Loading...
HomeMy WebLinkAbout1155 DIXONINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/21/2025 11/25/2025 2026-00000017 $50.00 Customer #: 24822 KEL-MAR LC 2843 GERALDINE RD WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN:: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1155 DIXON - 10-7-25 FOR BILLING INQUIRY: (319)291-4323 Description REINSPECTION FEE 1ST Total Price $50.00 CUSTOMER # 24822 BILLING DATE 10/21/2025 DUE DATE 11/25/2025 INVOICE # 2026-00000017 CHARGES $50.00 Less Prepayment Total Due —* City of Waterloo $0.00 $50.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Kel-Mar LC - 1155 Dixon DR, Waterloo IA 50701-4785 INSPECTION DETAILS Inspection Date 10/07/2025 Lead lnspector BARRY STRATTON Inspection Type Rental Inspection REINSPECTION Other Inspectors NIA 425 E. 3rd Street Inspection Number 17218-R3 Shift Station Unit N/A NIA N/A SUMMARY OF INSPECTION 0 0 0 2 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: BARRY STRATTON barry.stratton@waterloo-ia.org, 3199611280 SIGNATURES Contact signature Inspector signature Danielle Morris CHECKLISTS Reinspection Date 11104/2025 10/07/2025 BARRY STRATTON 10/07/2025 GENERATED ON 10/7/25, 6:50 AM 1 OF 3 Reinspection Status Code Description Fail 703.1 - Maintaining protection. Materials and firestop systems used to protect membrane and through penetrations in fire -resistance -rated construction and construction installed to resist the passage of smoke shall be maintained. The materials and firestop systems shall be securely attached to or bonded to the construction being penetrated with no openings visible through or into the cavity of the construction. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1 - Maintaining protection. Where required when the building was originally constructed, materials and systems used to protect joints and voids in the following locations shall be maintained. The materials and systems shall be securely attached to or bonded to the adjacent construction, without openings visible through the construction. 1.Joints in or between fire -resistance -rated walls, floors or floor/ceiling assemblies and roof or roof/ceiling assemblies. 2.Joints in smoke barriers. 3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall. 4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall. 5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall. 6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall. 7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed. Where the system design number is known, the system shall be inspected to the listing criteria and manufacturer's installation instructions. Location: Fire door closures not in working condition. Doors maintained in open position. Location: Fire doors GENERATED ON 10/7/25, 6:50 AM 2 OF 3 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $50.00 Invoice Number N/A Check Number Transaction Number NIA NIA GENERATED ON 10/7/25, 6:50 AM 3 OF 3