A
GENERATED ON 8/28/25, 2:32 PM
4 OF 4
INC tt