Loading...
HomeMy WebLinkAbout1956 LAFAYETTE STCustomer #: 3312 CORK'S GROCERY 1956 LAFAYETTE ST WATERLOO, IA 50703 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 12/16/2025 01/19/2026 2026-00000265 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1956 LAFAYETTE ST - 12-15-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Pricel $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 3312 12/16/2025 01/19/2026 2026-00000265 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Cork's Grocery - 1956 Lafayette ST, BLDG 1956 Lafayette St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 12115/2025 Inspection Type Annual Inspection (1Yr) 331zk/ 425 E. 3rd Street Inspection Number 16420 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Otherinspectors NIA SUMMARY OF INSPECTION 0 36 Passed codes NEXT STEPS 0 12 Failed codes 0 31 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 12/15/2025 @ 15:17 • $80 annual inspection fee BRAD BALDWIN - 12/16/2025 @ 08:25 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 01/0812026 BRAD BALDWIN - 12/16/2025 @ 08:25 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 12/1612025 @ 08:25 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature Shaista Yasmeen CHECKLISTS No signature Report completed post inspection Date: BRAD BALDWIN 12/16/2025 GENERATED ON 12/16/25, 8:29 AM 1 OF 11 General Housekeeping Status Code Fail 305.1 - Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Description Location: Furnace behind Pepsi fountain machine Comments: Remove storage from within 36" of furnace, maintain clearance at all times. GENERATED ON 12/16/25, 8:29 AM 2 OF 11 Additional Codes Status Code Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Description Location: Walk-in fridge Comments: Secure compressed gas cylinders with chain to avoid tip over. GENERATED ON 12/16/25, 8:29 AM 3 OF 11 Fail l�l 603.1- General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. Location: Behind counter near office. Comments: Remove microwave from power strip. Appliance shall plug directly to wall outlet. s ;A1�sP 1 f TAMPONS GENERATED ON 12/16/25, 8:29 AM 4 OF 11 Electrical Safety Status Code Fail 803.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Outlet at end of shelving near Pepsi fountain Comments: Licensed electrician shall make necessary repairs to damaged wiring. Keep receipt of work completed to show inspector. GENERATED ON 12/16/25, 8:29 AM 5 OF 11 Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Top of stairs to basement Comments: Relocate cords to avoid damage from foot traffic and being pinched in door or provide a Listed Cord Floor Protector over cords to avoid damage. Location: Basement near stairs Comments: Install cover back on junction box GENERATED ON 12/16/25, 8:29 AM 6 OF 11 Fail Fail l�J 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Basement near furnace Comments: Install knock -out plug in opening in box Location: Basement near electric panels Comments: Install missing cover on box GENERATED ON 12/16/25, 8:29 AM 7 OF 11 Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Behind counter above microwave Comments: Replace missing outlet cover Location: Office Comments: Remove extension cord concealed above drop ceiling. Extension cords approved for temporary use only. GENERATED ON 12/16/25, 8:29 AM 8 OF 11 Fire Resistant Construction Maintenance Status Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Descriptk n Location: Above Pepsi fountain machine Comments: Replace missing ceiling tiles GENERATED ON 12/16/25, 8:29 AM 9 OF 11 Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Comments: Provide annual service to fire extinguishers, currently due by January 2026. GENERATED ON 12/16/25, 8:29 AM 10 OF 11 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 12/16/25, 8:29 AM 11 OF 11