Loading...
HomeMy WebLinkAbout2046 SOVIA DRINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/22/2025 01/09/2026 2026-00000166 $100.00 Customer #: 23043 FREDDY'S 2046 SOVIA DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2046 SOVIA DR - 10-10-25 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 23043 10/22/2025 01/09/2026 2026-00000166 $100.00 Less Prepayment Total Due —� City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Freddy's - 2046 Sovia DR, BLDG 2046 Sovia Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type 10/10/2025 Annual Inspection (1Yr) REINSPECTION Lead Inspector BRAD BALDWIN Other Inspectors N/A 425 E. 3rd Street Inspection Number 1119-R2 Shift Station Unit NIA N/A N/A SUMMARY OF INSPECTION 0 0 0 5 0 4 Passed codes NEXT STEPS Resolved violations Failed codes Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09/12/2025 @ 12:25 $80 annual inspection fee BRAD BALDWIN - 09/12/2025 @ 12:25 Fire extinguishers due annually serviced by March 2026 BRAD BALDWIN - 09/12/2025 @ 12:25 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224 Reinspection Date 11/14/2025 BRAD BALDWIN - 09112/2025 @ 12:25 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 09/12/2025 @ 12:25 Complete corrections of open violations to avoid re -inspection fees. BRAD BALDWIN -10/10/2025 @ 13:43 $100 re -inspection fee, failure to make corrections as of 10/10/25 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Yolanza Chambers (2025 GM) Rr Date: BRAD BALDWIN 10/10/2025 GENERATED ON 10/10/25, 1:44 PM 1 OF 5 CHECKLISTS GENERATED ON 10/10/25, 1:44 PM 2 OF 5 Reinspection Status Code Fail Fail 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Kitchen sprinkler system Comments: Remove obstructions and maintain to clear path of access to sprinkler system. Additional comments: Remove obstructions immediately Location: West exterior light fixture Comments: Repair or replace damaged light fixture exposing wires. GENERATED ON 10/10/25, 1:44 PM 3 OF 5 Fail 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Additional Codes Status Fail 606.3.3.1 - Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Kitchen electric panels Comments: Maintain 36" clearance in front of panel and clear path for access. Description Location: Kitchen hood suppression system Comments: Provide suppression system inspection report with any deficiencies corrected. Contractor must upload report to Compliance Engine. Currently 10 days past due as of 10/10125 GENERATED ON 10/10/25, 1:44 PM 4 OF 5 =Q FEE Statement of Fees Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number NIA Check Number Transaction Number NIA NIA GENERATED ON 10/10/25, 1:44 PM 5 OF 5