Loading...
HomeMy WebLinkAbout313 W 5TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/14/2025 12/19/2025 2026-00000195 $80.00 Customer #: 21928 CLUB AMBASSADOR 313 W 5TH ST WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 313 W 5TH ST-10/28/2025 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # 21928 BILLING DATE 11/14/2025 DUE DATE 12/19/2025 INVOICE # 2026-00000195 CHARGES $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Club Ambassador - 313 W 5th ST, BLDG 313 W 5th St, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 10/2812025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Othe, Inspectors N/A 425 E. 3rd Street Inspection Number 15323 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 039 05 Passed codes Failed codes NEXT STEPS 0 30 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 10/28/2025 @ 14:50 $80 annual inspection fee BRAD BALDWIN - 10/28/2025 @ 14:54 Corrected during 10/28/25 inspection: Removed power strip daisy chained to another power strip. BRAD BALDWIN - 10/28/2025 @ 15:03 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 11/2012025 BRAD BALDWIN - 10/28/2025 @ 15:03 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 10/28/2025 @ 15:03 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Nedzad Rekic (2025) Date: BRAD BALDWIN 10/28/2025 CHECKLISTS GENERATED ON 10/28/25. 3:05 PM 1 OF 6 S Electrical Safety Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4.1 - Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Description Location: Women"s restroom Comments: Provide proper blank covering to opening in electric panel to avoid shock hazard. Location: Women"s restroom Comments: Provide permanent sign on restroom door stating "Electric Room", sign shall be red with white lettering. Laminated paper will not be accepted. GENERATED ON 10/28/25, 3:05 PM 2 OF 6 Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Location: Above bar Comments: Remove power strip from black extension cord. Power strip must be plugged directly to wall outlet for light duty electric only. GENERATED ON 10/28/25, 3:05 PM 3 OF 6 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Comments: Provide annual service to all fire extinguishers. Last current service completed October 2024. GENERATED ON 10/28/25, 3:05 PM 4 OF 6 Fail 906.7 - Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Location: Bar Comments: Properly hang fire extinguisher on wall bracket between 4 inches to 5 feet from floor. GENERATED ON 10/28/25, 3:05 PM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 10/28/25, 3:05 PM 6 OF 6