Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4025 HAMMOND AVE
Customer #: 7011 COUNTRY INN & SUITES 4025 HAMMOND AVE WATERLOO, IA 50702 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/24/2025 12/29/2025 2026-00000228 $100.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-4025 HAMMOND AVE- 11/18/2025 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 7011 11/24/2025 12/29/2025 2026-00000228 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Country Inn & Suites - 4025 Hammond AVE, BLDG 4025 Hammond Ave, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 11/18/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) Other inspectors NIA Shift NIA SUMMARY OF INSPECTION 046 09 ®20 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 11/18/2025 @ 15:24 Fire extinguisher serviced by Pro Shield Jan 2025. JEREMIAH VANDYKE - 11/18/2025 @ 15:25 11/3/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed JEREMIAH VANDYKE - 11/18/2025 @ 15:25 StWion NIA 9/2/2025 S - Private Fire Hydrants BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 11/18/2025 @ 15:25 79// 425 E. 3rd Street $Io},o© Inspection Number 15852 Unit NIA Reinspection Date 12118/2025 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. ****"Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 11/18/2025 @ 15:25 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 11/1812025 @ 15:25 Inspection Fee = $100.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 11/18/25, 3:39 PM 1 OF 4 Jessica Porter CHECKLISTS Means of Egress Code Date: Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Emergency Equipment _tale_ Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Additional Codes .`:.:..._ Code Fail Fail 1103.8 - Single- and multiple -station smoke alarms. Single- and multiple -station smoke alarms shall be installed in existing Group 1-1 and R occupancies in accordance with Sections 1103.8.1 through 1103.8.3. 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. /7) Description Location: Pool area. Comments: North marked exit door was hard to open. Need to repair or replace. Description Location: Pool area. Comments: Tested 3 egress lights and need to repair or replace. Location: 1. Near elevator on 1st floor the lower floor exit light. 2. 2 exit lights in pool area. Comments: Tested exit lights, need to repair or replace. Description Location: Rooms 219, 115, 116, 119, and 217. Comments: Need to repair or replace smoke alarms. Discussed with Front office manager to talk with house keeping on checking smoke alarms. Location: Guest and Hotel's clothes dryers. Comments: Need to maintain cleaning behind dryers. Clothes Dryer Exhaust Duct system must be cleaned from the dryer to the outside DOCUMENTED by who and when serviced. Last serviced by Harris Cleaning on 12-4-2025. Need to schedule cleaning. GENERATED ON 11/18/25, 3:39 PM 2 OF 4 General Housekeeping cm-Ltd,Code Fail 315.3.3 - Equipment rooms. Combustible material shall not be stored in boiler rooms, mechanical rooms, electrical equipment rooms or in fire command centers as specified in Section 508.1.5. Fire Sprinkler System Fail Code 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Electrical Safety states code Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fire Resistant Construction Maintenance Fail Code 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Sprinkler riser room/ main electrical room. Comments: Need to clear out storage. Description Location: 1. North stairway 2nd floor landing. 2. Room 102. Comments: Contact sprinkler contractor to repair missing eschutcheons. Description Location: 1. Kitchen outlet by fridge. 2. Food serving area outlet. 3. Near office area. Comments: All 3 outlets show arcing. Must contact licensed electrician to address outlets. These outlets are out of service until repaired. Description Location: Sprinkler riser room/Main electrical on 1st floor. Comments: Hole in ceiling needs repaired near elevator room. A BUILDING PERMIT and inspection will be required due to hole in fire wall. GENERATED ON 11/18/25, 3:39 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 11/18/25, 3:39 PM 4 OF 4