RENTAL INSPECTION - 132 LOBDELL - 10-7-25
FOR BILLING INQUIRY: (319)291-4323
Description
REINSPECTION FEE 3RD
Total Price
$250.00
CUSTOMER #
24800
BILLING DATE
10/21/2025
DUE DATE
11/25/2025
INVOICE
2026-00000021
CHARGES
$250.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$250.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
132 Lobdell RD, Waterloo IA 50701-1102
INSPECTION DETAILS
Inspection Date
10107/2025
Lead Inspector
BARRY STRATTON
Inspection Type
Rental inspection REINSPECTION )
Other lnspectors
NIA
IZslunAc01—ipo
�a�y
'O �� 425 E. 3rd Street
sP0A064-4)c)
Inspection Number
16444-R4
Shift Station Unit
NIA NIA NIA
SUMMARY OF INSPECTION
0 0 0 10
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
Reinspection Date
11/04/2025
BARRY STRATTON - 10/07/2025 @ 07:05
Plumbing details: Several corrections noted during inspection, a licensed plumbing contractor shall obtain proper permitslinspections to correct any
deficiencies. Corrections include but may not be limited to: (1) Main floor bathroom sink drain, flexible drainage piping shall be replaced. (2) Water heater
installed without permit/inspection. (3) Mechanical room sink drainage/vent piping installed not to plumbing code shall be corrected. (4) Laundry
drainage/vent piping installed not to plumbing code shall be corrected.
BARRY STRATTON - 10/0712025 @ 07:05
Electrical details: Several corrections noted during inspection, a licensed electrical contractor shall obtain proper permits/inspections to correct any
deficiencies. Corrections include but may not be limited to: (1) Several open electrical boxes noted in basement without covers. Wires not landed in
boxes. (2) Lighting fixture noted in basement stoop unfixed, laying on shelf. (3) Electrical serving furnace, water heater & laundry installed without
permits/inspections. (4) Outletslswitches missing appropriate covers. (5) main floor SW bedroom, outlet below window failed tester due to "open
ground". (6) Loose wiring noted in basement shall be stapled. (7) Service mast tie down cable connected to chain, nailed to wood post shall be corrected.
BARRY STRATTON - 10/07/2025 @ 07:05
-Re-inspection date is as posted on the inspection report given, the rental unit's responsible person/s shall reach out prior to set time of that re -
inspection. If all corrections are made before the scheduled inspection, you can call to set up an earlier re -inspection. Appropriate notices shall be given
to occupants of the unitls. Owner or owner's agent must be present during inspections. Failure to schedule a time on the date given or failure to keep the
inspection will result in a $100 fee. *****Re inspection fees may be assessed for re -inspections. Re -inspection fees start at $50, then $150, and $250 for all
subsequent re -inspections. All appropriate keys to gain entry to locked units shall be readily available during re -inspection.
BARRY STRATTON - 10/07/2025 @ 07:05
Therese/Kevin (tenant & relative of owner) will be representative for owner during re -inspection. 641-751-1486
BARRY STRATTON - 10/07/2025 @ 07:06
No permits have been obtained for the required corrections noted from previous inspectors reports.
SIGNATURES
Contact signature Inspector signature
GENERATED ON 10/7/25, 7:07 AM 1 OF 5
Don Reinholdt 10107/2025
CHECKLISTS
GENERATED ON 10/7/25, 7:07 AM 2 OF 5
Reinspection
Status Code
Fail
Fail
Fail
Fail
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
907.2.11.2 - Groups R-2, R-3, R-4 and 1-1.
Single- or multiple -station smoke alarms shall be installed
and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2.In each room used for
sleeping purposes. 3,1n each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level.
907.2.11.2 - Groups R-2, R-3, R-4 and 1-1.
Single- or multiple -station smoke alarms shall be installed
and maintained in Groups R-2, R-3, R-4 and 1-1 regardless of
occupant load at all of the following locations: 1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms. 2.In each room used for
sleeping purposes. 3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels, a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level.
915.2.1 - Dwelling units.
Carbon monoxide detection shall be installed in dwelling
units outside of each separate sleeping area in the immediate
vicinity of the bedrooms. Where a fuel -burning appliance is
located within a bedroom or its attached bathroom, carbon
monoxide detection shall be installed within the bedroom.
R6 - Interior Structure
Has the interior of the structure and equipment inside been
maintained in good repair, structurally sound, and in a
sanitary condition? (IPMC 305)
Description
Location: Several electrical deficiencies
Comments: See notes for further details
Location: Bedroom #1
Comments: Lack of smoke detector in bedroom. Smoke detectors
with proper UL listing required installed in accordance to
manufactures guidelines in bedrooms and in good working condition
Location: Bedroom #2
Comments: Lack of smoke detector in bedroom. Smoke detectors
with proper UL listing required installed in accordance to
manufactures guidelines in bedrooms and in good working condition
Location: Main floor near bedrooms
Comments: Smoke/Carbon monoxide detector failed testing. Repairs
or replacement of detector shall be made.
Location: Basement stairway
Comments: 307.1 General. Every exterior and interior flight of stairs
having more than four risers shall have a handrail on one side of the
stair and every open portion of a stair, landing, balcony, porch, deck,
ramp or other walking surface that is more than 30 inches (762 mm)
above the floor or grade below shall have guards. Handrails shall be
not less than 36 inches (762 mm) in height or more than 42 inches
(1067 mm) in height measured vertically above the nosing of the
tread or above the finished floor of the landing or walking surfaces.
Guards shall be not less than 30 inches (762 mm) in height above the
floor of the landing, balcony, porch, deck, or ramp or other
GENERATED ON 10/7/25, 7:07 AM 3 OF 5
Fail R6.C. - Mechanical Eqiupment
Are mechanical appliances properly installed and maintained
in good working condition? (IPMC 603.1)
Fail R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Fail R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Fail
R6.E. • Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Fail R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Furnace
Comments: Furnace installed without permit & inspection shall be
corrected. Licensed HVAC contractor shall obtain proper
permits/inspections to correct any deficiencies.
Location: Main floor bathroom
Comments: Shower walls not water -tight shall be corrected.
Loose/flaking paint on wall surfaces shall be corrected.
Location: Several plumbing issues
Comments: See notes for further details.
Location: Mechanical room floor drain
Comments: Drain cover obstructed shall be cleared to allow flow of
drainage.
Location: Main floor bathroom toilet
Comments: Toilet failed to flush, shall be corrected.
GENERATED ON 10/7/25, 7:07 AM
4 OF 5
Statement of Fees
FEE
Invoice Date
NIA
Invoice Number
NIA
Inspection Fee Date Paid Amount Paid
$250.00
Check Number Transaction Number
N/A NIA
GENERATED ON 10/7/25, 7:07 AM 5 OF 5
INVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
10/21/2025
11/25/2025
2026-00000025
$150.00
Customer #: 24799
JH REAL ESTATE GROUP
153 PARKWOOD
FORT DODGE, IA 50501
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 628 SYCAMORE - 9-23-25
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION FEE 2ND
$150.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24799
10/21/2025
11/25/2025
2026-00000025
$150.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
628 Sycamore St - 630 Sycamore ST, BLDG 630 Sycamore St - STE 2, Waterloo IA
50703
INSPECTION DETAILS
Inspection Date Inspection Type
0912312025 Rental Inspection
Lead Inspector
BARRY STRATTON
REINSPECTION
Other inspectors
NIA
Shift
NIA
Station
NIA
\-0qc1 Rp1/4KoJ x--
rb (,L r
tak,wocd cV
sp is ri C)AC\OC
17255-R2
Unit
NIA
SUMMARY OF INSPECTION
0 0 7
passed codes codes
NEXT STEPS
Please direct questions about your Inspection to:
BARRY STRATTON
barry.stratton@waterloo-ia.org, 3199611280
GENERAL NOTES
BARRY STRATTON - 0912312025 @ 10:41
Reinspection Date
10114/2025
304.15Exterior doors, door assemblies, operator systems, and hardware shall be maintained in good condition. Locks on means of egress shall be in
accordance with Section 702.3 --- Front door hardware malfunctioning and window and trim holding window in is broken.
SIGNATURES
Contact signature
CPV\A__
JH Real Estate Group LLC
CHECKLISTS
Inspector signature
0912312025 BARRY STRATTON
09123/2025
GENERATED ON 9/23/25, 10'43 AM 1 OF 4
Reinspection
.-status Code
Fail
Fail
Fail
Fail
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
703.1 - Maintaining protection.
Materials and firestop systems used to protect membrane and
through penetrations in fire -resistance -rated construction and
construction installed to resist the passage of smoke shall be
maintained. The materials and firestop systems shall be
securely attached to or bonded to the construction being
penetrated with no openings visible through or into the cavity
of the construction. Where the system design number is
known, the system shall be inspected to the listing criteria
and manufacturer's installation instructions.
705.2 - Inspection and maintenance.
Opening protectives in fire -resistance -rated assemblies shall
be inspected and maintained in accordance with NFPA 80.
Opening protectives in smoke barriers shall be inspected and
maintained in accordance with NFPA 80 and NFPA 105.
Openings in smoke partitions shall be inspected and
maintained in accordance with NFPA 105. Fire doors and
smoke and draft control doors shall not be blocked,
obstructed, or otherwise made inoperable. Fusible links shall
be replaced promptly whenever fused or damaged. Opening
protectives and smoke and draft control doors shall not be
modified.
901.6 - Inspection, testing and maintenance.
Fire detection and alarm systems, emergency alarm systems,
gas detection systems, fire -extinguishing systems,
mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained
in an operative condition at all times, and shall be replaced or
repaired where defective. Nonrequired fire protection and life
safety systems and equipment shall be inspected, tested and
maintained or removed in accordance with Section 901.8 .
Location: Fire separation between floors from unit 2 laundry area.
Location: Laundry room fire separation between apartment and
commercial space.
Location: Floor system between residential and commercial space.
Location: Egress light at top of stairs broken. Need Fire Extinguisher
in units. Fire separation between floors of commercial business and
apartments needs to meet fire code. Hole between floors.
GENERATED ON 9/23/25, 10:43 AM 2 OF 4
Fail
Fail
Fail
906.1 - Where required.
Portable fire extinguishers shall be installed in all of the
following locations: 1.1n new and existing Group A, B, E, F, H,
1, M, R-1, R-2, R-4 and S occupancies. Exceptions: 1.In Group
R-2 occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
dwelling unit is provided with a portable fire extinguisher
having a minimum rating of 1-A:10-B:C. 2.In Group E
occupancies, portable fire extinguishers shall be required
only in locations specified in Items 2 through 6 where each
classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C. 3. In storage areas of Group
S occupancies where forklift, powered industrial truck or
powered cart operators are the primary occupants, fixed
extinguishers, as specified in NFPA 10, shall not be required
where in accordance with all of the following: 3.1. Use of
vehicle -mounted extinguishers shall be approved by the fire
code official. 3.2. Each vehicle shall be equipped with a 10-
pound, 40A:80B:C extinguisher affixed to the vehicle using a
mounting bracket approved by the extinguisher manufacturer
or the fire code official for vehicular use. 3.3. Not less than
two spare extinguishers of equal or greater rating shall be
available on -site to replace a discharged extinguisher. 3.4.
Vehicle operators shall be trained in the proper operation, use
and inspection of extinguishers. 3.5. Inspections of vehicle -
mounted extinguishers shall be performed daily. 2.Within 30
feet (9144 mm) distance of travel from commercial cooking
equipment and from domestic cooking equipment in Group I-
1; 1-2, Condition 1; and R-2 college dormitory occupancies.
3.In areas where flammable or combustible liquids are stored,
used or dispensed. 4.On each floor of structures under
construction, except Group R-3 occupancies, in accordance
with Section 3316.1. 5.Where required by the sections
indicated in Table 906.1. 6.Special-hazard areas, including but
not limited to laboratories, computer rooms and generator
rooms, where required by the fire code official. Exception:
Portable fire extinguishers are not required at normally
unmanned Group U occupancy buildings or structures where
a portable fire extinguisher suitable to the hazard of the
location is provided on the vehicle of visiting personnel.
907.2.11 - Single- and multiple -station smoke alarms.
Listed single- and multiple -station smoke alarms complying
with UL 217 shall be installed in accordance with Sections
907.2.11.1 through 907.2.11.7 and NFPA 72.
R6.E. - Plumbing System and Fixtures
Plumbing fixtures shall be properly installed and maintained
in working order, and shall be kept free from obstructions,
leaks and defects and be capable of performing the function
for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe, sanitary and functional
condition. (IPMC 504.1)
Location: Fire Extinguisher needed in apartments.
Location: Maintain smoke detectors in working condition. Smoke
detector will need installed in hallway outside bedrooms
Location: Bathtub not draining.
GENERATED ON 9/23/25, 10:43 AM 3 OF 4
Statement of Fees
FEE
invoice Date Inspection Fee
N/A $150.00
Invoice Number
N/A
Date Paid Amount Paid
Check Number Transaction Number
N/A NIA
GENERATED ON 9/23/25, 10:43 AM
4 OF 4