Loading...
HomeMy WebLinkAbout900 LA PORTE RDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/05/2025 10/15/2025 2026-00000098 $80.00 Customer #: 13176 CHAPALA 900 LA PORTE RD WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 900 LA PORTE RD - 8-25-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13176 09/05/2025 10/15/2025 2026-00000098 $80.00 Less Prepayment Total Due -� City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Chapalas - 900 La Porte RD, BLDG 900 La Porte Rd, Waterloo IA 50702 INSPECTION DETAILS Inspection I:)w' 08125/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA Shift Station NIA NIA 425 E. 3rd Street Inspection Number 14845 Unit N/A SUMMARY OF INSPECTION �. 55 Passed codes NEXT STEPS 06 Failed codes 15 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 08/25/2025 @ 12:10 $80 annual inspection fee BRAD BALDWIN - 08/2512025 @ 12:23 Fire extinguishers due for annual service December 2025. BRAD BALDWIN - 08/25/2025 @ 12:28 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - CeII: 319-230-1224 Reinspection Date 09/19/2025 BRAD BALDWIN - 08/25/2025 @ 12:28 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 08/2512025 @ 12:28 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Jael Arceo owner 2025 Date: BRAD BALDWIN 08/2512025 CHECKLISTS GENERATED ON 8/25/25, 12:31 PM 1 OF 4 Electrical Safety Status rode Fail Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Description Location: Kitchen bathroom Comments: Provide missing cover to outlet. Location: Near ATM Comments: Remove yellow 3-way multi -plug adapter. May replace with power strip with manual reset plugged to wall outlet properly mounted or supported, use only for light duty electric. Location: Outdoor seating Comments: Remove white multi -plug extension cord from exterior lighting. Location: Tea drink station Comments: Multi -plug cord and multi -plug adapter shall be removed. May replace with power strip with manual reset, properly mounted or supported for Tight duty electric. Appliances shall be plugged directly to wall outlet. GENERATED ON 8/25/25, 12:31 PM 2 OF 4 Additional Codes Status Code Fail 606.2 - Where required. A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exceptions: 1.Factory-built commercial exhaust hoods that are listed and labeled in accordance with UL 710, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B, and installed in accordance with Section 304.1 of the International Mechanical Code, shall not be required to comply with Sections 507.1.5, 507.2.3, 507.2.5, 507.2.8, 507.3.1, 507.3.3, 507.4 and 507.5 of the International Mechanical Code. Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code. For the purpose of determining the floor area required to be ventilated, each individual appliance shall be considered as occupying not less than 100 square feet (9.3 m2). 3.Where cooking appliances are equipped with integral down -draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96, a hood shall not be required at or above them. 4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mglm3 or less of grease when tested at an exhaust flow rate of 500 cfm (0.236 m3ls) in accordance with UL 710B. Fire Resistant Construction Maintenance status Fail Code 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions, Description Location: Single burner range Comments: Relocate cooking equipment producing grease laden vapors to be within 6 inches inside of outer edges of hood exhaust system. Description Location: Kitchen office Comments: Install missing ceiling tiles to maintain fire protection. GENERATED ON 8/25/25, 12:31 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee N/A $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number NIA N/A GENERATED ON 8/25/25, 12:31 PM 4 OF 4