Loading...
HomeMy WebLinkAbout213 E 5TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 11/24/2025 12/29/2025 2026-00000223 $80.00 Customer #: 23164 THE COMFORT ZONE 213 E 5TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-213 E. 5TH STREET-11/21/2025 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23164 11/24/2025 12/29/2025 2026-00000223 $80.00 Less Prepayment Total Due -* City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report The Comfort Zone - 213 E 5th ST, BLDG 213 - 219 E 5th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 11/21/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street -tom Inspection Number 15868 Shift Station Unit N/A NIA NIA SUMMARY OF INSPECTION 046 03 024 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 11/21/2025 @ 14:55 8/19/2025 S - (Annual) Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE - 11/21/2025 @ 14:55 3/1812025 S - (Annual) Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE - 11/2112025 @ 14:56 Reinspection Date 12121/2025 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 11/2112025 @ 14:56 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 11/21/2025 @ 14:57 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature Tommy Mccelllan-bey No signature Report completed post inspection Date: JEREMIAH VANDYKE 11/21/2025 GENERATED ON 11/21/25, 3:00 PM 1 OF 3 CHECKLISTS Commercial Cooking Hood Suppression System Status Code Fail Fail 606.3.3 - Cleaning. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. 904.13.5.2 - Extinguishing system service. Automatic fire -extinguishing systems shall be serviced not less frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Portable Fire Extingusihers Status Fail Cede 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Need hood cleaning completed. Comments: AKA is scheduled 11123 for the hood cleaning. Please have contractor upload report to Compliance engine as soon as possible. Location: Hood suppression needs inspected by licesned contractor. Comments: Owner is contacting Superior to get hood serviced. Hood suppression report needs to be uploaded to Compliance engine as soon as possible by contractor. Description Location: All extinguishers are past due (including Class K), need to be inspected and retagged. Comments: All extinguishers are past due (including Class K), need to be inspected and retagged. Owner states they will contact Superior Fire. GENERATED ON 11/21/25, 3:00 PM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 11/21/25, 3:00 PM 3 OF 3