COMMERCIAL FIRE INSPECTION-1916 E. MITCHELL AVE-
11/20/2025
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 20,000
OCCUPANCY FEE
Total Price
$90.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24621
11/24/2025
12/29/2025
2026-00000237
$100.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report a�
4a
p 425 E. 3rd Street
Lolo Food Market - 1916 E Mitchell AVE, BLDG 1916 E Mitchell Ave, Waterloo IA
50702
INSPECTION DETAILS
Inspection Date
11/20/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Complaint l REINSPECTION
Other Inspectors
NIA
vw 00
Inspection Number
17660-R2
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
0 0 0 3
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 1011512025 @ 15:13
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
12/1912025
BRAD BALDWIN - 10/15/2025 @ 15:13
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 10115/2025 @ 15:13
Corrected during 10/15125 inspection: Removed power strip daisy chained behind check-out counter.
BRAD BALDWIN - 10115/2025 @ 15:13
All appliances manufactured to be plugged directly to wall receptacles shall be installed and maintained properly.
BRAD BALDWIN -11/20/2025 @ 13:32
$100 re -inspection fee, failure to complete corrections.
SIGNATURES
Contact signature Inspector signature
Yves Pierre-louis
CHECKLISTS
No signature
Report completed post inspection
Date: BRAD BALDWIN 11120/2025
GENERATED ON 11/20/25, 1:35 PM 1 OF 4
Additional Codes
Code
Fail
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
Description
Location: Behind register stand
Comments: Remove power strip plugged to another power strip as
seen in picture attached. Power strips shall be plugged directly to
wall outlets at all times for light duty electric only.
GENERATED ON 11/20/25, 1:35 PM
2 OF 4
Reinspection
Status Code
Fail
Fail
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Description
Location: Checkout stand
Comments: Power strip cord running across walkway shall be
relocated to avoid damage of foot traffic or provide UL Listed cord
floor protector.
Additional comments: No progress made today 11/20125
Location: Behind register counter
Comments: Remove white multi -plug extension cord from power
strip.