Loading...
HomeMy WebLinkAbout840-844 W 4TH STCustomer #: 9015 TRI-COUNTY CHILD & FAMILY PO BOX 1050 WATERLOO, IA 50704 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 09/05/2025 10/15/2025 2026-00000117 $80.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed:• DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 840-844 W 4TH ST - 8-28-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 9015 09/05/2025 10/15/2025 2026-00000117 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Tri-County Child & Family Development Council - 840 - 844 W 4th ST, BLDG 844 W 4th st, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 08/28/2025 Lead Inspector JEREMIAH VANDYKE Inspection Type Annual Inspection (1Yr) c�5 Other Inspectors NIA 425 E. 3rd Street Inspection Number 15480 Shift Station Unit N/A N/A NIA SUMMARY OF INSPECTION 059 06 Q8 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 08/28/2025 @ 12:27 Fire Extinguisher serviced by Hawkeye Fire and Safety October 2024. JEREMIAH VANDYKE - 08/28/2025 @ 12:28 Dryers cleaned by Harris Cleaning 3/11/2025. JEREMIAH VANDYKE - 08/28/2025 @ 12:29 Discussed the use of space heaters. Reinspection Date 09/27/2025 JEREMIAH VANDYKE - 08/28/2025 @ 12:47 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. "**"*Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 08/28/2025 @ 12:47 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 08/28/2025 @ 12:48 Inspection Fee = $80.00 (To be mailed out by City via snail mail) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 8/28/25, 12:49 PM 1 OF 4 Pauline Jones Date: CHECKLISTS Means of Egress Status Code Fail 1010.1.3 - Door opening force Forces to unlatch and open doors. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors, as well as sliding and folding doors, the door latch shall release when subjected to a 15-pound (67 N) force. The door shall be set in motion when subjected to a 30-pound (133 N) force. The door shall swing to a full -open position when subjected to a 15-pound (67 N) force. The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull, the operational force to unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where door hardware operates by rotation, the operational force to unlatch the door shall not exceed 28 inch -pounds (315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated, other than doors required to be fire rated, the force for pushing or pulling open the door shall not exceed 5 pounds (22 N). 2.For other swinging doors, sliding doors or folding doors, and doors required to be fire rated, the door shall require not more than a 30-pound (133 N) force to be set in motion and shall move to a full -open position when subjected to not more than a 15-pound (67 N) force. Emergency Equipment Status Code Fail Documentation 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Sidles code Fail 405.6 - Recordkeeping. Records shall be maintained of required emergency evacuation drills and include the following information: 1.ldentity of the person conducting the drill. 2.Date and time of the drill. 3.Notification method used. 4.Employees on duty and participating. 5.Number of occupants evacuated. 6.Special conditions simulated. 7.Problems encountered. 8.Weather conditions when occupants were evacuated. 9.Time required to accomplish complete evacuation. Descriptio/ Location: Door #4 double doors. Comments: 1 side of the double doors would not open. Need to repair. Description Location: South side basement area. Comments: Multiple egress lights in basement failed. Will be repairing or replacing. Description Location: Fire drill needs to be done and recorded. Comments: Fire drill needs to be done and recorded. GENERATED ON 8/28/25, 12:49 PM 2 OF 4 Electrical Safety Status Code Fail Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Fire Resistant Construction Maintenance Status Fail Description Location: South basement near Safe room in hallway. Comments: Open electrical box hanging through open ceiling grid. Location: Nurses station. Comments: Daisy chanined powerstrips need to be removed. Need to remove. Code Description 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof!ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: 1st floor and basement. Comments: Multiple ceiling tiles are missing and will be replaced after roof leaks are addressed. Roof is currently under construction. GENERATED ON 8/28/25, 12:49 PM 3 OF 4 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number N/A Date Paid Amount Paid Check Number Transaction Number N/A N/A GENERATED ON 8/28/25, 12:49 PM 4 OF 4