Loading...
HomeMy WebLinkAbout1825 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/24/2025 12/29/2025 2026-00000231 $100.00 Customer #: 24261 BOARDERS INN AND SUITES 1825 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-1825 LA PORTE RD-11/19/2025 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE CUSTOMER # 24261 Total Price $90.00 $10.00 BILLING DATE 11/24/2025 DUE DATE 12/29/2025 INVOICE # 2026-00000231 CHARGES Less Prepayment Total Due —> City of Waterloo $100.00 $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Boarders Inn & Suites -1825 La Porte RD, BLDG 1825 La Porte Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11/19/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street 4100 it Inspection Number 16713 Shift Station Unit N/A NIA NIA SUMMARY OF INSPECTION 040 G4 ®29 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 11/19/2025 @ 15:52 Clothes dryers last cleaned by J. Patel in house on 1/27/2025. JEREMIAH VANDYKE - 11/19/2025 @ 15:53 1120/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE - 11/19/2025 @ 15:53 Fire extinguishers serviced by July 2025. Reinspection Date 12/19/2025 JEREMIAH VANDYKE - 11/19/2025 @ 16:07 PERMIT INFO: • Any construction, electrical, plumbing, life safety, and HVAC requires proper permit and inspections. • All electrical work and repair must be completed by a licensed electrical contractor with permits and inspections. JEREMIAH VANDYKE - 11/19/2025 @ 16:07 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 11/19/2025 @ 16:07 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 11/19/2025 @ 16:08 Inspection Fee = $100.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature GENERATED ON 11/19/25, 4:08 PM 1 OF 4 No signature Report completed post inspection Vishal Patel CHECKLISTS General Housekeeping Date: Fail 315.3.2 - Means of egress. Combustible materials shall not be stored in exits or enclosures for stairways and ramps. Combustible materials in the means of egress during construction, demolition, remodeling or alterations shall comply with Section 3312.3. Documentation Cole Fail 404.2.2 - Fire safety plans. Fire safety plans shall include the following: 1.The procedure for reporting a fire or other emergency. 2.The life safety strategy including the following: 2.1.Procedures for notifying occupants, including areas with a private mode alarm system. 2.2.Procedures for occupants under a defend -in -place response. 2.3.Procedures for evacuating occupants, including those who need evacuation assistance. 3.Site plans indicating the following: 3.1.The occupancy assembly point. 3.2.The locations of fire hydrants. 3.3.The normal routes of fire department vehicle access. 4.Floor plans identifying the locations of the following: 4.1. Exits. 4.2.Primary evacuation routes. 4.3.Secondary evacuation routes. 4.4.Accessible egress routes. 4.4.1.Areas of refuge. 4.4.2.Exterior areas for assisted rescue. 4.5.Refuge areas associated with smoke barriers and horizontal exits. 4.6.Manual fire alarm boxes. 4.7.Portabie fire extinguishers. 4.8.Occupant-use hose stations. 4.9.Fire alarm annunciators and controls. 5.A list of major fire hazards associated with the normal use and occupancy of the premises, including maintenance and housekeeping procedures. 6.Identification and assignment of personnel responsible for maintenance of systems and equipment installed to prevent or control fires. 7.Identification and assignment of personnel responsible for maintenance, housekeeping and controlling fuel hazard sources. Electrical Safety Code Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Description Location: 1st floor bottom of both stairways. Comments: Need to remove all storage from stairways on east and west side. Description Location: Need to check all rooms. Comments: Some guest doors have paper only escape plans on inside door. Need to check and replace with hard copy or laminated copy of escape plans that are secured door and will not be ripped off. Description Location: All guest rooms with powerstrips or muitiplug adapter. Comments: Fridge, microwave, and coffee maker need to be plugged directly into wall outlets, not into power strip or multiplug adapter. IF NEW OUTLETS ARE NEEDED, a licensed electrician with permit needs to be done. GENERATED ON 11/19/25. 4:08 PM 2 OF 4 Fire Resistant Construction Maintenance St!tu Code Fail 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Oescripticn Location: 1. Hallway door near room 117. 2. Hallway door near 207. Comments: Marked fire doors need to close and latch properly. If a door is replaced a building permit will need to be pulled at the City. GENERATED ON 11/19/25, 4:08 PM 3 OF 4 v E0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 11/19/25, 4:08 PM 4 OF 4