COMMERCIAL INSPECTION - 441 TOWER PARK DR - 8-29-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 1
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
21369
09/05/2025
10/15/2025
2026-00000099
CHARGES
$100.00
Less Prepayment
Total Due —
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Chilitos Mexican Bar - 441 E Tower Park DR, BLDG 441 E Tower Park Dr, Waterloo IA
50702
INSPECTION DETAILS
425 E. 3rd Street
inspection Date Inspection Type Inspection Number
08/29/2025 Annual Inspection (1Yr) REINSPECTION) 14601-R2
Lead Inspector
BRAD BALDWIN
Other Inspectors
NIA
NIA
Station Unit
NIA NIA
SUMMARY OF INSPECTION
0 0
Passed codes
NEXT STEPS
0 5
Failed codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 09/02/2025 @ 07:38
$100 re -inspection fee, failure to correct violations.
BRAD BALDWIN - 08108/2025 @ 13:35
$80 annual inspection fee
BRAD BALDWIN - 08/08/2025 @ 13:35
Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 08/08/2025 @ 13:35
Reinspection Date
09/23/2025
Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 08/08/2025 @ 13:35
If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections
& re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees
start at $100, then $150, and $200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Aurora Torres Date: BRAD BALDWIN 09/02/2025
CHECKLISTS
GENERATED ON 9/2/25, 7:40 AM 1 OF 4
Reinspection
Status Code
Fail
Fail
Fail
Fail
5303.5.3 - Securing compressed gas containers, cylinders
and tanks.
Compressed gas containers, cylinders and tanks shall be
secured to prevent falling caused by contact, vibration or
seismic activity. Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object
with one or more restraints. 2.Securing containers, cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers, cylinders or tanks.
3. Nesting of compressed gas containers, cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public. Nesting shall be allowed
provided that the nested containers, cylinders or tanks, if
dislodged, do not obstruct the required means of egress.
4.Securing of compressed gas containers, cylinders and
tanks to or within a rack, framework, cabinet or similar
assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of
examination, filling, transport or servicing.
603.5 - Relocatable power taps and current taps.Multiplug
adapters.
Multiplug adapters, such as cube adapters, unfused plug
strips or any other device not complying with NFPA 70 shall
be prohibited. The construction and use of current taps and
relocatable taps shall be in accordance with NFPA 70 and this
code.
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
904.13.5.2 - Extinguishing system service.
Automatic fire -extinguishing systems shall be serviced not
less frequently than every six months and after activation of
the system. Inspection shall be by qualified individuals, and a
certificate of inspection shall be forwarded to the fire code
official upon completion.
Description
Location: Food prep area
Comments: Secure compressed gas cylinders with chain to avoid tip
over.
Additional comments: Chain tanks to wall to avoid tip -over
Location: Behind hostess stand
Comments: Remove multi -plug extension cord to table pager
devices. Devices shall be plugged to wall outlet or power strip with
manual reset plugged to wall outlet.
Additional comments: Licensed electrical contractor must obtain
permit and inspection. Outlet installed without permit.
Location: Kitchen above beer fridge & chips station
Comments: Properly mount power strip to wall or solid surface or
support on shelf.
Additional comments: Licensed electrical contractor must obtain
permit and inspection. Outlet installed without permit.
Location: Six burner range
Comments: Move range to be 6 inches inside of outer edge of hood
exhaust system.
GENERATED ON 9/2/25, 7:40 AM 2 OF 4
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Location: Near main entrance
Comments: Install properly serviced fire extinguisher on wall bracket
no less than 4" from floor and no more than 5 ft from floor in height
near front entry.