Loading...
HomeMy WebLinkAbout225-229 E 4TH STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/22/2025 01/09/2026 2026-00000169 $80.00 Customer #: 24517 THE NEXT LEVEL 229E 4TH ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 225-229 E 4TH ST - 10-13-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # 24517 BILLING DATE 10/22/2025 DUE DATE 01/09/2026 INVOICE # 2026-00000169 CHARGES $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report The Next Level - 225 - 229 E 4th ST, BLDG 225 - 229 E 4th St, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 10/1312025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A 425 E. 3rd Street Inspection Number 14859 Shift Station Unit N/A NIA NIA SUMMARY OF INSPECTION 0 57 Passed codes NEXT STEPS 0 8 Failed codes 11 NIA codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 10/13/2025 @ 15:04 $80 annual inspection fee BRAD BALDWIN - 10/15/2025 @ 10:29 Fire extinguishers due annually serviced in September 2026 BRAD BALDWIN - 10/15/2025 @ 10:33 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 1111212025 BRAD BALDWIN - 10115/2025 @ 10:33 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violationsiand hazards corrected BRAD BALDWIN - 10/15/2025 @ 10:33 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection LSF,. Bobbie Mabry Date: BRAD BALDWIN 10115/2025 CHECKLISTS GENERATED ON 10/15/25, 1035 AM 1 OF 5 Emergency Equipment Status; Code Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. General Housekeeping Status Code Fail 305.1 - Clearance from ignition sources. 0 Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained in an approved manner. Additional Codes Status Code Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. Description Location: Bottom of stairs in basement Comments: Repair or replace egress lighting that failed to illuminate during testing. Description Location: Kitchen Comments: Repeat violation: Remove curtains near flat top grill or provide documentation of fire proof material. Description Location: Basement Comments: Chains for securing CO2 tanks shall be secured to wall framing for more stability to avoid tip over hazard. GENERATED ON 10/15/25, 10:35 AM 2 OF 5 Electrical Safety Status Code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. l`./ Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch Comments: Junction box on bottom of floor joist loose cover shall be and electrical outlet boxes. corrected. Description Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. QOpen junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Basement Location: Basement behind fridge Comments: Install proper outlet cover that is missing. Location: VIP area Comments: Install proper outlet cover that is missing. GENERATED ON 10/15/25, 10:35 AM 3 OF 5 Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Portable Fire Extingusihers St ius Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: VIP area DJ booth Comments: Remove extension cord and power strip from another power strip. Power strips shall be plugged directly to wall outlet, used for light duty electric only. Description Location: Basement Comments: Remove old fire extinguisher from building GENERATED ON 10/15/25, 10:35 AM 4 OF 5 Statement of Fees FEE Invoice Date N/A Invoice Number NIA Inspection Fee $80.00 Date Paid Amount Paid Check Number NIA Transaction Number NIA GENERATED ON 10/15/25, 10:35 AM 5 OF 5