Loading...
HomeMy WebLinkAbout441 TOWER PARK DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/05/2025 10/15/2025 2026-00000099 $100.00 Customer #: 21369 CHILITO'S 441 E TOWER PARK DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 441 TOWER PARK DR - 8-29-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # 21369 09/05/2025 10/15/2025 2026-00000099 CHARGES $100.00 Less Prepayment Total Due — City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Chilitos Mexican Bar - 441 E Tower Park DR, BLDG 441 E Tower Park Dr, Waterloo IA 50702 INSPECTION DETAILS 425 E. 3rd Street inspection Date Inspection Type Inspection Number 08/29/2025 Annual Inspection (1Yr) REINSPECTION) 14601-R2 Lead Inspector BRAD BALDWIN Other Inspectors NIA NIA Station Unit NIA NIA SUMMARY OF INSPECTION 0 0 Passed codes NEXT STEPS 0 5 Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/02/2025 @ 07:38 $100 re -inspection fee, failure to correct violations. BRAD BALDWIN - 08108/2025 @ 13:35 $80 annual inspection fee BRAD BALDWIN - 08/08/2025 @ 13:35 Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 BRAD BALDWIN - 08/08/2025 @ 13:35 Reinspection Date 09/23/2025 Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/08/2025 @ 13:35 If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Aurora Torres Date: BRAD BALDWIN 09/02/2025 CHECKLISTS GENERATED ON 9/2/25, 7:40 AM 1 OF 4 Reinspection Status Code Fail Fail Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5.3 - Installation. Relocatable power tap cords shall not extend through walls, ceilings, floors, under doors or floor coverings, or be subject to environmental or physical damage. 904.13.5.2 - Extinguishing system service. Automatic fire -extinguishing systems shall be serviced not less frequently than every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. Description Location: Food prep area Comments: Secure compressed gas cylinders with chain to avoid tip over. Additional comments: Chain tanks to wall to avoid tip -over Location: Behind hostess stand Comments: Remove multi -plug extension cord to table pager devices. Devices shall be plugged to wall outlet or power strip with manual reset plugged to wall outlet. Additional comments: Licensed electrical contractor must obtain permit and inspection. Outlet installed without permit. Location: Kitchen above beer fridge & chips station Comments: Properly mount power strip to wall or solid surface or support on shelf. Additional comments: Licensed electrical contractor must obtain permit and inspection. Outlet installed without permit. Location: Six burner range Comments: Move range to be 6 inches inside of outer edge of hood exhaust system. GENERATED ON 9/2/25, 7:40 AM 2 OF 4 Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Near main entrance Comments: Install properly serviced fire extinguisher on wall bracket no less than 4" from floor and no more than 5 ft from floor in height near front entry. GENERATED ON 9/2/25, 7:40 AM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee NIA $100.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 9/2/25, 7:40 AM 4 OF 4