HomeMy WebLinkAbout1139 DIXONINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
10/21/2025
11/25/2025
2026-00000015
$50.00
Customer #: 24822
KEL-MAR LC
2843 GERALDINE RD
WATERLOO, IA 50703
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 1139 DIXON - 10-7-25
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION FEE 1ST
Total Price
$50.00
CUSTOMER #
24822
BILLING DATE
10/21/2025
DUE DATE
11/25/2025
INVOICE #
2026-00000015
CHARGES
Less Prepayment
Total Due —�
City of Waterloo
$50.00
$0.00
$50.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Kel-Mar LC - 1139 Dixon DR, Waterloo IA 50701-4783
INSPECTION DETAILS
Inspection Date
10/07/2025
Lead Inspector
BARRY STRATTON
Inspection Type
Rental Inspection REINSPECTION
Other Inspectors
NIA
425 E.3rd Street
Inspection Number
17222-R3
Shift Station Unit
N/A NIA NIA
SUMMARY OF INSPECTION
0
Passed codes
NEXT STEPS
4
Failed codes
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
BARRY STRATTON - 10/07/2025 @ 06:39
304.12: Handrail on 1st floor back stairs bracket is loose.
SIGNATURES
Contact signature Inspector signature
6____Jk4/1/1_
Danielle Morris
CHECKLISTS
Reinspection Date
11/04/2025
10/07/2025 BARRY STRATTON 10/07/2025
GENERATED ON 10/7/25, 6:42 AM
1 OF 3
Reinspection
Status Code Description
Fail 703.1 - Maintaining protection.
Materials and firestop systems used to protect membrane and
through penetrations in fire -resistance -rated construction and
construction installed to resist the passage of smoke shall be
maintained. The materials and firestop systems shall be
securely attached to or bonded to the construction being
penetrated with no openings visible through or into the cavity
of the construction. Where the system design number is
known, the system shall be inspected to the listing criteria
and manufacturer's installation instructions.
Fail 704.1- Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Fail 907.2.11 - Single- and multiple -station smoke alarms.
Listed single- and multiple -station smoke alarms complying
with UL 217 shall be installed in accordance with Sections
907.2.11.1 through 907.2.11.7 and NFPA 72.
Fail R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
Location: Fire door closures not working. Doors held in open
position.
Location: Fire doors
Location: Smoke detectors need to be in working condition.
Location: Peeling paint on 2nd floor on wall separating apartments
GENERATED ON 10/7/25, 6:42 AM
2 OF 3
Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $50.00
Invoice Number
N/A
Check Number Transaction Number
NIA NIA
GENERATED ON 10/7/25, 6:42 AM
3 OF 3