Loading...
HomeMy WebLinkAbout315 FLETCHER AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/16/2025 01/19/2026 2026-00000263 $80.00 Customer #: 21671 NEW STAR 315 FLETCHER AV WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed.• DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 315 FLETCHER AVE - 12-15-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 21671 BILLING DATE 12/16/2025 DUE DATE 01/19/2026 INVOICE # 2026-00000263 CHARGES $80.00 Less Prepayment Total Due --> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. rUl Waterloo Fire Rescue Inspection Report New Star - 315 Fletcher AVE, BLDG 315 Fletcher Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 12115/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA Shih NIA 425 E. 3rd 5trem Inspection Number 16111 Station Unit NIA NIA SUMMARY OF INSPECTION 038 Q7 Passed codes Failed codes NEXT STEPS 30 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 12/15/2025 @ 14:41 • $80 annual inspection fee BRAD BALDWIN - 12/15/2025 @ 15:05 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 01/08/2026 BRAD BALDWIN - 12/15/2025 @ 15:05 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 12/15/2025 @ 15:06 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Sunny Hadyat CHECKLISTS No signature Report completed post inspection 1'0 Date: BRAD BALDWIN 12/15/2025 GENERATED ON 12/15/25, 3:15 PM 1 OF 6 Emergency Equipment Status Code Fail Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. General Housekeeping Status Code Fail 305.1- Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Description Location: North exit Comments: Repair or replace exit sign and egress lights that failed to illuminate during test. Location: West (main exit) Comments: Repair or replace exit sign and egress lights that failed to illuminate during test. Description Location: Mechanical room near north exit Comments: Remove combustible storage from within 36" of furnace, maintain clearance at all times. Additional Codes Status Code Description Fail 603.1- General. l Electrical equipment, wiring and systems required by this Location: Microwave near arcade game code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. Comments: Microwave shall be plugged directly to wall outlet. Currently plugged to power strip. GENERATED ON 12/15/25, 3:15 PM 2 OF 6 ''Electrical Safety Status Code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Walk-in fridge Comments: Make necessary repairs to light fixture. GENERATED ON 12/15/25, 3:15 PM 3 OF 6 Fail l:J 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Electric panel Comments: Remove storage from within 36" in front of panel. Maintain clearance at all times. GENERATED ON 12/15/25, 3:15 PM 4 OF 6 Portable Fire Extingusihers Status Code Fail 0 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verity that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Comments: Provide annual service to fire extinguishers, past due as of March 2025. GENERATED ON 12/15/25, 3:15 PM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 12/15/25, 3:15 PM 6 OF 6