Loading...
HomeMy WebLinkAbout2034 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/05/2025 10/15/2025 2026-00000104 $200.00 Customer #: 12855 HAMPTON INN 2034 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2034 LA PORTE RD - 8-22-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION 3 Total Price $200.00 CUSTOMER # 12855 BILLING DATE 09/05/2025 DUE DATE 10/15/2025 INVOICE # 2026-00000104 CHARGES $200.00 Less Prepayment Total Due —> City of Waterloo $0.00 $200.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Hampton Inn & Suites - 2034 La Porte RD, BLDG 2034 La Porte Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 08/2212025 Lead Inspector BRAD BALDWIN Other Inspectors NIA Inspection Type Annual Inspection (1Yr) REINSPECTION 425 E. 3rd Street Inspection Number 13671-R8 N/A Station N/A Unit NIA SUMMARY OF INSPECTION o Passed codes NEXT STEPS 9 2 Resolved violations ®11 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/25/2025 @ 07:58 $200 re -inspection tee, failure to correct deficiencies as of 8/22/25. BRAD BALDWIN - 07123/2025 @ 07:32 $200 Re -inspection tee for failure to correct violations on 6/23/25 BRAD BALDWIN - 07/23/2025 @ 07:32 Provide corrections to avoid re -inspection fees BRAD BALDWIN - 07123/2025 @ 07:32 Annual inspection $235 BRAD BALDWIN - 07/23/2025 @ 07:32 Provide corrections to avoid re -inspection fees. BRAD BALDWIN - 07/23/2025 @ 07:32 Re -inspection fee $100 BRAD BALDWIN - 07/23/2025 @ 07:32 Corrections not made on fire sprinkler, standpipe, or fire alarm and no date for completion of fire door certifications. BRAD BALDWIN - 07/2312025 @ 07:32 Re -inspection fee $150 BRAD BALDWIN - 07/2312025 @ 07:32 Called Mitch on 4/17/25 and he stated no improvement. BRAD BALDWIN - 07/23/2025 @ 07:32 Re -inspection fee $200 Reinspectlon Date 09/19/2025 GENERATED ON 8/25/25, 8:04 AM 1 OF 8 BRAD BALDWIN - 0712312025 @ 07:32 annual inspection $200 BRAD BALDWIN - 07123/2025 @ 07:32 We are recommending denial of alcohol license to the City Council because of lack of progress on required certification of guest room fire doors that were altered during construction. BRAD BALDWIN - 07/23/2025 @ 07:32 $200 Re -inspection fee, failure to complete corrections as of 7122125 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Cayenne Adams - Manager CHECKLISTS EE Date: BRAD BALDWIN 0812512025 GENERATED ON 8/25/25, 8:04 AM 2 OF 8 Reinspection status Code Fail 0 Fail 0 Fail 0 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 5.2.1 - Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7,Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Deserintlo Location: Entire buiding Comments: Obtain permits and inspections for all work concerning fire door repair, replacement smoke seals, all hardware replaced. Please see original attached email with codes concerning information requiered for fire door hardware. Please contact Building Official Greg Ahlhelm with questions. 319-291-4319 Location: Annual Standpipe insepction deficiencies Comments: Provide current annual fire sprinkler stand pipe inspection report wth all discrepancies corrected. Current report lists 2 discrepancies. Contractor must upload corrections online to the compliance engine. Location: Entire second floor guest fire doors Comments: Install approved smoke seal in all fire door openings that has been removed including stair doors and utility areas. Check all other floors GENERATED ON 8/25/25. 8:04 AM 3 OF 8 Fail 704.1 - Maintaining protection. Where required when the budding was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorfceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: 1st floor outside of elevators Comments: Repair ceiling with sheetrock, mud and tape. Staff did indicate more ceiling will need removed to complete leak on sprinkler pipe. Repair will require a permit and inspection. GENERATED ON 8/25/25, 8:04 AM 4 OF 8 Fail Fail l�J 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer&4039;s installation instructions. Location: Entire Second Floor Comments: verify all removed smoke seals have been replaced on second floor. Also 4th floor and all other smoke sweeps added to bottom of doors must be verified as listed for fire doors and inspected. 704.1 - Maintaining protection. Where required when the building was originally constructed, Location: obtain permit and inspections materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 8/25/25, 8:04 AM 5 OF 8 Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. &Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Entire 4th Floor Fire Doors Comments: Repair or replace fire doors that are improperly installed. Doors must seal all sides including top and botom to prevent smoke/fire from infiltrating fire rated coridoor. GENERATED ON 8/25/25, 8:04 AM 6 OF 8 Fail Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer&#O39;s installation instructions. 705.2.4 - Door operation. Swinging fire doors shall close from the full -open position and latch automatically. Fail Chapter 14 - Inspection, testing, and maintenance 0 Fire alarm system tested at least annually by licensed contractor Location: Stairway Fire Door by room 330 Comments: Repair fire door. There is a gap at bottom of door. Must completely seal Location: Guest Computer Room Comments: patch sheetrock ceiling with sheetrock. Mud and tape joints. Location: 2nd Floor laundry inside door Comments: Repair fire door. Fire door must completely self -close and latch. Upper part of door does not properly seal. Location: Annual Fire Alarm Inspection Comments: Provide current semi-annual fire alarm inspection report with all discrepancies corrected. Currently 106 days past due. Contractor must upload online to the compliance engine. GENERATED ON 8/25/25, 8:04 AM 7 OF 8 Statement of Fees FEE Invoice Date Inspection Fee NIA $200.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 8/25/25, 8:04 AM 8 OF 8