Loading...
HomeMy WebLinkAbout814 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/14/2025 12/19/2025 2026-00000203 $100.00 Customer #: 24834 DALLAS FRESH 814 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 814 LAPORTE RD-10/16/2025 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24834 11/14/2025 12/19/2025 2026-00000203 $100.00 Less Prepayment Total Due City of Waterloo $0.00 S100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Dallas Fresh - 814 La Porte RD, BLDG 814 La Porte Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection D64, 10/16/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) REINSPECTION Other Inspectors N/A Shift N/A 425 E. 3rd Street Inspection Number 11796-R2 Station Unit N/A N/A SUMMARY OF INSPECTION 0 0 2 Passed codes Resolved violations NEXT STEPS 08 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/2512025 @ 15:17 $80 annual inspection fee BRAD BALDWIN - 09/2512025 @ 15:17 Fire extinguishers due annually serviced by January 2026 BRAD BALDWIN - 09/25/2025 @ 15:17 Specific questions regarding electrical requirements shall be directed to Electrical Inspector, Tim Moyer at 319-464-5683. BRAD BALDWIN - 09125/2025 @ 15:17 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 09/25/2025 @ 15:17 Reinspection Date 11110/2025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 09/25/2025 @ 15:17 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 09/25/2025 @ 15:17 Withholding re -inspection today 9/25/25 due to significant progress made. Provide record of electrical work completed by licensed electrical contractor. BRAD BALDWIN - 10/16/2025 @ 15:32 $100 re -inspection fee, failure to correct violations BRAD BALDWIN - 10/16/2025 @ 15:41 Per City Clerk's Office: Liquor license invalid as of 10116/25, alcohol shall be removed from building without valid liquor license. GENERATED ON 10/17/25, 8:19 AM 1 OF 8 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection EES ALBERTO BALTIERRA Date: BRAD BALDWIN 10117/2025 CHECKLISTS GENERATED ON 10/17/25, 8:19 AM 2 OF 8 Reinspection Status Code Fail 0 Fail 0 Fail 601.2 - Hazard abatement. Operations or conditions deemed unsafe or hazardous by the fire code official shall be abated. Equipment, appliances, materials and systems that are modified or damaged and constitute an electrical shock or fire hazard shall not be used. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Description Location: Walk in fridge Comments: Cord unprotected from sharp metal edge should be corrected to avoid shock hazard. Appliance cord and or plug end altered, licensed electrical contractor shall inspect, repair or replace. Copy of receipt of work completed shall be kept to show inspector. Additional comments: No progress today Location: Hallway to mechanical room light fixtures Comments: Light fixture wiring shall be inspected by licensed electrical contractor, repaired or replaced . Copy of receipt of work completed shall be kept to show inspector. Additional comments: No progress today Location: Beverage fridge in front of bar Comments: Appliance cord and or plug end altered, licensed electrical contractor shall inspect, repair or replace. Copy of receipt of work completed shall be kept to show inspector. Additional comments: No progress today GENERATED ON 10/17/25, 8:19 AM 3 OF 8 Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 606.3.3.1- Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Bar electric panel closet Comments: Cord installation not approved, staff unsure of use of cord. Repair or replace by licensed electrical contractor. Additional comments: No progress today Location: Kitchen hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 2 days past due as of 8/26/25. Additional comments: Deficiencies per Compliance Engine report #8039437 states "appliances have been rearranged or added" shall be corrected. GENERATED ON 10/17/25, 8:19 AM 4 OF 8 Additional Codes Status Code Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Description Location: Electric panel Comments: Remove obstructions to access electric panels GENERATED ON 10/17/25, 8:19 AM 5 OF 8 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: Stage area Comments: Remove power strip plugged to another power strip, shall be directly plugged to wall outlet. Green cube adapter not approved for commercial use. GENERATED ON 10/17/25, 8:19 AM 6 OF 8 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Stage area near back door Comments: Repeat violation: Remove concealed cord from above ceiling. Will require to see cord in full removed. GENERATED ON 10/17/25, 8:19 AM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Pee NIA $100.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 10/17/25, 8:19 AM 8 OF 8