COMMERCIAL INSPECTION - 1307 W RIDGEWAY AVE-09/04/2025
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 20,000
OCCUPANCY FEE
Total Price
$90.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24832
11/14/2025
12/19/2025
2026-00000205
$100.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
INSPECTION DETAILS
n 53 pection Date
09/04/2025
Waterloo Fire Rescue
Inspection Report
Diamond Star Academy - 1307 W Ridgeway AVE, BLDG 1307 W Ridgeway A i
,..x
Waterloo IA 50701
Lead Inspector
JEREMIAH VANDYKE
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
BROCK WELIVER, BRAD BALDWIN
Shift
NIA
�c.
Station
N/A
425 E. 3rd Street
Inspection Number
11554
Unit
NIA
SUMMARY OF INSPECTION
044
Passed codes
NEXT STEPS
(X) 14
Failed codes
18
NIA codes
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE - 09/04/2025 @ 15:50
Fire drill scheduled for 9/8/2025.
JEREMIAH VANDYKE - 09/04/2025 @ 15:52
Boilers inspection expires 1131/2026. Discussed contacting Iowa department of inspections and appeals.
JEREMIAH VANDYKE - 09/04/2025 @ 15:58
Fire extinguishers serviced by Proshield July 2025.
JEREMIAH VANDYKE - 09/0412025 @ 16:15
7/21/2025 S - (Semi -Annual) Kitchen Exhaust PROSHIELD FIRE & SECURITY Reviewed Compliant
JEREMIAH VANDYKE - 09/04/2025 @ 16:15
7/2112025 S - Kitchen Hood Suppression PROSHIELD FIRE & SECURITY Reviewed Deficient
JEREMIAH VANDYKE - 09104/2025 @ 16:15
7/14/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant
Reinspection Date
10/05/2025
JEREMIAH VANDYKE - 09105/2025 @ 08:09
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed
the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. ****"Re inspection fees
may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 0910512025 @ 08:09
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 09/0512025 @ 08:10
Inspection Fee = $100.00 (To be mailed out by City via snail mail.)
GENERATED ON 9/5/25, 8:11 AM 1 OF 6
SIGNATURES
Contact signature
No signature
Report completed post inspection
Jami Nott - Principal Date:
CHECKLISTS
Emergency Equipment
statu; code
Fail
Fail
Inspector signature
JEREMIAH VANDYKE
1203.2.15 - Means of egress illumination.
Emergency power shall be provided for means of egress
illumination in accordance with Sections 1008.3 and 1104.5.1.
1203.2.6 - Exit signs.
Emergency power shall be provided for exit signs as required
in Section 1013.6.3. The system shall be capable of powering
the required load for a duration of not less than 90 minutes.
Fire Alarm System
Fail
2015 IFC - Fire alarm testing and maintenance
Is the fire alarm system powered, operational and displaying
normal operation (no troubles, supervisory, or alarms)?
Additional Codes
Status
Fail
308.1.4 - Open -flame cooking devices.
Charcoal burners and other open -flame cooking devices shall
not be operated on combustible balconies or within 10 feet
(3048 mm) of combustible construction. Exceptions: 1.One-
and two-family dwellings. 2.Where buildings, balconies and
decks are protected by an automatic sprinkler system. 3.LP-
gas cooking devices having LP -gas container with a water
capacity not greater than 21/ 2 pounds [nominal 1 pound
(0.454 kg) LP -gas capacity].
Description
Location: Women's locker room
09/05/2025
Comments: Egress light tested and failed. Discussed getting licensed
electrician to repair or replace egress or exit lights.
Location: 1. Rooms 124. 2. Main hallway near room 114 Exit light
missing. 3. All exit lights in Gym. 4. Choir room. 5. Main entrance/exit
of the church in lobby area. 6. Door C exit liht
Comments: Exit light tested and failed. Discussed getting licensed
electrician to repair or replace egress or exit lights.
Des cri n, e 0'i i
Location: Alarm in Trouble.
Comments: Need to contact fire alarm contractor as soon as possible
to address panel. Advised principal to check panel every morning to
address any issues with panel.
Description
Location: Remove gas grill and LP tank from inside of school area.
Comments: Remove gas grill and LP tank from inside of school area.
GENERATED ON 9/5/25, 8:1.1 AM 2 OF 6
Documentation
Status Code
Fail
Fail
403.4.1 - First emergency evacuation drill.
The first emergency evacuation drill of each school year shall
be conducted within 10 days of the beginning of classes.
404.2.1 - Fire evacuation plans.
Fire evacuation plans shall include the following:
1.Emergency egress or escape routes and whether
evacuation of the building is to be complete by selected
floors or areas only or with a defend -in -place response.
2.Procedures for employees who must remain to operate
critical equipment before evacuating. 3.Procedures for the
use of elevators to evacuate the building where occupant
evacuation elevators complying with Section 3008 of the
International Building Code are provided. 4.Procedures for
assisted rescue for persons unable to use the general means
of egress unassisted. 5.Procedures for accounting for
employees and occupants after evacuation has been
completed. 6.Identification and assignment of personnel
responsible for rescue or emergency medical aid. 7.The
preferred and any alternative means of notifying occupants of
a fire or emergency. 8.The preferred and any alternative
means of reporting fires and other emergencies to the fire
department or designated emergency response organization.
9.Identification and assignment of personnel who can be
contacted for further information or explanation of duties
under the plan. 10.A description of the emergency voicelalarm
communication system alert tone and preprogrammed voice
messages, where provided.
Fire Service Features
Status Code
Fail
\:J
506.1 - Where required.
Where access to or within a structure or an area is restricted
because of secured openings or where immediate access is
necessary for life-saving or fire -fighting purposes, the fire
code official is authorized to require a key box to be installed
in an approved location. The key box shall be of an approved
type listed in accordance with UL 1037, and shall contain
keys to gain necessary access as required by the fire code
official.
Location: Need to complete first fire drill of the year and be recorded.
Comments: Need to complete first fire drill of the year and be
recorded.
Location: Fire evac plans needed in classrooms, office, gym and
where students are occupying.
Description
Location: Door C knox box key
Comments: Master key in Knox box will not open Door C. Advised on
contacting B&B lock to address lock issue.
GENERATED ON 9/5/25. 8:11 AM 3 OF 6
Electrical Safety
status Code
Fail
Fail
0
Fail
0
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
ipnon
Location: Outlet left of stove in kitchen needs replaced. Has Arching
around plug in.
Comments: Outlet left of stove in kitchen needs replaced. Has
Arching around plug in.
Location: Kitchen floor outlet.
Comments: Need to have open holes on electrical box covered with
appropriate electrical caps.
Location: Left of gym stage.
Comments: Missing outlet cover needs to be replaced.
Location: Above Stage area in gym
Comments: White and grey extension cords on both sides need to be
removed.
Location: Old 2nd floor Nursing room.
Comments: Orange extension cord running through ceiling that
needs removed.
GENERATED ON 9/5/25, 8:11 AM 4 OF 6
Fire Resistant Construction Maintenance
Status Code
Fail
Fail
704.1 - Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floortceiling assemblies and roof or
roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
705.2 - Inspection and maintenance.
Opening protectives in fire -resistance -rated assemblies shall
be inspected and maintained in accordance with NFPA 80.
Opening protectives in smoke barriers shall be inspected and
maintained in accordance with NFPA 80 and NFPA 105.
Openings in smoke partitions shall be inspected and
maintained in accordance with NFPA 105. Fire doors and
smoke and draft control doors shall not be blocked,
obstructed, or otherwise made inoperable. Fusible links shall
be replaced promptly whenever fused or damaged. Opening
protectives and smoke and draft control doors shall not be
modified.
i) : scription
Location: Missing Ceiling Tiles: 1. Room 102. 2. Cafetiria. 3. Rooms
215, 217, & 205. 4. Near prayer room. 5. Recess Room. 6. Ramp near
gym.
Comments: Missing multiple ceiling tiles that need replaced and
maintained throughout building.
Location: Double doors in hallway near room #114.
Comments: Need to remove door stops.
GENERATED ON 9/5/25, 8:11 AM 5 OF 6