Loading...
HomeMy WebLinkAbout814 LA PORTE RD (2)INVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/14/2025 12/19/2025 2026-00000202 $80.00 Customer #: 24834 DALLAS FRESH 814 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 814 LAPORTE RD-08/25/2025 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24834 11/14/2025 12/19/2025 2026-00000202 $80.00 Less Prepayment Total Due —+ City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Dallas Fresh - 814 La Porte RD, BLDG 814 La Porte Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 08125/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA SUMMARY OF INSPECTION ® 40 Passed codes NEXT STEPS 0 23 Failed codes 23 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad-baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/26/2025 0 07:28 $80 annual inspection fee BRAD BALDWIN - 08/2612025 @ 08:02 Fire extinguishers due annually serviced by January 2026 Shift NIA Station NIA 425 E. 3rd Street Inspection Number 11796 BRAD BALDWIN - 08/26/2025 @ 10:04 Specific questions regarding electrical requirements shall be directed to Electrical Inspector, Tim Moyer at 319-464-5683. BRAD BALDWIN - 08/2612025 @ 10:06 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 08/26/2025 @ 10:06 Unit NIA Reinspection Date 09/22/2025 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/26/2025 @ 10:06 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections 8 re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection are ALBERTO BALTIERRA Date: BRAD BALDWIN 08/2.6/2025 GENERATED ON 8/26/25, 10'16 AM 1 OF 15 CHECKLISTS Fire Service Features Status Fail 0 Cady 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. ptlof Location: Kitchen suppression system pull handle Comments: Remove equipment obstructing access to suppression system pull handle, maintain clear path. GENERATED ON 8/26/25, 10:16 AM 2 OF 15 Additional Codes stasis Code Fail Fail 601.2 - Hazard abatement. Operations or conditions deemed unsafe or hazardous by the fire code official shall be abated. Equipment, appliances, materials and systems that are modified or damaged and constitute an electrical shock or fire hazard shall not be used. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Location: Walk in fridge Comments: Cord unprotected from sharp metal edge should be corrected to avoid shock hazard. Appliance cord and or plug end altered, licensed electrical contractor shall inspect, repair or replace. Copy of receipt of work completed shall be kept to show inspector. Location: Food warmer near front entrance Comments: Appliance cord and or plug end altered, licensed electrical contractor shall inspect, repair or replace. Copy of receipt of work completed shall be kept to show inspector. Location: Hallway to mechanical room light fixtures Comments: Light fixture wiring shall be inspected by licensed electrical contractor, repaired or replaced . Copy of receipt of work completed shall be kept to show inspector. Location: Beverage fridge in front of bar Comments: Appliance cord and or plug end altered, licensed electrical contractor shall inspect, repair or replace. Copy of receipt of work completed shall be kept to show inspector. GENERATED ON 8/26/25, 10:16 AM 3 OF 15 Fail 606.2 - Where required. A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 71013, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mglm3 or Tess of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3/s) in accordance with UL 71013. Location: Kitchen exhaust hood and appliances Comments: Relocate cooking equipment producing grease laden vapors to be within 6 inches inside of outer edges of hood exhaust system. Grill top on left side being used as "table" may stay in place if disconnected from gas service. GENERATED ON 8/26/25, 10:16 AM 4 OF 15 Electrical Safety State; Code Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Above table dining area Comments: Concealed connection above ceiling tiles not approved, repair or replace by licensed electrical contractor with obtaining permit and inspection. GENERATED ON 8/26/25, 10:16 AM 5 OF 15 Fail Fail 0 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Bar electric panel closet Comments: Cord installation not approved, staff unsure of use of cord. Repair or replace by licensed electrical contractor. Location: Mechanical room light switch Comments: Install missing switch cover GENERATED ON 8/26/25, 10:16 AM 6 OF 15 Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Ceiling outlet above table dining area Comments: Install missing outlet cover. GENERATED ON 8/26/25, 10:16 AM 7 OF 15 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.4.1 - Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Location: Mechanical room electric panel Comments: Remove shelf and cart obstructing access to panels, maintain 36" clearance in front of panel and clear access at all times. Location: Electric panel closet near bar Comments: Install permanent sign on door reading "Electrical Room", red sign with white lettering. Laminated paper will not be accepted. GENERATED ON 8/26/25, 10:16 AM 8 OF 15 Fail O Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Behind front counter Comments: Green multi -plug cord shall be removed. Power strip with manual reset shall be plugged directly to wall outlet used for light duty electric. Location: Bar behind cash register Comments: Remove multi -plug adapters. May replace with properly mounted or supported power strip with manual reset for light duty electric. Adding outlet requires licensed electrical contractor to obtain permit and inspection. GENERATED ON 8/26/25, 10:16 AM 9 OF 15 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Above front entrance Comments: Remove brown extension cord hanging through ceiling tiles. Extension cords not permitted for permanent use, additional outlets installed as needed will require a licensed electrical contractor to obtain permits and inspections. Location: Produce cooler Comments: Relocate cooler cord running across walkway to avoid trip hazard and possible damage, or provide UL listed floor cord protector, or provide electric service from above by licensed electrical contractor by obtaining permits and inspections. GENERATED ON 8/26/25, 10:16 AM 10 OF 15 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind front counter Comments: Remove green extension cord running across walkway. Additional outlets installed requires licensed electrical contractor to obtain permits and inspections. GENERATED ON 8/26/25, 10:16 AM 11 OF 15 Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Mechanical room chest freezer Comments: Remove green extension cord plugged to freezer. Freezer shall be plugged directly to wall outlet. Location: Near back entrance and stage Comments: Remove yellow extension cord hanging through ceiling tiles. Extension cords not permitted for permanent use, additional outlets installed as needed will require a licensed electrical contractor to obtain permits and inspections. GENERATED ON 8/26/25, 10:16 AM 12 OF 15 Commercial Cooking Hood Suppression System Stu; Coale Fail Fail Fail 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 606.3.3.2 - Grease accumulation. If during the inspection it is found that hoods, grease -removal devices, fans, ducts or other appurtenances have an accumulation of grease, such components shall be cleaned in accordance with ANSI/IKECA C10. Location: Kitchen hood exhaust cleaning Comments: Provide hood cleaning and inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 2 days past due as of 8/26/25. Location: Kitchen hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 2 days past due as of 8/26/25. Location: Kitchen hood exhaust filters Comments: Clean grease filters, currently has build up of accumulation. GENERATED ON 8/26/25, 10:16 AM 13 OF 15 Fire Resistant Construction Maintenance Status Fail 0 Code 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Mechanical room Comments: Replace missing ceiling tiles above water heater and door to mechanical room. GENERATED ON 8/26/25, 10:16 AM 14 OF 15 Statement of Fees FEE Invoice Date rwr,lion Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 8/26/25, 10:16 AM 15 OF 15