HomeMy WebLinkAbout3052 MARNIE AVEINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
11/24/2025
12/29/2025
2026-00000227
$100.00
Customer #: 23029
HOWARD JOHSON
3052 MARNIE AVE
WATERLOO, IA 50702
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION-3052 MARNIE AVE-11/18/2025
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 20,000
OCCUPANCY FEE
Total Price
$90.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
23029
11/24/2025
12/29/2025
2026-00000227
$100.00
Less Prepayment
Total Due -->
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Howard Johnson - 3052 Marnie AVE, BLDG 3052 Marnie Ave, Waterloo IA 50701
INSPECTION DETAILS
Inspection Date
11/18/2025
Lead lnspector
JEREMIAH VANDYKE
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
N/A
d3D,Riy
425 E. 3rd Street
4 rto iCtD
Inspection Number
16352
Shift Station Unit
NIA NIA N/A
SUMMARY OF INSPECTION
0 44
Passed codes
NEXT STEPS
0 8
Failed codes
23
NIA codes
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE - 11/18/2025 @ 14:41
Reinspection Date
12/18/2025
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday - Friday, 8:00 a m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed
the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees
may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 11/18/2025 @ 14:41
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 11/18/2025 @ 14:41
Inspection Fee = $100.00 (To be mailed out by City via snail mail.)
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Arp Patel
CHECKLISTS
Date: JEREMIAH VANDYKE
11/18/2025
GENERATED ON 11/18/25, 2:43 PM
1 OF 5
Additional Codes
Status Code
Fail 1103.8 - Single- and multiple -station smoke alarms.
Single- and multiple -station smoke alarms shall be installed
in existing Group 1-1 and R occupancies in accordance with
Sections 1103.8.1 through 1103.8.3.
Fail
610.1.2 - Maintenance.
The lint trap, mechanical and heating components, and the
exhaust duct system of a clothes dryer shall be maintained in
accordance with the manufacturer's operating
instructions to prevent the accumulation of lint or debris that
prevents the exhaust of air and products of combustion.
Fire Alarm System
v..,_u_ Code
Fail Chapter 14 - Inspection, testing, and maintenance
Fire alarm system tested at least annually by licensed
contractor
Description
Location: Rooms: 102, 104, 122, 128, 214 x2, 216, 219, 220, 229, 231,
233.
Comments: Smoke alarms were tested and failed or missing. Need to
repair or replace.
Location: Clothes Dryer Exhaust Duct system must be cleaned from
the dryer to the outside DOCUMENTED by who and when serviced
Comments: Clothes Dryer Exhaust Duct system must be cleaned
from the dryer to the outside DOCUMENTED by who and when
serviced
Description
Location: Fire alarm is past due 42 days.
Comments: Contact fire alarm contractor to inspect and upload to
compliance engine.
GENERATED ON 11/18/25, 2:43 PM 2 OF 5
Electrical Safety
status Code
Fail
Fail
Fail
Fail
603.4 - Working space and clearancesclearance.
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
603.5.2 - Application and usePower supply.
Relocatable power taps and current taps shall be directly
connected to a permanently installed receptacle. Exceptions:
1. Where approved for use in a Group A occupancy or in a
meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected
together or connected to an extension cord for temporary use
to supply power to electronic equipment. 2. Current taps and
relocatable power taps shall not be required to connect
directly to a permanently installed receptacle outlet where
used for 90 days or less for the purpose of testing the
performance of such devices.
603.8 - Temporary wiring.
Temporary The use of temporary wiring for electrical power
and lighting installations shall not exceed is allowed for a
period not to exceed of 90 days. Temporary wiring methods
shall meet the applicable provisions of NFPA 70. Exception:
Temporary wiring for electrical power and lighting
installations is allowed complying with the applicable
provisions of NFPA 70 is permitted during periods of
construction, remodeling, repair or demolition of buildings,
structures, equipment or similar activities.
Description
Location: 1st floor mechanical room.
Comments: Need to clear 3 feet in front of electrical panels and clear
our storage.
Location: Check ALL rooms. Rooms I found: #116. 122, 124, 126,127,
128, 129, 206, 207, 209, 211, 218, 219, 220, 224, 226, 227, 228, 229, 231,
232.
Comments: Multiple rooms had either the coffee maker, microwave,
or fridge plugged into power strip. Coffee maker, microwave, and
fridge MUST be plugged directly into wall outlet. Some outlets are not
working correctly. Arp advise Tracey to check all rooms and write
down which outlets were not working for maintenance.
Location: Check ALL rooms.
Comments: Multiple power strips were hanging by cords and need to
be secured to TV stand.
Location: Patio back area with Christmas lights.
Comments: Christmas lights are only allowed for 90 days. Please
remove. If wanting lighting on patio the lights will need to be
commercial grade UL listing for year around use. Please provide
paperwork.
GENERATED ON 11/18/25, 2:43 PM 3 OF 5
Portable Fire Extingusihers
Status Cote
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group I-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Description:
Location: Fire extinguishers are past due.
Comments: Contact fire extinguisher contractor to inspect and re tag.
GENERATED ON 11/18/25, 2:43 PM
4 OF 5
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $100.00
Invoice Number
NIA
Check Number Transaction Number
NIA NIA
GENERATED ON 11/18/25, 2:43 PM
5 OF 5