Loading...
HomeMy WebLinkAbout1608 UNIVERSITY AVEINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/14/2025 12/19/2025 2026-00000216 $100.00 Customer #: 24828 GREEN LEAF TOBACCO AND E-CIGS 1608 UNIVERSITY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-1608 UNIVERSITY AVE.,- 11/07/2025 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24828 11/14/2025 12/19/2025 2026-00000216 $100.00 Less Prepayment Total Due --+ City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Green Leaf Tobacco and E-Cigs - 1608 University AVE, BLDG 1608 UNIVERSITY AVE - STE B, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 1110712025 Lead inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr)_ REINSPECTION Other Inspectors NIA Shift NIA o7DY 425 E. 3rd Street %O , Inspection Number 18017-R1 Station Unit NIA NIA SUMMARY OF INSPECTION 00 01 010 Passed codes NEXT STEPS Resolved violations Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 10/09/2025 @ 14:53 $80 annual inspection fee BRAD BALDWIN - 10/09/2025 @ 14:53 Fire extinguishers due annually serviced in September 2026 BRAD BALDWIN - 10/09/2025 @ 14:53 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224 BRAD BALDWIN - 10/09/2025 @ 14:53 Reinspection Date 12/05/2025 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 1110712025 @ 14:41 $100 re -inspection fee, failure to make progress on correcting violations. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection MO 2025 Date: BRAD BALDWIN 11107/2025 CHECKLISTS GENERATED ON 11/7/25, 2.44 PM 1 OF 7 Additional Codes Status Code Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Description Location: Back exit Comments: Per occupancy, 2nd exit not required. Would be approved to remove exit sign or properly cover. Removal requires electric capped and contained in box with cover. Failure to cover or remove sign requires removal of interior door obstructing view of exit and removal of all obstructions to clear access of exit. GENERATED ON 11/7/25, 2:44 PM 2 OF 7 Reinspection Status Code Description Fail 315.3.3 - Equipment rooms. 0 Combustible material shall not be stored in boiler rooms, Location: Mechanical room mechanical rooms, electrical equipment rooms or in fire Comments: Remove storage from mechanical room, maintain proper command centers as specified in Section 508.1.5. Fail 603.1 - General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. clearance at all times. Additional comments: More storage noted today than last visit. Location: Near electric panel Comments: Remove microwave from power strip, appliance shall be plugged directly to wall outlet. GENERATED ON 11/7/25, 2:44 PM 3 OF 7 Fail Fail 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures AU electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Location: Window lighting Comments: Provide documentation of proper listing of light fixtures. Noted "CE" listing as shown in picture not approved for use. Location: Mechanical room Comments: Remove cube type multi -plug adapter. May replace with properly mounted power strip with manual reset plugged directly to wall outlet for light duty electric only. GENERATED ON 11/7/25, 2:44 PM 4 OF 7 Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Bathroom Comments: Remove flexible cord to power strip from penetrating wall. Location: Under register counter Comments: Black multi -plug cord not permitted for permanent use. Would approve to replace with properly mounted power strip with manual reset for light duty electric only. GENERATED ON 11/7/25, 2:44 PM 5 OF 7 Fail Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Glass display cabinets Comments: Remove flexible cord concealed under cabinets running across walkway IMMEDIATELY. Staff member grabbed cord during inspection when cord pulled apart from previous damage Location: Register POS system Comments: Flexible multi -plug cord used for POS system not permitted for permanent use. Relocate system to plug to wall outlet or provide new outlet by licensed electrical contractor by obtaining permit and inspection. Would approve properly mounted power strip with manual reset for light duty electric only. Location: Mechanical room Comments: Remove tv cord from white extension cord. Would approve IV plugged to properly mounted power strip with manual reset plugged directly to wall outlet. GENERATED ON 11/7/25, 2:44 PM 6 OF 7 Statement of Fees FEE Invoice Date inspection Fee NIA $100.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 11/7/25, 2:44 PM 7 OF 7