Loading...
HomeMy WebLinkAbout4051 UNIVERSITY AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/14/2025 12/19/2025 2026-00000204 $150.00 Customer #: 24833 JEOVAH JIREH CHURCH 4051 UNIVERSITY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 4051 UNIVERSITY AVE-09/05/2025 FOR BILLING INQUIRY: (319)291-4323 Description, REINSPECTION 2 Total Price $150.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24833 11/14/2025 12/19/2025 2026-00000204 $150.00 Less Prepayment Total Due —> City of Waterloo $0.00 $150.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Jeovah Jireh Church - 4051 University AVE, BLDG 4051 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 09105/2025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) I REINSPECTION Other inspectors NIA Shift NIA 425 E. 3rd Street Inspection Number 7418-R3 Station Unit NIA N/A SUMMARY OF INSPECTION Q 0 Passed codes NEXT STEPS 0.19 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/08/2025 @ 12:46 $150 re -inspection fee, failure to correct violations as of 9/5/25. BRAD BALDWIN - 08/18/2025 @ 06:46 $100 re -inspection fee, failure to show for scheduled inspection on 6/23125 at 1:30pm. BRAD BALDWIN - 08/18/2025 @ 06:46 Reinspection Date 10/07/2025 -Re-inspection dates are automatically generated 30 days out from the initial inspection. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. - BRAD BALDWIN - 08/18/2025 @ 06:46 -Property Safety Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 BRAD BALDWIN - 08/18/2025 @ 06:46 $80 Annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection John Latdrik (Pastor) Date: BRAD BALDWIN 09/08/2025 CHECKLISTS GENERATED ON 9/8/25, 1.24 PM 1 OF 7 Reinspection Status Code Fail Fail Fail Fail Fail x Fail Fail Fail 1004.9 - Posting of occupant load. Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space, for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. 102.3 - Change of use or occupancy. A change of occupancy shall not be made unless the use or occupancy is made to comply with the requirements of this code and the International Existing Building Code Exception: Where approved by the fire code official, a change of occupancy shall be permitted without complying with the requirements of this code and the International Existing Building Code , provided that the new or proposed use or occupancy is less hazardous, based on life and fire risk, than the existing use or occupancy. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 5.2.1 - Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor Description Location: Occupant load posting Comments: Occupant load shall be reviewed by licensed designed professional. Report shall be sent to fire inspector. Location: Change of occupancy Comments: Change of occupancy must be reviewed by a licensed design professional. Report by professional shall be submitted to be reviewed by City Building Official. Location: Walls constructed in SE corner Comments: Walls constructed without building permit. Obtain architect to submit plans for review of by City Building Official Location: Walls constructed outside women's bathroom Comments: Walls constructed without building permit. Obtain architect to submit plans for review of by City Building Official Location: Wall constructed separating church from south area of building Comments: Wall constructed without building permit. Obtain architect to submit plans for review by of by City Building Official. Location: Exit sign near alter Comments: Exit light above front entrance doors failed testing, repair or replace. Location: Front entrance exit light Comments: Exit light above front entrance doors failed testing, repair or replace. Location: Sprinkler system Comments: Complete sprinkler system testing and inspection, currently past due 578 days as of 5/13/25. Contractor must upload report online to Compliance Engine GENERATED ON 9/8/25, 1:24 PM 2 OF 7 Fail Fail Fail Fail Fail 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. 509.2 • Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Northwest corner sprinkler escutcheon Comments: Install sprinkler escutcheon properly Location: Sprinkler riser room Comments: Remove all storage. Location: All multiplug adapters and cords Comments: Multiplug adapters and multiplug cords shall be removed. Location: All power strips Comments: All power strips shall be plugged directly to wall receptacle. Location: Near posts in center of building and near front wall. Comments: Cords running through ceiling grids shall be permanently removed. Location: Several extension cords noted Comments: Remove all extension cords. GENERATED ON 9/8/25, 1:24 PM 3 OF 7 Fail 807.2 - Combustible decorative materials. In Groups A, B, E, 1, M and R-1 and in dormitories in Group R- 2, curtains, draperies, fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached. Fixed or movable walls and partitions, paneling, wall pads and crash pads applied structurally or for decoration, acoustical correction, surface insulation or other purposes shall be considered to be interior finish, shall comply with Section 803 and shall not be considered decorative materials or furnishings. Exceptions: 1.In auditoriums in Group A, the permissible amount of curtains, draperies, fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the budding is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, and where the material is installed in accordance with Section 803.15 of the International Building Code. 2.In Group R-2 dormitories, within sleeping units and dwelling units, the permissible amount of curtains, draperies, fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1. 3.In Group B and M occupancies, the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited. 4.The 10-percent limit shall not apply to curtains, draperies, fabric hangings and similar combustible decorative materials used as window coverings. Location: Wall coverings near alter Comments: Verify draperies meet flame spread requirements GENERATED ON 9/8/25, 1:24 PM 4 OF 7 Fail 906.1- Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H, 1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C. 2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C. 3. In storage areas of Group S occupancies where forklift, powered industrial truck or powered cart operators are the primary occupants, fixed extinguishers, as specified in NFPA 10, shall not be required where in accordance with all of the following: 3.1. Use of vehicle -mounted extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10- pound, 40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on -site to replace a discharged extinguisher. 3.4. Vehicle operators shall be trained in the proper operation, use and inspection of extinguishers. 3.5. Inspections of vehicle - mounted extinguishers shall be performed daily. 2.Within 30 feet (9144 mm) distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1- 1; 1-2, Condition 1; and R-2 college dormitory occupancies. 3.In areas where flammable or combustible liquids are stored, used or dispensed. 4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1. 5.Where required by the sections indicated in Table 906.1. 6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Fail Chapter 14 - Inspection, testing, and maintenance 0 Fire alarm system tested at least annually by licensed contractor Fail Table 8.1.1.2 - Fire pump inspection, testing, and maintenance Fire pump being tested (run)? Weekly for diesel/monthly for electric. Location: Fire extinguishers Comments: Install fire extinguishers where required by code. Copy of receipt shall be kept for purchase of fire extinguishers Location: Fire alarm system Comments: Complete fire alarm system testing and inspection, currently past due 388 days as of 5/13/25. Contractor must upload report online to Compliance Engine Location: Sprinkler system testing & inspection Comments: Complete sprinkler system testing and inspection, currently past due 578 days as of 5/13125. Contractor must upload report online to Compliance Engine. GENERATED ON 9/8/25, 1:24 PM 5 OF 7 Additional Codes Stares Code Fail 114.1.1- Unsafe conditions. Structures or existing equipment that are or hereafter become unsafe, insanitary or deficient because of inadequate means of egress, inadequate light and ventilation, or that constitute a fire hazard, are otherwise dangerous to human life or the public welfare, or involve illegal or improper occupancy or inadequate maintenance, shall be deemed an unsafe condition. Unsafe structures shall be taken down and removed or made safe, as the fire code official deems necessary and as provided for in this section. A vacant structure that is not secured against unauthorized entry as required by Section 311 shall be deemed unsafe. Description Comments: Suite shall remain unoccupied due to inoperable fire alarm system. Repair of alarm and made operable by licensed contractor shall upload report to Compliance Engine. Notice of "Do Not Occupy" posted today on front door of suite (918125). GENERATED ON 9/8/25, 1:24 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee NIA $150.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 9/8/25, 1:24 PM 7 OF 7