Loading...
HomeMy WebLinkAbout1850 RIDGEWAY AVEv b A v1` t 0 0 0 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/22/2025 01/09/2026 2026-00000180 $80.00 Customer #: 23310 1850 PATIO GRILL 1850 W RIDGEWAY AVE WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1850 W RIDGEWAY - 9-25-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE Total Price $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23310 10/22/2025 01/09/2026 2026-00000180 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 1850 Patio Grill - 1850 W Ridgeway AVE, BLDG 1850 W Ridgeway Ave - STE 5, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 09/25/2025 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors NIA 425 E. 3rd Street Inspection Number 14801 Shift Station Unit NIA NIA N/A SUMMARY OF INSPECTION 056 ®10 ®10 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/2512025 @ 15:21 $80 annual inspection fee BRAD BALDWIN - 09/25/2025 @ 15:23 Fire extinguishers due annually serviced by December 2025. BRAD BALDWIN - 09/25/2025 @ 15:37 West side exterior seating christmas lights not currently plugged in. Approved for 90 day usage when in use. BRAD BALDWIN - 09/30/2025 @ 10:21 Superior serviced hood Suppression serviced June 2025 BRAD BALDWIN - 09/30/2025 @ 10:22 AKA serviced hood exhaust cleaning June 2025 BRAD BALDWIN • 09130/2025 @ 10:55 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 10/23(2025 BRAD BALDWIN - 09/30/2025 @ 10:55 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 09/30/2025 @ 10:55 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. SIGNATURES Contact signature Inspector signature GENERATED ON 9/30/25, 11:07 AM 1 OF 8 No signature Report completed post inspection Marcus Phillips 2025 Date: CHECKLISTS BRAD BALDWIN 09130/2025 Means of Egress Status erode Description Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be Location: Kitchen exit door continuously maintained free from obstructions or Comments: Remove obstructions to exit path, maintain clear egress impediments to full instant use in the case of fire or other at all times. emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. GENERATED ON 9/30/25, 11:07 AM 2 OF 8 Fire Service Features Status Cede Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Additional Codes Status Cade Fail Fail 5303.5.3 - Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or similar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1.1 - Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. Description Location: Near back door to patio seating Comments: Relocate plant in front of alarm pull station. Description Location: Bar Comments: Secure compressed gas cylinders with chain to avoid tip over. Location: Outdoor seating string lights Comments: Provide documentation of proper listing of light fixtures. GENERATED ON 9/30/25, 11:07 AM 3 OF 8 Electrical Safety Status code Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: North outdoor seating outlets Comments: Provide proper covers to outlet boxes GENERATED ON 9/30/25, 11:07 AM 4 OF 8 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Kitchen mechanical room Comments: Remove tubs from room, maintain 36" clearance in front of panels at all times for emergency access. GENERATED ON 9/30/25, 11:07 AM 5 OF 8 Fail 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: North patio seating Comments: Remove green cube style multi -plug adapter. Location: North patio seating Comments: Flexible wiring to string lights concealed in ceiling shall be removed from concealed spaces. Extension cords allowed for temporary use only. Permanent wiring shall be installed by licensed electrical contractor with obtaining permit and inspection. GENERATED ON 9/30/25, 11:07 AM 6 OF 8 Fire Resistant Construction Maintenance Status Coda Fail Fail 704.1- Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Description Location: Kitchen mechanical room Comments: Replace missing ceiling tile above water heater. Location: Front vestibule Comments: Replace missing ceiling tiles. GENERATED ON 9/30/25, 11:07 AM 7 OF 8 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 9/30/25, 11:07 AM 8 OF 8