Loading...
HomeMy WebLinkAbout1410 FLAMMANG DRINVOICE DATE DUE DATE ' INVOICE # TOTAL DUE 09/05/2025 10/15/2025 2026-00000105 $80.00 Customer #: 15097 HARDEE'S 1505736 10777 Barkley St LEAWOOD, KS 66211 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1410 FLAMMANG DR - 8-26-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 15097 09/05/2025 10/15/2025 2026-00000105 $80.00 Less Prepayment Total Due -> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Hardee's - 1410 Flammang DR, BLDG 1410 Flammang Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 08/26/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) c1i Other Inspectors NIA 425 E. 3rd Street Inspection Number 1096 Shift Station Unit NIA NIA NIA SUMMARY OF INSPECTION 0 46 GO 9 Passed codes Failed codes NEXT STEPS 23 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/26/2025 @ 12:45 $80 annual inspection fee BRAD BALDWIN - 08/26/2025 @ 12:48 Kitchen hood suppression system due for service on 9/23/25. BRAD BALDWIN - 08/26/2025 @ 13:13 Fire extinguishers due annually serviced March 2026. BRAD BALDWIN - 08/26/2025 @ 13:35 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 08/2612025 @ 13:35 Reinspection Date 09/18/2025 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Eic John Kelchen (2025) Regional Date: BRAD BALDWIN 08/26/2025 CHECKLISTS GENERATED ON 8/26/25, 1:37 PM 1 OF 6 Additional Codes Status Code Description Fail 102.4 - Application of building code. 0 The design and construction of new structures shall comply Location: Water heater installation with the International Building Code ,and any alterations, Comments: Obtain plumbing permit and inspection of water heater additions, changes in use or changes in structures required installed without permit by Heartland Gaskets. by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. AUTOMATIC STORAGE WATER NEATER VENT INSTALLATR)k 3T fi"f CSAIANSI Z.t1.Vp,11CSA 4,1-2011 bNv an9 L99341132 INA 90 _ • IS Location: Hood exhaust control panel 12111929921 Comments: Relocate shelf to avoid obstructing access to panel, maintain clear path. GENERATED ON 8/26/25, 1:37 PM 2 OF 6 Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 606.3.1 - Ventilation system. The ventilation system in connection with hoods shall be operated at the required rate of air movement, and grease filters listed and labeled in accordance with UL 1046 shall be in place where equipment under a kitchen grease hood is used. Location: CO2 storage Comments: Secure compressed gas cylinder with chain to avoid tip over. Location: Kitchen flat top hood filters Comments: Close gaps in grease filters. Filters not in place cause more grease in ductwork and on cables for fire supression. GENERATED ON 8/26/25, 1:37 PM 3 OF 6 General Housekeeping Sta[uua cod, Fail Fail l_J 304.3.1- Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. 305.1 - Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Fire Service Features Status Code Fail 505.1 - Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Location: Water heater Comments: Remove and maintain clearance within 36 " from water heater D Comments: Provide address identification numbers in contrast with building. GENERATED ON 8/26/25, 1:37 PM 4 OF 6 Fire Resistant Construction Maintenance Status Code Fail l^J Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Office Comments: Replace missing ceiling tile. Location: Front vestibule Comments: Replace missing ceiling tile. GENERATED ON 8/26/25, 1:37 PM 5 OF 6 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA WA GENERATED ON 8/26/25, 1:37 PM 6 OF 6