Loading...
HomeMy WebLinkAbout2343 LOGAN AVECustomer #: 6265 MOTEL 6 2343 LOGAN AV WATERLOO, IA 50703 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/24/2025 12/29/2025 2026-00000224 $100.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-2343 LOGAN AVE-11/17/2025 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 6265 11/24/2025 12/29/2025 2026-00000224 $100.00 Less Prepayment Total Due — City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Motel 6 - 2343 Logan AVE, BLDG 2343 Logan Ave, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 11/17/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street co, Inspection Number 15597 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 039 Passed codes NEXT STEPS 8 Failed codes 28 NIA codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 11/17/2025 @ 11:16 11/3/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Deficient JEREMIAH VANDYKE - 11/17/2025 @ 11:16 1/3/2025 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 11/17/2025 @ 11:17 Reinspection Date 12/17/2025 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection.'**** Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 11/17/2025 @ 11:17 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 11/17/2025 @ 11:17 Inspection Fee = $100.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 11/17/25, 11:20 AM 1 OF 6 Arp Patel Date: CHECKLISTS Emergency Equipment Status Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Additional Codes Status Code Fail Fail l:J 1103.8 - Single- and multiple -station smoke alarms. Single- and multiple -station smoke alarms shall be installed in existing Group 1-1 and R occupancies in accordance with Sections 1103.8.1 through 1103.8.3. 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Fire Alarm System Status Code Fail Chapter 14 - Inspection, testing, and maintenance Fire alarm system tested at least annually by licensed contractor Description Location: Pool area. Comments: ExitlEgress light above south door tested and failed. Need to replace or repair. Description Location: Rooms # 114, 206, 214, 217, 218, 223. Comments: Smoke alarms were tested and failed or missing. Need to repair or replace. Location: Hotel guest clothes dryers and hotel's large dryer. Comments: Clothes Dryer Exhaust Duct system must be cleaned from the dryer to the outside DOCUMENTED by who and when serviced. Description Location: Deficiency on Compliance engine needs addressed and updated by contractor. Contact fire alarm contractor to address deficiency as soon as possible. Comments: Deficiency Found: Answer: Fire alarm has a sprinkler system that is not monitored GENERATED ON 11/17/25, 11:20 AM 2 OF 6 Electrical Safety Status Code Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Description Location: 103 behind bed. Comments: Green Extension cord plugged into power strip. Can not daisy chain. GENERATED ON 11/17/25, 11:20 AM 3 OF 6 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Fire Resistant Construction Maintenance ..,atus Fail Code 705.2 - Inspection and maintenance. Opening protectives in fire -resistance -rated assemblies shall be inspected and maintained in accordance with NFPA 80. Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105. Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked, obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Opening protectives and smoke and draft control doors shall not be modified. Location: 103 Behind bed. Comments: Can not use green extension cord as permenant wiring. D St,'i;pTtOn Location: 1st floor and 2nd floor north hallway doors to steps and middle hallways both levels had door stops holding marked fire doors open. Discussed getting mag locks installed by fire alarm contractor. Comments: 1st floor and 2nd floor north hallway doors to steps and middle hallways both levels had door stops holding marked fire doors open. Discussed getting mag locks installed by fire alarm contractor. GENERATED ON 11/17/25, 11:20 AM 4 OF 6 Portable Fire Extingusihers Status Cede Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Fire extinguishers are past due and need to be inspected by licensed extinguisher contractor and re tagged. Comments: Fire extinguishers are past due and need to be inspected by licensed extinguisher contractor and re tagged. GENERATED ON 11/17/25, 11:20 AM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Invoice Number N/A Check Number Transaction Number NIA N/A GENERATED ON 11/17/25, 11:20 AM 6 OF 6