Loading...
HomeMy WebLinkAbout1816-1818 WILLISTON AVE STE 18180 Customer #: 24829 SWITCH NUTRITION 1818 WILLISTON AVE WATERLOO, IA 50702 2026-00000209 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -1816-1818 WILLISTON AVE. STE 1818 -09/04/ IFOR BILLING INQUIRY: (319)291-4323 1 Description Total Price I INSPECTION 2,000 OCCUPANCY FEE CUSTOMER # BILLING DATE 24829 1 11 / 14/2025 DUE DATE 12/19/2025 City of Waterloo INVOICE'# 2026-00000209 Less Prepayment Total Due —> $70.00 $10.00 CHARGES $80.00 $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Switch Nutrition - 1816-1820 Williston AVE, BLDG 1816 Williston Ave - STE 1818, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 09/04/2025 Lead Inspector BRAD BALDWIN Other Inspectors N/A Inspection Type Annual Inspection (1Yr) Shift NIA 425 E. 3rd Street Inspection Number 17598 Station Unit N/A N/A SUMMARY OF INSPECTION 0 34 Passed codes NEXT STEPS 6 Failed codes 35 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/04/2025 @ 12:41 $80 annual inspection fee. BRAD BALDWIN - 09/04/2025 @ 13:16 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 09/04/2025 @ 13:17 Reinspection Date 10/10/2025 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Brendon Brown Date: CHECKLISTS BRAD BALDWIN 09/1112025 GENERATED ON 9/11/25, 7:25 AM 1 OF 5 Means of Egress Status Code Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Status Code Fail Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Desuription Location: Back exit Comments: Remove all obstructions to path of egress to exit path. Note: not required to maintain path of egress if exit sign is properly removed or covered as stated in violation 1203.2.6 "Exit Signs" Description Location: Front entrance Comments: Repair or replace exit sign that failed to illuminate during test. Location: Back entrance Comments: Second exit not required due to occupancy load, options: (1) Repair or replace exit sign that failed to illuminate during test. (2) Remove exit sign, properly cap wires in covered box or (3) provide proper cover to exit sign. GENERATED ON 9/11/25, 7:25 AM 2 OF 5 Electrical Safety Status Code Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Descriprion Location: Electric panel closet near back exit Comments: Replace damaged outlet and provide proper outlet cover. Location: Bar area Comments: Remove coffee maker and label machine from power strip, appliances with heating elements shall be plugged directly to wall outlet. Power strips allowed for light duty electric only. If adding outlet, licensed electrical contractor must obtain proper permit and inspections. GENERATED ON 9/11/25, 7:25 AM 3 OF 5 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Back storage area near utility sink Comments: Provide annual service to fire extinguisher, most current service completed in 2022. GENERATED ON 9/11/25, 7:25 AM 4 OF 5 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 9/11/25, 7:25 AM 5 OF 5