Loading...
HomeMy WebLinkAbout1422 FLAMMANG DR (2)Customer #: 4706 HY-VEE #3 1422 FLAMMANG DR WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/16/2025 01/19/2026 2026-00000271 $235.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1422 FLAMMANG - 12-16-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 50,000 OCCUPANCY FEE $225.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE# CHARGES 4706 12/16/2025 01/19/2026 2026-00000271 $235.00 Less Prepayment Total Due — > City of Waterloo $0.00 $235.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Hy-Vee - 1422 Flammang DR, BLDG 1422 Flammang Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 12116/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 16404 5hifl Station Unit NIA NIA NIA SUMMARY OF INSPECTION 051 024 ®7 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 12117/2025 @ 08:38 $235 annual inspection fee BRAD BALDWIN - 12/17/2025 @ 09:23 Kitchen hood cleaning due for service 1128126. BRAD BALDWIN - 12/1712025 @ 11:30 Fire extinguishers due annually serviced by April 2026 BRAD BALDWIN - 12/17/2025 @ 12:21 Egress Lights and Exit Sign report from ab...a<iwet at man ar a rang , ask artbckwsdearu�arkM Nrvapwoasteaa. AL eeuix!e i:re dour altN ieare( Wont plrrb,. Atave main ehvantt to parkwig �qla WMe 8 igeki: Ahove p,Mw;e w rk slack area bV drop door. A iea Or {ae aaW[on Auave4MGipdow. above .svAngdwan.Aa4e awln hW wav- .... My Vee Fvo Store+ 42$➢kmmang Drive taScrfuo, lA So707 Reinspection Date 01/13/2026 GENERATED ON 12/18/25, 2:55 PM 1 OF 15 BRAD BALDWIN - 12/17/2025 @ 12:30 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 12/17/2025 @ 12:30 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 12/17/2025 @ 12:30 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. ***"*Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Dave Bowling CHECKLISTS No signature Report completed post inspection n Date: BRAD BALDWIN 12/1712025 GENERATED ON 12/18/25, 2:55 PM 2 OF 15 Means of Egress Status Code Fail Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Description Location: Exit door near trash compactor Comments: Repair or replace exit door. Exit door must unlatch and swing to full open with less than 15 lbs of force. If replaced obtain permits and inspections. Location: Liquor store Comments: Remove obstructions to end of aisle or have licensed design professional review and provide report to inspector. GENERATED ON 12/18/25, 2:55 PM 3 OF 15 Emergency Equipment Status Code Fail l^J 1203.4.3 - Records. Records of the inspection, testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician, a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Description Location: Back-up generator Comments: Provide GENERATED ON 12/18/25, 2:55 PM 4 OF 15 Fire Sprinkler System Status Code Fail a Fail a Fail a 5.2.1 - Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Description Location: Sprinkler system Comments: Sprinkler system will be past due for annual service prior to re -inspection as of 1/8/26. Provide annual inspection report with any deficiencies corrected, contractor must upload report to Compliance Engine. Location: Market Grill Kitchen & Deli Comments: Carefully remove dust build-up on multiple sprinkler heads. Location: Old can redemption area Comments: Remove storage within 18" of sprinkler heads GENERATED ON 12/18/25, 2:55 PM 5 OF 15 Fail Fail Fail 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not Tess than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. 903.3.3 - Obstructed locations. Automatic sprinklers shall be installed with regard to obstructions that will delay activation or obstruct the water distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used. Automatic sprinklers shall be installed in or under covered kiosks, displays, booths, concession stands or equipment that exceeds 4 feet (1219 mm) in width. Not less than a 3-foot (914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire -extinguishing system in accordance with Section 904. Location: Customer service above lottery machine. Comments: Carefully remove dust build-up on multiple sprinkler heads. Location: Caleb's office (upper level) Comments: Carefully remove dust build-up on multiple sprinkler heads. Comments: An hanging displays obstructing spray patterns of sprinkler head distribution shall be removed or lowered to 18" below sprinkler heads . GENERATED ON 12/18/25, 2:55 PM 6 OF 15 Fire Service Features Status Code Fail Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Description Location: Old can redemption area Comments: Remove obstructions to clear path of access to fire alarm pull station. Location: Main exit sliding glass doors Comments: Remove gift card stand obstructing fire alarm pull station. GENERATED ON 12/18/25, 2:55 PM 7 OF 15 Additional Codes Status Code Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1 - General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. Description Location: Back-up generator room Comments: Secure all compressed gas cylinders (refrigerant) with chain to avoid tip over. Location: Starbucks Comments: Remove ice maker from power strip, appliance shall plug directly to wall outlet. Adding outlet requires licensed contractor obtaining permit and inspection. GENERATED ON 12/18/25, 2:55 PM 8 OF 15 Electrical Safety Status Code Fail O Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Starbucks Comments: Remove extension cord powering under mounted light, extension cords are for temporary use only. Flexible wiring shall not pass through metal fresh air cover as seen in picture. Location: Outside main walk-in freezer Comments: Replace missing cover to box. GENERATED ON 12/18/25, 2:55 PM 9 OF 15 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Exterior (west side of building) Comments: Repair or replace outlets with missing weather covers. Location: Wine & Spirits back room Comments: Remove storage within 30" in total width from panel and 36" in front of. Maintain clearances at all times. Location: Customer service electrical room Comments: Remove storage within 30" in total width from panel and 36" in front of. Maintain clearances at all times. GENERATED ON 12/18/25. 2:55 PM 10 OF 15 FF�aii 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. Commercial Cooking Hood Suppression System Status Code Fail 606.3.3.1- Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Self checkout closest to "Register 9" Comments: Power strip shall be mounted to avoid hanging by wires. Description Location: Kitchen hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 4 days past due as of 12/17125. GENERATED ON 12/18/25, 2:55 PM 11 OF 15 Fire Resistant Construction Maintenance Status Code Fail Fail 705.2 - Inspection and maintenance. Opening protectives in fire -resistance -rated assemblies shall be inspected and maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. 705.2.6 - Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Description Location: Upper level sprinkler room Comments: Replace missing ceiling tile. Location: Bakery storage Comments: Provide annual inspection of rolling fire door. Last current inspection documented 2-4-24. GENERATED ON 12/18/25, 2:55 PM 12 OF 15 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Sprinkler riser area Comments: Used fire extinguisher shall be serviced and mounted on wall bracket in required location GENERATED ON 12/18/25, 2:55 PM 13 OF 15 Fail 0 906.6 - Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Location: Employee restrooms Comments: Remove obstructions (crates) from clear unobstructed access to fire extinguisher. Maintain clearance at all times. GENERATED ON 12/18/25, 2:55 PM 14 OF 15 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $235.00 Invoice Number N/A Check Number Transaction Number NIA N/A GENERATED ON 12/18/25, 2:55 PM 15 OF 15