Loading...
HomeMy WebLinkAbout2604 W AIRLINE HWYCustomer #: 7072 UNITED BEVERAGE 2604 W AIRLINE HWY WATERLOO, IA 50703 INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/22/2025 01/09/2026 2026-00000178 $100.00 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 2604 W AIRLINE HWY - 9-18-25 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 20,000 OCCUPANCY FEE Total Price $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 7072 10/22/2025 01/09/2026 2026-00000178 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report United Beverage Inc - 2604 W Airline HWY, BLDG 2604 W Airline Hwy, Waterloo IA 50703 INSPECTION DETAILS Inspection Date 09/18/2025 Lead inspector JEREMIAH VANDYKE Inspectooi; Type Annual Inspection (1Yr) Other Inspectors BRAD BALDWIN Shift Station NIA NIA 425 E. 3rd Street Inspection Number 181 Unit NIA SUMMARY OF INSPECTION 025 016 Q40 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 09/18/2025 @ 12:47 Fire extinguishers serviced by Proshield August 2025. Reinspection Date 10/18/2025 JEREMIAH VANDYKE - 09/18/2025 @ 13:41 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 09/1812025 @ 13:41 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 09/18/2025 (E7c 13:41 Inspection Fee = $100.00 (To be mailed out by City via snail mail.) SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Dave Burrington Date: CHECKLISTS JEREMIAH VANDYKE 09/18/2025 GENERATED ON 9/18/25, 2:03 PM 1 OF 7 Means of Egress Status :ode Fail 1010.2.5 - Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1.On doors not required for egress in individual dwelling units or sleeping units. 2.Where a pair of doors serves a storage or equipment room, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf. 3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf. The inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. 4.Where a pair of doors serves a Group B, F or S occupancy, manually operated edge- or surface -mounted bolts are permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. The inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. 5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies, self -latching edge- or surface - mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Status Code Fail Fail Fail Fail D(•rsas iption Location: Training room. Comments: Can only have 1 lock on marked exit door. Discussed keeping the thumb turn and getting rid of door knob lock. Location: Marked exit on north wall in warehouse area. Comments: Must remove obstructions in front of marked exit. Description 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress Location: Entire Building. illumination in accordance with Sections 1008.3 and 1104.5.1. Comments: All Egress and Exit lighting needs to be repaired or replaced. Discussed getting licensed electrician to address lights. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. Location: Cooler Keg room. Comments: Need to have licensed electrician pull electrical permit and install egress/Exit lighting above walk through door. Location: Entire building. Comments: All Egress and Exit lighting needs to be repaired or replaced. Discussed getting licensed electrician to address lights. Location: 2nd floor sales manager area. Comments: Exit/Egress lighting is needed in hallway leading to the sales office exit door. Exit light needed above door leading out to steps. Total of 2 exit/egress lighting. Licensed electrician will need to pull electrical permit and install proper exit/egress lighting. GENERATED ON 9/18/25, 2:03 PM 2 OF 7 Documentation Status Cod Fail 407.2 - Safety Data Sheets. Safety Data Sheets (SDS) for all hazardous materials shall be either readily available on the premises as a paper copy, or where approved, shall be permitted to be readily retrievable by electronic access. Additional Codes Status Fail Code 5003.5 - Hazard identification signs. Unless otherwise exempted by the fire code official, visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above -ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. Location: SDS sheets for flammable liquids needed for Oil and Antifreeze in building. Comments: SDS sheets for flammable liquids needed. Description Location: NFPA 704 permanent Placarding needed on outside of building on 3 sides. Comments: Please refer to the MSDS sheets that came with the oil and antifreeze to get proper numbering. Please refer to the NFPA 704 cheat sheet on proper sizing of placard. Please contact me on locations and help on the placards. GENERATED ON 9/18/25, 2:03 PM 3 OF 7 Electrical Safety Slates Code Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. DeScoptioPI Location: North east garage door. Comments: Broken out outlet that needs repaired or replaced. Location: Hotsy electrical cord. Comments: Hotsy power washer cord needs to be moved. Cannot run cord through garage door rails. Discussed getting an licensed electrician to pull permit to move plug in for hotsy. GENERATED ON 9/18/25, 2:03 PM 4 OF 7 Fail Fail Fail Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.5 - Relocatable power taps and current taps.Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. The construction and use of current taps and relocatable taps shall be in accordance with NFPA 70 and this code. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Outside northwest corner white electrical cord. Comments: Remove white cord going to roof. Location: Michaels office both desk in room have refridgerators plugged into power strips. Comments: Refridgerators must be plugged directly into wall outlet and not into power strips. Location: Upstairs back sales manager office. Comments: Under desk has extension cord plugged into power strip. Can not use extension cords as permanent wiring and power strip needs to by plugged directly into wall outlet. Location: Shrink wrap maching has orange extension cord being used as permanent wiring. Orange extension cords is also plugged into powerstrip. Comments: Must have licensed electrician pull electrial permit and install correct outlet and wiring for shrink wrap machine. GENERATED ON 9/18/25, 2:03 PM 5 OF 7 Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Fire Resistant Construction Maintenance Status Code Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floorlceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Shop water heater water pump. Comments: Orange extension cord being used as permanent wiring. Need remove extension cord and install correct wiring and outlet by licensed electrician. Description Location: 1. Drivers's Bathroom above toilet. 2. Training room bathroom. 3. 2nd floor back sales office room. Comments: Ceiling tiles need to be replaced. GENERATED ON 9/18/25, 2:03 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee NIA $100.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 9/18/25, 2:03 PM 7 OF 7