HomeMy WebLinkAbout250 ANSBOROUGH AVEINVOICE DATE '
DUE DATE
INVOICE #
TOTAL DUE
10/22/2025
01/09/2026
2026-00000168
$100.00
Customer #: 24040
HIPPODROME AUDITORIUM
250 ANSBOROUGH AVE
WATERLOO, IA 50701
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City ClerWAccounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 250 ANSBOROUGH AVE - 10-8-25
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION 1
Total Price
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24040
10/22/2025
01/09/2026
2026-00000168
$100.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Hippodrome Auditorium - 250 Ansborough AVE, BLDG 257 Ansborough Ave,
Waterloo IA 50701
INSPECTION DETAILS
Inspection Date
10108/2025
Lead Inspector
BRAD BALDWIN
Inspection Type
Complaint REINSPECTION
Other Inspectors
NIA
425 E.3rd Street
Inspection Number
1774 -R1
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
0o
Passed codes
NEXT STEPS
01
Resolved violations
2
Failed codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 0911812025 @ 08:09
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
Reinspection Date
11/21/2025
BRAD BALDWIN - 09118/2025 @ 08:09
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 10/22/2025 @ 07:46
Phone call with Jim (10-18-25) regarding fall protection still needed.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Jim Koch
CHECKLISTS
r�
Date: BRAD BALDWIN 10/22/2025
GENERATED ON 10/22/25, 7:49 AM
1 OF 3
Reinspection
Status Code
Fail
Fail
1015.2 - Where required.
Guards shall be located along open -sided walking surfaces,
including mezzanines, equipment platforms, aisles, stairs,
ramps and landings that are located more than 30 inches (762
mm) measured vertically to the floor or grade below at any
point within 36 inches (914 mm) horizontally to the edge of
the open side. Guards shall be adequate in strength and
attachment in accordance with Section 1607.8 of the
International Building Code. Exception: Guards are not
required for the following locations: 1.On the loading side of
loading docks or piers. 2.On the audience side of stages and
raised platforms, including stairs leading up to the stage and
raised platforms. 3.On raised stage and platform floor areas,
such as runways, ramps and side stages used for
entertainment or presentations. 4.At vertical openings in the
performance area of stages and platforms. 5.At elevated
walking surfaces appurtenant to stages and platforms for
access to and utilization of special lighting or equipment.
6.Along vehicle service pits not accessible to the public. 7.In
assembly seating areas at cross aisles in accordance with
Section 1030.17.2. 8.On the loading side of station platforms
on fixed guideway transit or passenger rail systems.
9 - Complaint Field Verification
Upon visual inspection does situation match the complaints
concerns? Fail to indicate that the complaint was found to be
valid and use the codes tab to document what violations were
noted. If no violations are noted, pass and use the notes
section to indicate that no evidence of the complaints
concerns were found.
Desuitltio
Comments: Provide report from design professional for fall
protection for occupants in hot tub. Report shall be emailed to
inspector.
Additional comments: No progress made as of 10/22/25.
Comments: Electric service to hot tub installed without permit and
without fall protection. See violations for details.
Additional comments: Electric - OK.